Artel InfinityLink IL6000 Скачать руководство пользователя страница 14

IL6000 Chassis Installation and Operations Manual 

1

 

Information About the IL6000 Chassis

 

IL6000 Chassis

Media Transport Chassis

Information About the IL6000 Chassis

This manual introduces the IL6000 chassis and describes how to install and configure it. The IL6000 chassis 

features four hot swappable function module slots, dual AC power supplies, variable speed cooling fan, and 

software to provide management and switch functions.
The IL6000 chassis also includes the following features:

• 

Space-efficient rugged chassis.

• 

Controller that provides switching capabilities for interconnecting installed modules through the 

backplane. 

• 

Simple Network Management Protocol (SNMP) management.

• 

Unlimited, non-spaced installation.

Provision and monitor the IL6000 chassis as follows:

• 

Provision and monitor the chassis and installed modules remotely using Artel’s InfinityLink Manager 

(IL Manager) element management system. For more information, see the 

InfinityLink Manager Setup 

and Operations Manual

.

• 

Monitor the chassis and installed modules locally using the front and rear panel status LEDs.

Note: 

This manual uses the following terms interchangeably:

• 

Chassis and shelf when referring to the IL6000.

• 

InfinityLink Manager and IL Manager when referring to the element management system.

Содержание InfinityLink IL6000

Страница 1: ...WWW ARTEL COM Manual Installation and Operations Manual INFINITYLINK IL6000 Chassis...

Страница 2: ...ii IL6000 Chassis Installation and Operations Manual...

Страница 3: ...IL6000 Chassis Installation and Operations Manual iii Document Number AR200 006000 00_A Released December 2016 IL6000 Chassis MediaTransport Chassis Installation and Operations Manual...

Страница 4: ...iv IL6000 Chassis Installation and Operations Manual...

Страница 5: ...ness information or other pecuniary loss arising out of the use of this documentation even if ArtelVideo Systems Corporation has been made aware of the possibility of such damages Information containe...

Страница 6: ...ntially harmful levels of optical laser radiation may be present at the optical output ports and unconnected receive fiber ends Prior to applying system power connect fiber cables to either another In...

Страница 7: ...at riel brouilleur Appareils Num riques NMB 003 dict e par le Minist re des Communications This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as...

Страница 8: ...ollowing InfinityLink media platform products IL6000 to which this declaration relates is in conformity with the following standards and other normative documents Product Safety EN 60950 EMC EN55 022...

Страница 9: ...ations Manual ix Revision history for the IL6000ChassisInstallationandOperationsManual Table 0 1 Manual Revision History Revision History Revision Document Number Date Reason for Change A AR200 006000...

Страница 10: ...w 4 ILM121 Assembly Overview 6 Required InstallationTools and Equipment 6 Unpacking the IL6000 7 Ventilating the IL6000 Chassis 7 Installing the IL6000 Chassis 8 Installing the IL6000 as a Free standi...

Страница 11: ...IL6000 Chassis Installation and Operations Manual xi...

Страница 12: ...diaTransportSolutionData Sheet Product operating and environmental specifications and regulatory conformance information for the chassis InfinityLinkManagerSetupandOperations Manual Information about...

Страница 13: ...al support Outside the US call 978 263 5775 then select 1 for technical support When requesting assistance please be ready to provide the following information Your name and telephone number Product m...

Страница 14: ...hat provides switching capabilities for interconnecting installed modules through the backplane Simple Network Management Protocol SNMP management Unlimited non spaced installation Provision and monit...

Страница 15: ...rd safety practices for handling a Class 1 laser product including the following warning Warning Never stare directly into a fiber optic connector Although the light used in most fiber optic transmiss...

Страница 16: ...Warning The InfinityLink element management modules utilize an internal RTC RealTime Clock with battery backup that provides the system software with the time of day on system power up The backup batt...

Страница 17: ...le slot to cover the slot opening and maintain proper ventilation Figure 1 IL6000 Chassis Front PanelView Table 1 describes the components called out in Figure 1 Table 1 The IL6000 Chassis Front Panel...

Страница 18: ...r PanelView Table 2 describes the components called out in Figure 2 Table 2 The IL6000 Chassis Rear Panel Elements Item Description for details see Slot 1 Function module Slot 1 Installing a Function...

Страница 19: ...bly includes voltage temperature and cooling fan alarms Figure 3 ILM121 Assembly Components Table 3 describes the components called out in Figure 3 Table 3 ILM121 Assembly Components Item Description...

Страница 20: ...ion slots located on the side of the chassis near the function module slots Figure 4 shows how the fan draws air through the side of the chassis and over the function modules when power is applied The...

Страница 21: ...ts The surface must be flat clean and in a safe location The chassis must not be installed on the floor In addition to increasing the risk of being damaged placing the chassis on the floor increases t...

Страница 22: ...eration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Appropriate con...

Страница 23: ...assis mounting brackets into the threaded screw holes on the rack The chassis requires two screws for each side of the chassis mounting screws not included Figure 5 Flush Mounted Chassis Bracket Mount...

Страница 24: ...IL6000 Chassis Installation and Operations Manual 11 Installing the IL6000 Chassis Figure 6 Wall Mounted Chassis Bracket Wall Mounting Screw Holes 3...

Страница 25: ...lies connected dissipates more power that a chassis with one power supply connected due to internal power dissipation within the power supplies To connect the AC power supplies to a power source you n...

Страница 26: ...to installing them because they are configured using the DIP switches mounted to the top of the module board Other function modules must be configured after you install the module by using IL Manager...

Страница 27: ...erve the status LEDs for proper operation as described inTable 4 Table 4 IL6000 Chassis Status LEDs LED Description State Status Operating status of the chassis backplane and installed function module...

Страница 28: ...tage is present Internal failure of the power supply Replace the chassis FAN Operating status of the fan Off No power is applied to the chassis Green The fan speed is in the normal range Red The fan i...

Страница 29: ...vice If you are going to connect IL Manager to your management network you must first configure its network IP address as needed to connect to your network The chassis rear panel contains two manageme...

Страница 30: ...n Application Using the IL6000 Reset Switch The IL6000 rear panel includes a recessed push button reset switch RST that resets the chassis Resetting the chassis does not erase any user selected parame...

Страница 31: ...18 IL6000 Chassis Installation and Operations Manual...

Страница 32: ...mail address Customer Service xiii F fan ventilation 7 front panel reset switch 17 status LEDs 14 I IL Manager cabling 16 ILM121 Status page 17 overview 16 ILM121 assembly overview 6 install 8 L lase...

Страница 33: ...Index Index 2 IL6000 Chassis Installation and Operations Manual...

Страница 34: ......

Страница 35: ...lysis and design services Training and installation support available 24x7x365 technical support available Proven Products Unrivaled Service and Great Support Content subject to change without notice...

Отзывы: