background image

 

  

 

11 

 

 

 

Ordercode: A0720060 

Carlow 30 

Control Panel 

 

 

A)  LED display 
B)  Mode button 
C)  Setup button 
D)  Up button 
E)   Down button 

 
 

Fig. 05 

 

 

 

Control Mode 

The fixtures are individually addressed on a data-link and connected to the controller.  
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 
the controller will display the saved DMX address, next time.) 
 

DMX Addressing 

The control panel on the back side of the device allows you to assign DMX fixture addresses, which is the 
first channel with which the Carlow will respond to the controller. 
Please note, when you use the controller, the unit has 9 channels. 
When using multiple Carlows, make sure you set the DMX addresses right. 
Therefore, the DMX address of the first Carlow should be 1(001); the DMX address of the second Carlow 
should be 1+9=10 (010); the DMX address of the third Carlow should be 10+9=19 (019), etc. Please, be 
sure that you do not have any overlapping channels in order to control each Carlow correctly. If two or 
more Carlows are addressed similarly, they will work similarly. 
 

Controlling: 

After having addressed all Carlow fixtures, you may now start operating these via your lighting controller. 
Note:
 After switching on, the Carlow will automatically detect whether DMX 512 data is received or not.  
If not, the problem may be: 

 

The XLR cable from the controller is not connected with the input of the Carlow. 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 
swapped in the input connector. 

 
Note: 
It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 
proper transmission on the DMX data link.  
 

 

Display Off after 10 seconds

 

 

When no button is pressed for 10 seconds, the display will turn off. The fixture will switch to a lock key 
mode. To light up the display and unlock the fixture, you have to press the Mode and Down button at the 
same time for 2 seconds. Once you have pressed the buttons, the display will light up. 
 

 

Содержание Carlow 30

Страница 1: ...Carlow 30 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands ordercode A0720060 MANUAL ENGLISH...

Страница 2: ...and Static Color Mode 8 Multiple Carlows 30 Master Slave control 8 Multiple Carlows 30 DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressing 11 Menu Overview...

Страница 3: ...ng temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving the lifespan...

Страница 4: ...e power cord holding it by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is...

Страница 5: ...bed in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety a...

Страница 6: ...er 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Страница 7: ...n Programs Static dimmer DMX Master Slave Control protocol DMX 512 Dimmer 0 100 Strobe 0 20Hz Beam Angle 28 Protection rate IP 66 Housing Grey aluminum Connections Dedicated IP66 Power Data connectors...

Страница 8: ...Carlow 30 Overview Fig 01 01 3 x 10W 5 in 1 RGBWA LEDs 02 Mounting bracket Backside Fig 02 03 4 digit LED display control buttons 04 Special 3 pin power cable IN OUT IP 65 05 Special 3 pin DMX signal...

Страница 9: ...on all sides for air circulation 02 Plug the end of the electric mains power cord into a proper electric power supply socket 03 When the Carlow 30 is not connected with a DMX cable it functions as a...

Страница 10: ...ect the first unit s out socket with the second unit s in socket using the 42707 DMX Extension cable Link the second third and fourth units using the 42707 DMX Extension cable 04 Supply electric power...

Страница 11: ...dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interferen...

Страница 12: ...be sure that you do not have any overlapping channels in order to control each Carlow correctly If two or more Carlows are addressed similarly they will work similarly Controlling After having address...

Страница 13: ...12 Ordercode A0720060 Carlow 30 Menu Overview Main Menu Options Auto run Built in programs Master Slave DMX address DMX configuration Static Color Mode...

Страница 14: ...11 built in programs 04 When you select menu you can use a wide variety 19 of manual color settings Press Setup to enter and choose one with the Up Down buttons 05 Press the Setup button again to open...

Страница 15: ...u can also choose the desired DMX Mode 04 Press the Setup button to choose one of the 3 different DMX Modes Use the Up Down buttons to select 5 7 or 9 channels DMX mode Static Color control With this...

Страница 16: ...255 0 255 Gradual adjustment Red from 0 100 Channel 2 Green Dimmer intensity CH6 must be set between 001 255 0 255 Gradual adjustment Green from 0 100 Channel 3 Blue Dimmer intensity CH6 must be set b...

Страница 17: ...en 001 255 0 255 Gradual adjustment Amber from 0 100 Channel 7 Built in programs CH1 must be set between 001 255 1 24 Built in program 1 25 49 Built in program 2 50 74 Built in program 3 75 99 Built i...

Страница 18: ...ds to build up residues reducing the light output very quickly Keep connections clean Disconnect electric power and then wipe the connections with a damp cloth Make sure connections are thoroughly dry...

Страница 19: ...Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixtu...

Страница 20: ...uantity 3 x 10W 5 in 1 RGBWA LEDs Light output Red 89 3 Lm Green 243 Lm Blue 58 Lm White 206 Lm Amber 143 Lm RGBWA 587 Lm Beam angle 28 Dimmer 0 100 Strobe 0 20Hz Housing Grey aluminum DMX control via...

Страница 21: ...20 Ordercode A0720060 Carlow 30 Dimensions...

Страница 22: ...21 Ordercode A0720060 Carlow 30 Notes...

Страница 23: ...22 Ordercode A0720060 Carlow 30...

Страница 24: ...2019 Artecta...

Отзывы: