![Artistic License Data-Lynx O/P Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/artistic-license/data-lynx-o-p/data-lynx-o-p_user-manual_2978579011.webp)
Page 11
Data-Lynx O/P User Guide
Data-Lynx O/P Specification
CE Compliance
Data-Lynx O/P is CE compliant
Mechanical
y
Housing: 19” 1U rack enclosure
y
Material: metal
y
Overall dimensions: 1U (H) x 19” (W) x
257 mm (D)
y
Weight: 2.8 kg
y
Mounting: desktop or 19” rack (using
supplied rack ears)
y
Country of manufacture: UK
Environmental
y
Operating temperature: 0°C to 40°C
y
Storage temperature: -10°C to +50°C
y
Operating relative humidity (max): 80%
non-condensing
y
IP rating: IP20 indoor use only
y
Certification: CE, FCC, WEEE, RoHS
y
Warranty: 2-year (return to base)
Power & Electrical
y
Input voltage: 90-250 VAC
y
Input connector: IEC C13 male
y
Input power (max): 30 W
y
Duty cycle: 80% @ 25°C
y
Input fuse: 3.15A slow blow
y
DC fuse: internal resettable fuse for
control electronics
Ethernet
y
Type: 10/100BaseT
y
Isolation: 1 kV
y
PoE: n/a
DMX512 Outputs
y
Output mode: ground referenced
y
Output isolation: n/a
y
Output ESD protection: 12 kV
y
Output voltage protection: +/- 80 V
y
Output conditioning: slew-rate limited
Control
y
Input Protocols: Art-Net, sACN
y
Output Protocols: DMX512, DMX512
(1990), DMX512-A, RDM V1.0 (E1.20 -
2006 ESTA Standard)
Data Connections
y
RJ45 Ethercon (2 no.)
y
5-pin female XLR DMX outputs (12 no.)
LED Indication
y
Power / Ethernet Link / Data Activity /
Speed
Configuration
y
Remote: Web-browser, DMX Workshop
y
Manual: Wheels / Jumpers
y
Configurable settings include:
-
Net, Sub-Net, Universe
-
IP Address (DHCP), DMX profile
-
ROM boot, RDM disable
Package Contents
y
Data-Lynx O/P
y
User guide
y
IEC mains lead
y
Rack-ears
y
Jumpers (for configuration pins)
Ordering Info
y
Product code: Data-Lynx O/P