ELECTRIC PARALLEL BARS OPERATING INSTRUCTIONS
AM-700
SETTING THE PARALLEL BAR HEIGHT
•
Press the up arrow to raise the parallel bars.
•
Press the down arrow to lower the parallel bars.
•
The current height of the bars appears on the display.
SAVING THE MEMORY POSITIONS
This function makes it possible to save a particular height setting. Four different heights may
be saved. These saved positions can be used later.
•
Press (S) – an ‘S’ appears on the display. Press and hold one of the position buttons
(1, 2, 3 or 4). After pressing the position button, the number of the position button will
appear on the display next to the ‘S’.
•
After saving, a double click is heard and the current height re-appears on the display after
two seconds.
USING THE MEMORY POSITIONS
•
While holding down the desired memory position button, the bars will move toward the
predefined position and stop.
ADJUSTING THE WIDTH OF THE PARALLEL BARS
•
Turn knobs to release adjusting tubes and set to desired width.
•
Make sure adjusting tube knobs are securely tightened before use.
SYNCHRONIZATION AND CALIBRATION
UNPLUG POWER CORD BEFORE DISCONNECTING ANY OTHER CABLES
•
This unit has been initialized by Armedica Manufacturing Corp. prior to shipment and
should not need to be synchronized again unless a column or control box is replaced. If it
becomes necessary, follow these steps:
•
Bring the columns to the fully retracted position by holding the down button on the switch
until they stop retracting.
•
Release and press the down button again and hold for 30 seconds. The columns should
retract again slightly while the switch is held and then extend slightly.
•
The height display on the switch should read 26 in the lowest position. In the event that it
is incorrect, raise the columns to the uppermost position then lower them all the way
down.
Press the green “set” button. An “S” will appear in the display. Hold the “down” button for 5
to 10 seconds. The display will begin to flash. Release the “down” button and press it
again to make the display read 26. press the “set” button again to save the calibration.
In the event that the synchronization fails or for any other issues contact the service
department at Armedica Manufacturing.