Model 8640B
TM 9-4935-601-14-7&P
Table 4-1. Performance Test Record (7 of 8)
Results
Para
Test Description
No.
Min
Actual
Max
4-38.
FM 3 dB Bandwidth Test
3 dB
4-39.
FM Distortion Test
Maximum Deviation
30.5 dB
1/8 Maximum Deviation
40 dB
4-40.
FM Sensitivity and Accuracy Test
Sensitivity: Frequency Range
256-512 MHz
1.954 kHz
2.204 kHz
128-256 MHz
1.954 kHz
2.204 kHz
64-128 MHz
1.954 kHz
2.204 kHz
32-64 MHz
1.954 kHz
2.204 kHz
16-32 MHz
1.954 kHz
2.204 kHz
8-16 MHz
1.954 kHz
2.204 kHz
4-8 MHz
1.954 kHz
2.204 kHz
2-4 MHz
1.954 kHz
2.204 kHz
1-2 MHz
1.954 kHz
2.204 kHz
0.5-1 MHz
1.954 kHz
2.204 kHz
Accuracy: Frequency Range
256-512 MHz
1.871 kHz
2.287 kHz
128-256 MHz
1.871 kHz
2.287 kHz
64-128 MHz
1.871 kHz
2.287 kHz
32-64 MHz
1.871 kHz
2.287 kHz
16-32 MHz
1.871 kHz
2.287 kHz
8-16 MHz
1.871 kHz
2.287 kHz
4-8 MHz
1.871 kHz
2.287 kHz
2-4 MHz
1.871 kHz
2.287 kHz
1-2 MHz
1.871 kHz
2.287 kHz
0.5-1 MHz
1.871 kHz
2.287 kHz
4-41.
Incidental AM Test
Maximum Deviation
1%
1/8 Maximum Deviation
0.5%
4-42.
Counter External Sensitivity Test
0.5 to 550 MHz
(
√
)
20 Hz to 500 kHz
(
√
)
20 Hz to 10 MHz
(
√
)
4-43.
Internal Reference Accuracy Test
15°C to 35°C
4,999,995 Hz
5,000,005 Hz
0°C to 55°C
4,999,985 Hz
5,000,015 Hz
4-83