Maps and Registers
ATCA-7365-CE Installation and Use (6806800L73N)
211
A write access to Telecom Timer MSB Register load the 16 bit Telecom timer with the write data
of the current access and the content of the Telecom Timer LSB Register.
6.4.23 Miscellaneous Status/Control Registers
The following table provides information about Miscellaneous Status/Control Registers.
Table 6-81 Telecom Timer MSB Register
Address Offset: 0x65
Bit
Description
Default
Access
7:0
MSB of Telecom Timer start value
PWR_GOOD: 0
LPC: r/w
Table 6-82 Telecom Timer LSB Register
Address Offset: 0x64
Bit
Description
Default
Access
7:0
LSB of Telecom Timer start value
PWR_GOOD: 0
LPC: r/w
Table 6-83 CPLD Version and Spare Signal Status Register
Address Offset: 0x6F
Bit
Description
Default
Access
2:0
CPLD Version. The CPLD uses the signals
CPLD_SPARE[3:1]
Ext.
r
3
CPLD_SPARE[4]
Ext.
r
7:4
Reserved 0
r
Содержание ATCA-7365-CE