Data-Lynx O/P User Guide

Art-Net II), this is achieved by setting the 
(4-bit) Universe and Sub-Net numbers (see 
‘Configuration’ below). 

In contrast, Art-Net 3 and sACN can carry up 
to 32768 and 65536 universes respectively. 
To handle these large values, the concept 
of a 16-bit port address including a ‘Net’ 
field is introduced. The port address of each 
DMX512 universe is a number composed of 
the (Net)+(Sub-Net)+(Universe). 

Note that settings made remotely override the 
wheel selector on the front panel. 

Configuration

By default, each port of the Data-Lynx O/P 
has a sequential universe number starting 
from zero. There are two ways of remotely 
configuring the product: 1) using DMX-
Workshop or 2) using the product’s internal 
web-server.

DMX-Workshop

DMX-Workshop™ is a software application 
that runs on the Windows XP & Windows 7 
platforms. It is free of charge and available via 
download from the Artistic Licence website. 

DMX-Workshop is a fully featured network 
management, analysis, configuration and 
diagnostics tool for Art-Net networks.

When Data-Lynx O/P is connected to a 
computer running DMX-Workshop, it should 
be detected and displayed as an Art-Net node 
(click the ‘Node List’ tab to verify this). 

The node can be expanded to show the 
configuration and DMX output information, as 
shown in the screen-shot opposite. 

Right-clicking on any entry brings up a menu 
that offers various functionality: 

 

y

The ‘Configure Node’ option enables 
configuration of the Universe, Sub-Net 
and Net values. It also allows the user to 
give the device a short and long name.

 

y

‘Copy to clipboard’ enables all the node 
information to be pasted into a support 
request email.

 

y

‘Merge Controls’ (selectable only on 
individual DMX outputs) enables the 
choice of LTP (latest takes preference) 
or HTP (highest takes preference) merge 
modes. 

 

y

‘Indicators’ enables selection of normal, 
locate or mute for the front panel 
LED indicators. Normal is the default 
behaviour,  locate causes the selected 
port ‘Stat’ LED to flash, and mute turns 
off all the LEDs.

 

y

‘RDM Devices’ offers options for device 
discovery on RDM networks. 

 

y

‘Advanced’ leads to ‘Programme Upload’ 
and ‘Configure IP Address’. These are 
described in more detail below.

Firmware Upgrades

The ‘Programme Upload’ option enables 
the user to upgrade the product’s firmware. 
DMX-Workshop stores the firmware files in 
C:\Program Files (x86)\Artistic Licence\DMX-
Workshop\Firmware\*.alf. 

Selection of the desired file is made via a 
pop-up window that shows the available files. 
Ensure that the firmware upgrade is applied 
to all ports (check the ‘Tick All’ box in the 
next window). Cycle the power following a 
successful firmware upload.

Note port address structure:  
(Net)-(Sub-Net)-(Universe)

DMX-Workshop Node List

Содержание Data-Lynx O/P

Страница 1: ...Data Lynx O P User Guide Artistic Licence Version 1 8 Data Lynx O P User Guide ...

Страница 2: ... inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this product is designed for indoor use only If used outdoors it MUST be installed in an appropriate IP rated cabinet Do not allow this product to be exposed to rain or moisture Do not allow liquid to penetrate ...

Страница 3: ... Net Select 9 Data Connection Ethernet 10 11 Data Connection DMX O P 1 2 12 13 Data Connection DMX O P 3 4 14 15 Data Connection DMX O P 5 6 16 17 Data Connection DMX O P 7 8 18 19 Data Connection DMX O P 9 10 20 21 Data Connection DMX O P 11 12 22 Data Connection Ethernet 23 Replaceable Fuse Mains I P Fuse 24 Power Connection Universal Mains I P Connection ...

Страница 4: ...5 Ethercon connections one front one back The product accepts Art Net the public domain protocol invented by Artistic Licence and sACN the standard managed under ESTA PLASA E1 31 Data Lynx O P requires Cat 5 cable or better and supports 10BaseT and 100BaseT Power Supply Earthing The internal power supply requires an input in the range 90 250 VAC with an Earth connection The mains fuse should only ...

Страница 5: ...icators pictured opposite have the following meanings STAT ON when unit is powered flashing if hardware fault see Error Messages NET ON when network data is active DMX 1 2 ON when data is transmitted flashing if merging two universes see DMX Workshop Power up During power up the LEDs will step sequentially Boot loader When in boot loader mode see page 8 all the LEDs will flash continuously If all ...

Страница 6: ... output information as shown in the screen shot opposite Right clicking on any entry brings up a menu that offers various functionality y y The Configure Node option enables configuration of the Universe Sub Net and Net values It also allows the user to give the device a short and long name y y Copy to clipboard enables all the node information to be pasted into a support request email y y Merge C...

Страница 7: ...lled by a DHCP server check the Enable DHCP box to activate this feature Note that the default IP and static addressing all ports can be forced manually by the following procedure 1 Set the Sub Net wheel to 9 2 Power cycle turn off then on again 3 Power off 4 Set the Sub Net wheel to F 5 Power on IP Address Configuration Web Server To configure Data Lynx O P via the internal web server either type...

Страница 8: ...y JP4 10 x x x IP addressing active ignored when DHCP is active JP5 RDM disabled on all outputs JP6 Inverts the low byte of the IP address JP7 For future use ROM Boot Switch to boot loader mode on power cycle ROM Boot Jumper Data Lynx O P has boot loader firmware programmed into its ROM This forces the product into a factory ROM mode ready for firmware upload The boot loader firmware allows the op...

Страница 9: ...M Fault Net All alternately flashing E2Prom Fault Port 1 All alternately flashing System ROM Fault Contact Artistic Licence for advice Application Diagram PSU DMX RDM interface e g Multichrome D1 Art Net Controller e g Colour Tramp RGB Pixels Data Lynx O P Art Net DMX RDM DMX RDM In this example Data Lynx O P converts Art Net from a Colour Tramp controller into DMX RDM data This is fed into intell...

Страница 10: ... range the PC is on you must then change the PC IP address to match If you still cannot discover the device you will need to reset all custom settings to put it back into the default IP range 2 x x x All the LED indicators flash three times when I change the Sub Net wheel selector 1 If the Sub Net value has been set remotely the front panel wheel is ignored The LEDs flash to indicate this I have c...

Страница 11: ...low blow y y DC fuse internal resettable fuse for control electronics Ethernet y y Type 10 100BaseT y y Isolation 1 kV y y PoE n a DMX512 Outputs y y Output mode ground referenced y y Output isolation n a y y Output ESD protection 12 kV y y Output voltage protection 80 V y y Output conditioning slew rate limited Control y y Input Protocols Art Net sACN y y Output Protocols DMX512 DMX512 1990 DMX51...

Страница 12: ...he appropriate CE FCC and RoHS regulations Product specific information is available on request Waste Electrical Electronic Equipment WEEE Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you at your expense return to us Due to our policy of continuing product improvement specifications are subject to change without notice Artistic Licence ...

Отзывы: