PLATFORM MOUNT MANUAL PARALLEL BARS INSTALLATION

 

AM-707, AM-710 

  

1.  Remove platform (49) from crate.  

DO NOT LIFT OR SUPPORT BY END RAMPS!!

 

 

2.  Set the platform on supports to get it off the floor far enough to allow access to the 

carriage bolts (45) during installation of the four upright supports. 

 

3.  Remove the retaining nuts and cap retainer washers from mounting bolts.  

(Non locking nuts used for shipping only) 

 

4.  Locate the four upright supports (42) and place on the platform (46) according to letter 

designations, with the height adjustment knobs facing outward as shown on page 8.

  

Hold 

carriage bolts in place from the bottom of platform, if necessary, to install upright supports, 

cap retainer washer (47), and lock nut (7).  NOTE: The square portion of the carriage bolts 

must be properly seated on the bottom of the platform to reach completely through the 

platform, support plate, washer and lock nut. 

 

5.  Tighten all lock nuts securely and install plastic bolt covers (48).   

CAUTION:  Do not over tighten or carriage bolts may pull too far through platform. 

 

6.  Place the handrails into position in the adjustment tubes and tighten the setscrews (38). 

 

FLOOR MOUNTED PARALLEL BARS INSTALLATION 

AM-711, AM-712 

 

NOTICE:

  

Armedica does not supply floor mounting hardware

.  A qualified professional 

should install the Floor Mounted Parallel Bars using hardware appropriate for the flooring material.  

Reference the floor layout drawing on page 9 to position the parallel bar support assemblies on 

the floor. 

 

MANUAL PARALLEL BARS OPERATING INSTRUCTIONS 

AM-707, AM-710, AM-711, AM-712 

 

ADJUSTING THE WIDTH AND HEIGHT OF THE PARALLEL BARS 

 

  Turn knobs to release adjusting tubes and set to the desired width. 

  Make sure adjusting tube knobs are securely tightened before use. 

 

PRECAUTIONS 

 

CAUTION:  When lowering or raising the parallel bars, keep hands and feet away from the moving parts. 

 

CAUTION:  Do not adjust the width or height of the parallel bars with the patients weight on the parallel 

bars. 

 

CAUTION:  Make certain the parallel bar height and width adjusting mechanisms are secure before use. 

 

The motor is double insulated for protection from EMI. This equipment has been tested and found to comply 

with the limits for medical devices to the IEC 60601-1-2: Third edition 2007-03. These limits are designed to 

provide reasonable protection against harmful interference in a typical medical installation. This equipment 

generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with 

the instructions, may cause harmful interference to other devices in the vicinity. However, there is no 

guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 

interference to other devices, which can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of the following measures:  

 

- Reorient or relocate the receiving device. 

- Increase the separation between the equipment. 

- Connect the equipment into an outlet on a circuit different from that to which the 

  other device(s) are connected. 

 

- Consult the manufacturer or field service technician for assistance. 

5

Содержание AM-700 Series

Страница 1: ...rs and operators of the ARMEDICA AM 700 Series Parallel Bars and contains installation instructions precautionary instructions and maintenance procedures for the following model numbers AM 700 AM 707...

Страница 2: ...move the cover plate from box 26 to allow access to inside of control stand 11 Using washers 44 and nuts 13 mount the control stand 11 to the platform 1 threading controller power cable and connector...

Страница 3: ...ID 8 7 02095 NUT NYLOCK JAM 1 2 13 8 8 02031 HEX HEAD SCREW 8MM 1 25X14Z 16 9 12633 COLUMN MOUNTING BRACKET 8 10 03183 CONTROL SWITCH 1 11 18672 CONTROL STAND 1 12 02131 PAN HEAD PHILLIPS SCREW 10x3 4...

Страница 4: ...knobs are securely tightened before use SYNCHRONIZATION AND CALIBRATION UNPLUG POWER CORD BEFORE DISCONNECTING ANY OTHER CABLES This unit has been initialized by Armedica Manufacturing Corp prior to...

Страница 5: ...s Type B Equipment An adequate degree of protection against electric shock is provided particularly regarding leakage currents No ground pin is necessary This unit is double insulated It is constructe...

Страница 6: ...AL PARALLEL BARS OPERATING INSTRUCTIONS AM 707 AM 710 AM 711 AM 712 ADJUSTING THE WIDTH AND HEIGHT OF THE PARALLEL BARS Turn knobs to release adjusting tubes and set to the desired width Make sure adj...

Страница 7: ...REW M6X40 16 32 02181 HEX HEAD CAP SCREW 5 16 18x2 1 2 16 33 02132 NUT U TYPE 10 025 150 9 16 CENTER 4 34 14607 STEP DECAL PLL SAFETY TRK 4x31 CUT 6 4 35 02105 NYLOCK NUT 5 16 18 16 36 02022 SHOULDER...

Страница 8: ...31 6 23 5 18 15 30 9 10 32 1 21 12 26 33 26 4 25 44 13 3 16 20 35 17 8 19 66 4 7 22 14 2 34 AM 700 AM 702 PARALLEL BARS 28 COVER PLATE 7...

Страница 9: ...40 43 36 36 39 29 24 15 15 15 9 60 23 23 42 22 41 37 38 38 38 AM 710 AM 707 MANUAL PARALLEL BARS FLOOR AND PLATFORM MOUNT 45 48 7 47 46 34 58 63 8...

Страница 10: ...9...

Страница 11: ...7 14604 BALANCE BEAM 2 1 2X5X80 1 ITEM NO PART NO QTY DESCRIPTION 61 04705 HITCH PIN CLIP 1 16x3 16 62 02044 CLEVIS PIN 1 4x1 1 4 53 14602 LADDER NOTCHED BOARD 1X4X84 6 6 3 ITEM NO PART NO QTY DESCRIP...

Страница 12: ...DICA selling dealer or approved ARMEDICA service agent 2 Any failure of the unit during the warranty period if the failure is not caused by a defect in material or workmanship or if the failure is cau...

Отзывы: