MST200 Installation Guide                                                                                                                                   

8

                       

 

2 Installation 

Preparations 

This chapter describes the preparations for MST200 installation, including preparation of installation 

tools,selection of installation sites and etc.     

2.1  Preparing Installation Tools 

When installing MST200, you may need the following tools. You shall select the tools according to the actual 

situation.   

 

Table 2-1 Installation tools list 

Type 

Tools 

General tools 

Screwdriver, adjustable spanner, vice, safety belt, hard hat, power 

board (220 VAC or as required by local regulation), POE power 

injector, crimping pliers, electric soldering iron, welding wire, PVC 

insulation tape, adhesive insulation tape, strap, insulation tools  

2.2  Examining the Installation Site 

1.  The site should be located within at least a 60% range of the 1st fresnel zone without obstacles to 

provide LOS transmission, increase coverage capacity, and minimize the number of necessary 

sites. 

2.  If no LOS secured, area in NLOS area could be covered as well, but the distance of coverage and 

area of coverage are decreased; more sites are needed to provide coverage for same area than in 

the LOS scenario. 

3.  Interference must be considered in site selection. New site should avoid known interference, unless 

the interference is controllable. 

4.  Keep the MST200 away from places that are susceptible to high temperature, dust, harmful gas, 

inflammable, explosive, electromagnetic interference (high power radar, radio station and 

transformer), unstable voltage, heavy vibration, or loud noise. In engineering design, the site should 

be selected according to the network planning and technical requirements of communications 

equipment, as well as the considerations such as climate, hydrology, geology, earthquake, electric 

power, and transportation. 

Содержание AirMesh MST200

Страница 1: ...Aruba Networks MST200 Installation Guide...

Страница 2: ...empt to repair the product or replace any component Otherwise for any consequence arising out of or relating to the users attempt repair the product including but not limited to damages disuse short c...

Страница 3: ...ST200 must be installed by trained professional installation technicians All warnings below must be read and understood before installation General Safety Warnings You can be killed or injured if perf...

Страница 4: ...prevent surge and static electricity Grounding Warning Please always remember to protect your MST200 system by installation of grounding lines The ground connection must be complete before connecting...

Страница 5: ...ruba will not take any responsibility for such damage For RF module with power less than 100mW in test environment it is allowed worked without load but should be within 30 minutes Protection on unuse...

Страница 6: ...easures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receive...

Страница 7: ...VIEW 7 1 1 INTERFACES 7 2 INSTALLATION PREPARATIONS 8 2 1 PREPARING INSTALLATION TOOLS 8 2 2 EXAMINING THE INSTALLATION SITE 8 3 MST200 INSTALLATION 9 3 1 INSTALLING MST200 ON A POLE 9 3 2 GROUNDING T...

Страница 8: ...MST200 Installation Guide 7 1 Product Overview 1 1 Interfaces Figure 1 1 Interfaces on MST200 1 Ethernet interface POE 2 USB console interface 3 Grounding hole...

Страница 9: ...e 1st fresnel zone without obstacles to provide LOS transmission increase coverage capacity and minimize the number of necessary sites 2 If no LOS secured area in NLOS area could be covered as well bu...

Страница 10: ...llation flowchart of MST200 3 1 Installing MST200 on a pole The mounting assembly for installing MST200 concludes a pair of pole anchors a positioning bracket a mounting bracket and bolts MST200 can b...

Страница 11: ...MST200 will be mounted Note If using M8 x150 long bolts not provided in the box shipped with MST200 the MST200 can be mounted on a pole with 96mm diameter Figure 3 1 the mounting assembly 1 a pair of...

Страница 12: ...at washer spring washer x2 4 M8 x110 bolt flat washer spring washer nut x4 Step 1 Fasten the positioning bracket onto the back of the MST200 using the five M6 x 12 bolts with flat and spring washers T...

Страница 13: ...uide 12 Step 2 Use the two M8 x 16 bolts with flat washers and spring washers to fasten the positioning bracket flanges to the mounting bracket flanges Figure 3 4 Positioning bracket and mounting brac...

Страница 14: ...e the four M8 x 110 bolts with flat washers spring washers and nuts and two pole anchors to fasten the mounting bracket to the pole The flange bolts allow the inclination of the MST200 to be adjusted...

Страница 15: ...should be less than 5 ohm and the grounding cable s cross section area should be no less than 6 mm2 The grounding hole is at the left side of the MST200 Figure 3 6 Grounding the MST200 Step 1 Peel the...

Страница 16: ...th washer 3 3 Connecting the Ethernet cable Step 1 Remove the protective cap on the Ethernet interface Step 2 Insert the Ethernet cable connector into the Ethernet interface and hand fasten the waterp...

Страница 17: ...uide 16 Note A waterproof Ethernet connector kit will be shipped with the MST200 including shielded RJ45 connector gasket mat waterproof Ethernet connector socket locknut seal ring sealing nut as show...

Страница 18: ...ation Guide 17 4 Note To log onto the MST200 via Console port use the setting as shown in table below Baud Rate 115200 Data Bits 8 Parity None Stop Bits 1 Flow Control None Default Username and Passwo...

Отзывы: