Sapporo TWIN
English
05060065 02 10/10/2007
17
These cabinets were tested for climatic class 3 (25°C; R.H. 60%):
The cabinets comply with the essential requisites of the following directives:
- Machine Directive
98/37 EEC
;
- Electromagnetic Compatibility Directive
89/336 EEC
and subsequent amendments
92/31 EEC,
93/68 EEC
;
- Low Voltage Directive
73/23 EEC
and subsequent amendment
93/68 EEC
.
The field of
EEC
directive
97/23 (PED)
does not apply according to the terms of Art. 1 paragraph 3.
5. Identification - Nameplate (Fig. 2)
The technical nameplate is situated on the back of the cabinet with all the technical characteristics:
1
Manufacturer's name and address
2
Name and length of the cabinet
3
Cabinet code number
4
Cabinet registration number
5
Power supply voltage
6
Power supply frequency
7
Max. absorbed current
8
Electric power absorbed at steady state during refrigerating phase (compr fans + hot
cables)
9
Electric power absorbed at steady state during defrosting phase (hot evaporator fan)
10 Illuminating power (where applicable)
11 Useful display surface
12 Type of refrigerating gas used in the appliance
13 Mass of refrigerating gas loaded in each appliance
14 Environmental climatic class and reference temperature
15 Class of protection against humidity
16 Manufacturing job number of the cabinet
17 Manufacturing order number of the cabinet
18 Manufacturing year of the cabinet
In case of technical service request, please communicate the following information for the
identification of the cabinet:
- product name
(Fig. 2 - 2);
- registration number(Fig. 2 - 4);
- job number
(Fig. 2 - 18).
6. Transportation (Fig. 4)
The cabinet is fitted with a wooden support fixed to the base for handling by means of fork-lifts.
Use a manual or electric lift truck suited for raising the cabinet in question.
7. Receipt and first cleaning
Upon receipt of the cabinet:
- Make sure that the packaging is intact and that it is not evidently damaged;
- Unpack the cabinet with care so as not to damage the cabinet itself;
- Check each single part of the cabinet making sure that all its components are intact;
- If anything is found to be damaged, immediately call the supplying company;
- Proceed with a first cleaning using neutral products, dry with a soft cloth, do not use abrasive sub-
stances or metal sponges, do not use alcohol or similar to clean parts in methacrylate (Plexiglas).
For correct packaging disposal, remember that it contains:
Climatic Class Temp. dry bulb
Relative
Humidity
Dew Point
1
16°C
80%
12°C
2
22°C
65%
15°C
3
25°C
60%
17°C
4
30°C
55%
20°C
5
40°C
40%
24°C
6
27°C
70%
21°C
Содержание SAPPORO TWIN MT