Jumpers - Advanced Configuration 

There are several advanced settings, beyond the scope of normal operation, that can be 
accessed by fitting the supplied jumpers over the configuration pins. When viewing the product 
configuration screen in a web browser, the detailed jumper settings can be viewed in the lower 
part of the page.

The pins can be found on the bottom left of the PCB. To fit a jumper follow the instructions below:

1. 

Disconnect the Power from the unit

2. 

Ensure you have adequate Anti-Static protection

3. 

Remove the top row of screws from the front panel

4. 

Remove the bottom row of screws from the rear panel

5. 

Carefully pull the two halves apart, about 10cm

Jumper

Option

JP0

For future use

JP1

For future use

JP2

For future use

JP3

HTTP server disabled 

(e.g. no web page 

functionality)

JP4

10.x.x.x IP addressing 

active (ignored when 

DHCP is active)

JP5

RDM disabled on all 

outputs

JP6

Inverts the low byte of the 

IP address

JP7

For future use

ROM 

Boot

Switch to boot-loader 
mode on power cycle

ROM Boot Jumper

Data-Lynx O/P has boot-loader firmware programmed into its ROM. This forces the product into 
a factory ROM mode ready for firmware upload. The boot-loader firmware allows the operating 
firmware (which is stored in the flash memory) to be upgraded over the network. It is not usually 
necessary to use this procedure as firmware uploads can be initiated directly using DMX-
Workshop. 

To force Data-Lynx to start in boot-loader mode, link the ROM boot jumper and power-up the 
unit. Note that all the indicators will flash when in boot-loader mode. The firmware upgrade can 
then be made using DMX-Workshop.

If for any reason the upgrade needs to be aborted, or if the ROM boot jumper was connected in 
error, removing the jumper and powering up the unit will cause it to revert to the current installed 
firmware.

Содержание Data-Lynx O/P

Страница 1: ...Data Lynx O P User Guide Artistic Licence Version 1 8 Data Lynx O P User Guide ...

Страница 2: ... inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this product is designed for indoor use only If used outdoors it MUST be installed in an appropriate IP rated cabinet Do not allow this product to be exposed to rain or moisture Do not allow liquid to penetrate ...

Страница 3: ... Net Select 9 Data Connection Ethernet 10 11 Data Connection DMX O P 1 2 12 13 Data Connection DMX O P 3 4 14 15 Data Connection DMX O P 5 6 16 17 Data Connection DMX O P 7 8 18 19 Data Connection DMX O P 9 10 20 21 Data Connection DMX O P 11 12 22 Data Connection Ethernet 23 Replaceable Fuse Mains I P Fuse 24 Power Connection Universal Mains I P Connection ...

Страница 4: ...5 Ethercon connections one front one back The product accepts Art Net the public domain protocol invented by Artistic Licence and sACN the standard managed under ESTA PLASA E1 31 Data Lynx O P requires Cat 5 cable or better and supports 10BaseT and 100BaseT Power Supply Earthing The internal power supply requires an input in the range 90 250 VAC with an Earth connection The mains fuse should only ...

Страница 5: ...icators pictured opposite have the following meanings STAT ON when unit is powered flashing if hardware fault see Error Messages NET ON when network data is active DMX 1 2 ON when data is transmitted flashing if merging two universes see DMX Workshop Power up During power up the LEDs will step sequentially Boot loader When in boot loader mode see page 8 all the LEDs will flash continuously If all ...

Страница 6: ... output information as shown in the screen shot opposite Right clicking on any entry brings up a menu that offers various functionality y y The Configure Node option enables configuration of the Universe Sub Net and Net values It also allows the user to give the device a short and long name y y Copy to clipboard enables all the node information to be pasted into a support request email y y Merge C...

Страница 7: ...lled by a DHCP server check the Enable DHCP box to activate this feature Note that the default IP and static addressing all ports can be forced manually by the following procedure 1 Set the Sub Net wheel to 9 2 Power cycle turn off then on again 3 Power off 4 Set the Sub Net wheel to F 5 Power on IP Address Configuration Web Server To configure Data Lynx O P via the internal web server either type...

Страница 8: ...y JP4 10 x x x IP addressing active ignored when DHCP is active JP5 RDM disabled on all outputs JP6 Inverts the low byte of the IP address JP7 For future use ROM Boot Switch to boot loader mode on power cycle ROM Boot Jumper Data Lynx O P has boot loader firmware programmed into its ROM This forces the product into a factory ROM mode ready for firmware upload The boot loader firmware allows the op...

Страница 9: ...M Fault Net All alternately flashing E2Prom Fault Port 1 All alternately flashing System ROM Fault Contact Artistic Licence for advice Application Diagram PSU DMX RDM interface e g Multichrome D1 Art Net Controller e g Colour Tramp RGB Pixels Data Lynx O P Art Net DMX RDM DMX RDM In this example Data Lynx O P converts Art Net from a Colour Tramp controller into DMX RDM data This is fed into intell...

Страница 10: ... range the PC is on you must then change the PC IP address to match If you still cannot discover the device you will need to reset all custom settings to put it back into the default IP range 2 x x x All the LED indicators flash three times when I change the Sub Net wheel selector 1 If the Sub Net value has been set remotely the front panel wheel is ignored The LEDs flash to indicate this I have c...

Страница 11: ...low blow y y DC fuse internal resettable fuse for control electronics Ethernet y y Type 10 100BaseT y y Isolation 1 kV y y PoE n a DMX512 Outputs y y Output mode ground referenced y y Output isolation n a y y Output ESD protection 12 kV y y Output voltage protection 80 V y y Output conditioning slew rate limited Control y y Input Protocols Art Net sACN y y Output Protocols DMX512 DMX512 1990 DMX51...

Страница 12: ...he appropriate CE FCC and RoHS regulations Product specific information is available on request Waste Electrical Electronic Equipment WEEE Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you at your expense return to us Due to our policy of continuing product improvement specifications are subject to change without notice Artistic Licence ...

Отзывы: