Installation Manual Page |
13
Toll Free (US):
1-866-434-0807
Call (UK):
0121-608-7210
9.
Once connected, press enter and the enclosures system will be switched off and a
menu will be displayed on the terminal program in box 5, the current settings will be
displayed for all the components just above the menu shown in box 4 below.
Figure 4
10.
The settings for each component can then be changed by selecting the appropriate
option from the menu in box 5.
For example, to change the temperature at which the heater comes on enter ‘4’
followed by the return key. Then enter the new value followe
d by the letter ‘C’ (for
Centigrade) or ‘F’ (for (Fahrenheit) followed by the return key, such as 40C.
NOTE:
The menu will time out after 30 seconds if no commands are received and the
system will switch back on.