Santiago 2
English
05060185 00 19-06-2019
52
The cabinet
does not cool
sufficiently
• the cabinet is in defrosting
phase
• wait for defrosting to complete (about 30min)
• air inlets are obstructed
• release air inlets
• the load is not distributed even-
ly
• load the goods in an orderly fashion (Fig.15)
• the cabinet is next to air cur-
rents or heat sources
• check the position of the cabinet inside the
store chap.12
• the cabinet is not levelled
• level the cabinet see chap.12
The engine is
noisy
• screws and bolts are not tight-
ened
• tighten the bolts and screws
• the cabinet is not levelled
• level the cabinet chap.12
Condensate
• poor room conditions
• check the position of the cabinet inside the
store chap.12
• poor air ventilation
• check the operation of fans and wiring
• the window heaters do not work • check electrical connections
• check the operation of heating elements
• the windows are not closed
properly
• close the windows properly
Cabinet
temperature
is too high or
too low
• poor room conditions
• check the position of the cabinet inside the
store chap.12
• output air temperature is out-
side the specified range
• check the operation of evaporator fan
• check wiring and input voltage
• the fans are installed reversely; check and re-
store the air flow direction
• check that fan plenum is sufficient and not
obstructed
• check the intake pressure that should comply
with rated specifications
• the cabinet is defrosting.
• check defrosting parameters
• the capacitor or the evaporator
are freezing.
• check that the suction line is not obstructed
• the capacitor or the evaporator
are obstructed or dirty.
• proceed with cleaning
• the load is not distributed even-
ly
• load the goods in an orderly fashion (Fig.15)
Water leaks,
bad smell
• cabinet drains are obstructed or
damaged
• free the drain
• repair or replace the drains
• water collection tray is sealed
incorrectly
• seal it properly
• water collection tray overflows • check wiring of evaporation heater
• check the operation of evaporation heater
• insufficient joints between cabinets
in channel or joints not sealed cor-
rectly
• install and seal the joints
Frost or ice
in the cabinet
• the fans are not working in the
evaporator
• heating elements broken
• Sdef probe detached
• check electrical connections
• air currents that alter the circu-
lation of refrigerated air
• check the ventilation inside the store
i
in all cases not described or where it is not possible to solve the problem by following these
directions call the nearest authorised after-sales centre.