active standby
+---+ +---+ +---+
=2/1| 1 |2/4--2/1| 2 |2/4--2/4| 3 |2/1=
| +---+ +---+ +---+ |
| |
|-------------------------------------|
Standby u2 - Learn other units for 7 sec, protocols may not be ready in 63 s.
Role history: N: standalone, A: active, S: standby, M: member
U1: N->A
Current stack management MAC is cc4e.246d.9e00
ICX7750-48F Router#
After units boot up:
=====================
=================================================================
Unit 2 Logs:
=================
ICX7750-26Q Router#Unit 1 receives stack interactive-setup from U1, mac=cc4e.246d.9e00
ID=2 D0=2/1, D1=2/4, , will reload in 10 sec
Unmounting the External USB
We are in system resetSyncing file system
Rebooting...
:
:
:
:
Bootloader Version: 10.1.12T205 (Jun 06 2018 - 21:41:43)
SVR: 0x82100120, PVR: 0x80230032
!
ICX7750:26Q,Production-1
After boot up
[MEMBER]local-2@ICX7750-26Q Router>
Creating certificate, please wait...
SSL Client Certificate is successfully created
[MEMBER]local-2@ICX7750-26Q Router>
Power supply 1 detected.
Power supply 1 is up.
T=44.5: Election, was member, no change, ID=2, pri=0, 2U(2-3), No Active, nbr#=0 1, reason: u3: port-up, ,
T=1m21.2: Election, was member, no change, ID=2, pri=0, 3U(1-3), A=u1, nbr#=0 2, reason: u1: port-up, ,
T=1m23.5: Election, was member, no change, ID=2, pri=0, 3U(1-3), A=u1, nbr#=0 2, reason: u1: stk-po-chg, ,
T=1m28.7: Election, was member, no change, ID=2, pri=0, 3U(1-3), A=u1, nbr#=2 2, reason: u1: port-up, ,
Unit 2 becomes ready
Connecting to active controller 1 console...(Press Ctrl Shift - x to exit)
ICX7750-48F Router>UNIT2:T=2m32.2: Unit 2 is assigned standby by active u1.
T=2m36.7: Standby u2 start parsing running config from active controller u1
SZ swr host is set to swrqa.ruckuswireless.com
T=2m37.1: Standby u2 finished parsing running config from active controller u1.
UNIT2:Detect stack unit 3 has different ssl client key, will synchronize it
T:2m38.9: Done hot swap: standby controller u2 sets u3 to Ready.
UNIT2:Detect stack unit 1 has different ssl client key, will synchronize it
T:2m39.6: Done hot swap: standby controller u2 sets u1 to Ready.
!
!
!
ICX7750-48F Router>
Building a Stack
Stack construction methods
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
73
Содержание ICX 7650-48P
Страница 8: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 8 Part Number 53 1005572 01...
Страница 22: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 22 Part Number 53 1005572 01...
Страница 88: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 88 Part Number 53 1005572 01...
Страница 170: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 170 Part Number 53 1005572 01...
Страница 236: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 236 Part Number 53 1005572 01...