![Arris ICX 7650-48P Скачать руководство пользователя страница 156](http://html1.mh-extra.com/html/arris/icx-7650-48p/icx-7650-48p_configuration-manual_2976303156.webp)
3. Press Enter to accept the default ID, or type an alternative ID.
In the following example, the user elected to use the default ID.
1: icx7850-48fs-port d4c1.9e18.8dd9, type an ID (No: 0, default: 2):
You selected 1 unit(s): #1: ID=2,
Links U1--U2, #=8: 3/1--2/1, 3/2--2/2, 3/3--2/3, 3/4--2/4, 3/5--2/5, 3/6--2/6, 3/7--2/7, 3/8--2/8,
4. If the topology qualifies as a linear-topology trunk, you are given the option of selecting the linear-topology chain (enter
n) or a ring topology (enter y).
In the following example, a linear-topology trunk is selected.
There are total two units. The connections qualify a linear-topo that puts all discovered links to a
trunk.
Do you want a ring? (y: ring, n: linear-topo chain) (enter 'y' or 'n'): n
#1
+---+ +---+
| 1 |3/1==2/1| 2 |
+---+ +---+
5. When prompted to accept the topology, enter y (or type n to terminate the process).
Proceeding will produce the above topology. Do you accept it? (enter 'y' or 'n'): y
stack interactive-setup discovers 1 unit(s) and sends stack-port/trunk to chain 0: linear-topo: 2/1
to 2/8
stack-trunk 1/3/1 to 1/3/8 replaces stack-port 1/3/1 and stack-port 1/3/5
After you accept the topology, the second stack unit reloads, and stack formation is completed. You are prompted to
enter the write memory command.
Configuration changed. Please do "write memory".
ICX7850-32Q Router#T=11m12.7: Election, was alone --> active, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1
0, reason: u2: port-up, ,
Debug: Dec 13 22:12:21 Detect stack unit 2 has different ssh rsahost key, will synchronize it
Debug: Dec 13 22:12:21 T=11m13.2: Synchronize webauth files to u2
T:11m14.7: Done hot swap: active controller u1 sets u2 to Ready.
T=11m15.2: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 0, reason: u1: stk-
po-chg, ,
Stack unit 2 Power supply 1 is up
Stack unit 2 Power supply 2 is not present
Debug: Dec 13 22:12:28
Config changed due to add/del units. Do write mem if you want to keep it
Debug: Dec 13 22:12:31 T=11m23.2: Synchronize ssh rsa host key to u2
T=12m15.9: Assigned unit 2 to be standby
Debug: Dec 13 22:13:26 T=12m17.9: start running config sync to standby u2
Debug: Dec 13 22:13:26 T=12m18.6: Running config sync to standby u2 is complete
6. Enter the write memory command to save the configuration.
ICX7850-32Q Router# write memory
There is no startup config file, unable to save legacy config
Flash Memory Write (8192 bytes per dot)
Write startup-config done.
Automatic copy to member units: 2
Flash Memory Write (8192 bytes per dot)
.
Copy Done.
Stacking by Device
ICX 7850 stack configuration overview
Ruckus FastIron Stacking Configuration Guide, 08.0.90
156
Part Number: 53-1005572-01
Содержание ICX 7650-48P
Страница 8: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 8 Part Number 53 1005572 01...
Страница 22: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 22 Part Number 53 1005572 01...
Страница 88: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 88 Part Number 53 1005572 01...
Страница 170: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 170 Part Number 53 1005572 01...
Страница 236: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 236 Part Number 53 1005572 01...