background image

SkyLink
Base Station and Receiver

L5.0019058

U S E R   G U I D E

Содержание SkyLink

Страница 1: ...SkyLink Base Station and Receiver L5 0019058 U S E R G U I D E ...

Страница 2: ...n a data retrieval system or translated into any language in any form by any means without the prior written permission of ARRI If you are downloading files from our web pages for your personal use make sure to check for updated versions ARRI cannot take any liability whatso ever for downloaded files as technical data are subject to change without notice Art NetTM Designed by and Copyright Artisti...

Страница 3: ...3 Dimensions Dimensions 3 Dimensions Base Station Receiver ...

Страница 4: ...Content 4 Content Dimensions 3 Content 4 Safety Information 5 Introduction 6 Product Layout 7 Set Up 9 General Operation 10 Configuration 12 Troubleshooting 17 Specification 18 ...

Страница 5: ...sing Avoid direct illumination by other luminaires or other heat sources Check the mains cable and connector cable prior to every operation for damage In case of visible damage to the mains cable or the housing the device must not be operated any longer Damaged components must be replaced by an ARRI service center WARNING The SkyLink system is intended for professional use and may only be operated...

Страница 6: ...tworks An XLR port on the SkyLink Base Station provides DMX input output The DMX signal from the SkyLink Receiver can be daisy chained to multiple fixtures and communicate with both DMX and RDM Reliability Utilizing the popular CRMX protocol by LumenRadio SkyLink provides an encrypted error corrected signal linking fixtures with a robust connection even in the trickiest radio environments Properti...

Страница 7: ...fic DMX Indicates DMX traffic DHCP The SkyLink Base Station s DHCP service is assigning IP addresses to Ethernet and WiFi devices Feature Description Link Button Links or unlinks receivers Short press to link hold 3 s to unlink all Ethernet Standard RJ 45 Ethernet connector EtherCON compatible For use with Art Net and sACN communication 12 V DC Input Power Input 2 1mm x 5 5mm Barrel Center Positiv...

Страница 8: ... Signal Strength or greater ooo 60 Signal Strength or greater oo 40 Signal Strength or greater o 20 Signal Strength or greater Feature Description 5 Pin XLR Attaches to any standard 5 Pin DMX XLR port Swivels 180 to fit anywhere Unlink Button Hold to Unlink the receiver from the SkyLink Base Station Antenna 2dBi Antenna attached to RP SMA Connector USB A Tail Connects to a standard USB port for 5V...

Страница 9: ...power receptacle The SkyLink power supply is compatible with voltages ranging from 100V 240VAC Plug in SkyLink Receiver Simply plug the SkyLink Receiver into the DMX IN port on your ARRI SkyPanel or other DMX capable fix ture The XLR connector can swivel 180º to provide necessary clearance Plug the USB A tail into the USB port below the DMX IN on your SkyPanel to provide power Check if the USB mod...

Страница 10: ...umber of SkyLink Receivers Light Operation Now that your tablet or device is connected and your receivers are linked open your Art Net or sACN compatible DMX lighting control app In most cases use these default settings The SkyLink Base Station is capable of receiving a single DMX universe of 512 DMX channels Operating Range The SkyLink has a range of about 500 m 1 640 ft over CRMX External factor...

Страница 11: ...or more than 3 seconds to unlink all receivers currently paired with the SkyLink Base Station Factory Reset Follow these steps to restore the SkyLink Base Station to factory default settings Turn the Power switch of the SkyLink Base Station to the Off position While holding the RESET in with a pen turn the SkyLink Base Station Power switch On Hold the RESET button for at least 10 seconds The RESET...

Страница 12: ...mation States the model description of the device and the RDM UID Box Name Allows the user to set the name of the Base Station which will also be used as the WiFi SSID Factory Reset Allows the user to perform a factory reset which will restore all the device settings to their original facto ry defaults A factory reset can also be performed by holding the RESET button on the rear for 10 seconds whi...

Страница 13: ...tting IP Settings Page The IP Settings Page allows users to configure different settings in relation to IP Internet Protocol attributes DHCP Mode Click Save after a change is made to store your new setting Minimum Outputs 5mW suitable for small sized locations Low Outputs 25 mW suitable for medium sized locations Normal Outputs 100 mW suitable for large sized locations High FCC Mode Outputs 125 mW...

Страница 14: ...new setting Netmask A netmask is a method for dividing an IP address into subnets and specify the network s available hosts The netmask can be configured by the user The default netmask is 255 255 255 0 Click Save after a change is made to store your new setting Port Page The Port Page allows the user to configure which port the DMX RDM source is coming from and which protocol is used to transmit ...

Страница 15: ...ted WiFi access point can be used in conjunction with wired Ethernet for multi node systems 5 Pin XLR In ARRI SkyLink can optionally be controlled directly through the 5 pin XLR DMX port Choose DMX Source XLR on Port page This will allow for a control device such as a professional lighting console to be connected directly to the SkyLink Base Station Full RDM functionality is available via DMX In 5...

Страница 16: ...iFi and CRMX antennas should not be parallel but off angle from each other If WiFi signal problems such as lag or choppy DMX performance persist it may be necessary to adjust the position of the two antennas on the SkyLink Base Station Tilting the antennas perpendicular to each other or utilizing the optional Range Extender kit can enhance the distance of the WiFi signal If using other wireless tr...

Страница 17: ...can also be used to elevate antenna To less power of Base Station signal Increase Base Station CRMX output power Note requires restart may affect WiFi range WiFi performance is intermittent Control device not logged in Ensure the control device is logged into SkyLink Base Station s WiFi network Distance to control device too big Move the control device closer to the SkyLink Base Station Adjustment...

Страница 18: ...Device Input Voltage 12 V DC Weight 1 5 kg 3 3 lbs Housing Color Blue Silver Ambient Temperature Operation 20 to 50 C 4 to 122 F Protection Class IP Rating III IP20 Certifications CE FCC The antenna s used for this transmitter must be used to provide a separation distance of at least 20 cm from all per sons and must not be co located or operating in conjunction with any other antenna or transmitte...

Страница 19: ......

Страница 20: ......

Отзывы: