TECH. MANUAL
13
(7) Pump (E001) stuck.
Turn off the machine, and use screw driver to troll the pump’s fan.
If it still stuck, take off the pump’s cup and swirl the pump’s fan by tools.
4. Pump does not run or lack of pressure.
(1) Pump (E001) stuck.
Turn off the machine, and use screw driver to troll the pump’s fan.
If it still stuck, take off the pump’s cup and swirl the pump’s fan by tools.
(2) There were too much dust blocked the spindle filter (A002.1).
Using air compressor to blow out the dust from the filter (A002.1); replace a new
filter.
(3) Pump filter mesh (E010) blocked.
Clean filter or replace a new filter.
(4) Fitting (A023) much dust blocked
Clean the fitting.
5. Suction head does not move or move too slow
(1) PU Belt (A027.1) was loosed or broken.
Replace a new one..
(2) Pump (E001) stuck.
Turn off the machine, and use screw driver to troll the pump’s fan.
If it still stuck, take off the pump’s cup and swirl the pump’s fan by tools.
(3) Lack of power voltage.
Check your electric voltage was match to our machine.
Check power supply (B041).
6.
Membrane keyboard’s function key can’t work
(1) Membrane keyboard (B003) was damaged.
Replace a new membrane keyboard.
(2) Data cable TQU-28 (B006) was damaged.
Check or replacement a new cable.
(3) Main control board (D031) was damaged.
Check or replace the board.
Содержание AS 5500
Страница 1: ...TECH MANUAL AS 5500 BANKNOTE COUNTER TECH MANUAL 2022 09 Version...
Страница 18: ...TECH MANUAL 17 TECHNICAL DRAWING...
Страница 19: ...TECH MANUAL 18...
Страница 20: ...TECH MANUAL 19...
Страница 21: ...TECH MANUAL 20...
Страница 22: ...TECH MANUAL 21...
Страница 23: ...TECH MANUAL 22...
Страница 24: ...TECH MANUAL 23...
Страница 25: ...TECH MANUAL 24...
Страница 26: ...TECH MANUAL 25...
Страница 27: ...TECH MANUAL 26...