background image

 

 

MST200 Installation Guide                                                                                                                                   

1

                       

Copyright 2005-2010 by Aruba Networks, USA.    All rights reserved.   

 
 

Statement of Conditions 

 

In the interest of improving internal design, operation function, and/or reliability, Aruba Networks 
reserves the right to make changes to products described in this document without notice. Aruba 
Networks does not assume any liability that may occur due to the use or application of the product(s) 
described herein. 

 

DISCLAIMER: LIMITATION OF LIABILITY 

1

Before installation, it’s strongly recommended and requested that users pay particular attention to the 

safety warnings in the sequentially detailed operation procedures within the manual. If there’s any 

uncertainty or incapability of solving problems, contact the company’s customer support center. Please 

DO NOT incur any risk or try to verify situations by yourself. Otherwise, any consequence caused by 

the attempt shall be completely due to the user himself. 

2

Please periodically check whether the installed MST200 is damaged, worn-out or poses any danger. 

Any actual proof, sign or phenomenon of the afore-mentioned situations should be brought to the 

attention of the company at point of sale. Please DO NOT attempt to repair the product or replace any 

component. Otherwise, for any consequence arising out of or relating to the users’ attempt repair the 

product, including but not limited to damages, disuse, short circuit, fire, bodily injury, etc., the company 

shall not be liable. 

3. Users shall purchase or use the company’s MST200 voluntarily. Users shall understand on their own 

initiative and abide voluntarily by policies, regulations or laws of their respective nation or local 

territories. The consequence arising out of or relating to any violation of the local laws or regulations by 

the user, shall be solely imputed to the user himself, and the company shall not be liable. 

4. The company disclaims any and all warranties and guarantees, express, implied or otherwise, arising, 

with respect to the MST200 products or services, including but not limited to the warranty of 

merchandisability, the warranty of fitness for a particular purpose, and any warranty of non-infringement 

of the intellectual property rights of any third party. Liability of the company for loss is limited to the total 

amount paid to the company by the customer during the previous calendar year. The company will have 

no obligation or liability, whether arising in contract (including Warranty), tort (including active, passive 

or imputed negligence, strict liability or product liability) or otherwise for any special, incidental, 

Содержание AirMesh MST200

Страница 1: ...Aruba Networks MST200 Installation Guide...

Страница 2: ...empt to repair the product or replace any component Otherwise for any consequence arising out of or relating to the users attempt repair the product including but not limited to damages disuse short c...

Страница 3: ...ST200 must be installed by trained professional installation technicians All warnings below must be read and understood before installation General Safety Warnings You can be killed or injured if perf...

Страница 4: ...prevent surge and static electricity Grounding Warning Please always remember to protect your MST200 system by installation of grounding lines The ground connection must be complete before connecting...

Страница 5: ...ruba will not take any responsibility for such damage For RF module with power less than 100mW in test environment it is allowed worked without load but should be within 30 minutes Protection on unuse...

Страница 6: ...easures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receive...

Страница 7: ...VIEW 7 1 1 INTERFACES 7 2 INSTALLATION PREPARATIONS 8 2 1 PREPARING INSTALLATION TOOLS 8 2 2 EXAMINING THE INSTALLATION SITE 8 3 MST200 INSTALLATION 9 3 1 INSTALLING MST200 ON A POLE 9 3 2 GROUNDING T...

Страница 8: ...MST200 Installation Guide 7 1 Product Overview 1 1 Interfaces Figure 1 1 Interfaces on MST200 1 Ethernet interface POE 2 USB console interface 3 Grounding hole...

Страница 9: ...e 1st fresnel zone without obstacles to provide LOS transmission increase coverage capacity and minimize the number of necessary sites 2 If no LOS secured area in NLOS area could be covered as well bu...

Страница 10: ...llation flowchart of MST200 3 1 Installing MST200 on a pole The mounting assembly for installing MST200 concludes a pair of pole anchors a positioning bracket a mounting bracket and bolts MST200 can b...

Страница 11: ...MST200 will be mounted Note If using M8 x150 long bolts not provided in the box shipped with MST200 the MST200 can be mounted on a pole with 96mm diameter Figure 3 1 the mounting assembly 1 a pair of...

Страница 12: ...at washer spring washer x2 4 M8 x110 bolt flat washer spring washer nut x4 Step 1 Fasten the positioning bracket onto the back of the MST200 using the five M6 x 12 bolts with flat and spring washers T...

Страница 13: ...uide 12 Step 2 Use the two M8 x 16 bolts with flat washers and spring washers to fasten the positioning bracket flanges to the mounting bracket flanges Figure 3 4 Positioning bracket and mounting brac...

Страница 14: ...e the four M8 x 110 bolts with flat washers spring washers and nuts and two pole anchors to fasten the mounting bracket to the pole The flange bolts allow the inclination of the MST200 to be adjusted...

Страница 15: ...should be less than 5 ohm and the grounding cable s cross section area should be no less than 6 mm2 The grounding hole is at the left side of the MST200 Figure 3 6 Grounding the MST200 Step 1 Peel the...

Страница 16: ...th washer 3 3 Connecting the Ethernet cable Step 1 Remove the protective cap on the Ethernet interface Step 2 Insert the Ethernet cable connector into the Ethernet interface and hand fasten the waterp...

Страница 17: ...uide 16 Note A waterproof Ethernet connector kit will be shipped with the MST200 including shielded RJ45 connector gasket mat waterproof Ethernet connector socket locknut seal ring sealing nut as show...

Страница 18: ...ation Guide 17 4 Note To log onto the MST200 via Console port use the setting as shown in table below Baud Rate 115200 Data Bits 8 Parity None Stop Bits 1 Flow Control None Default Username and Passwo...

Отзывы: