background image

Page | 9 

 

Commercial in confidence. Information for Use Manual Revision COU-E-REV12-080920 

4.  OPERATION 

Continued

 

 

4.6 Central Locking Castor System 

 

The central locking castor system is operated by use of foot pedals found at the foot end of 
the bed. 
 

WARNING

 

Operate the brake pedals with your feet while wearing suitable shoes. Do not 

operate the pedals with your hands. 

 

 

With the pedals in the 

Horizontal Free

 position 

the brakes are released, 
and the couch can be 
moved in any direction.

 

 

With the pedals in the 

Red - Down Brake 

position the brakes are 
applied to all four castors 
of the couch 
simultaneously and the 
couch is immobilised.

 

 

With the pedals in the 

Green - Down 
Steer/Track

 position, a 

single steering castor at 
the head end of the couch 
is engaged to provide 
better control when 
pushing the couch in a 
straight line.

 

 

CAUTION 

  Disconnect the bed power cable from the source before moving the couch. 

  Do not remove the power cable from the source by pulling on the cord. 

  Do not pull on the power cable or foot switch cable to manoeuvre the couch. 

 

Always disengage the castors to a “Fixed Mode” when couch is in a stationary 
position. 

 
 

 

 

 

 

 

 
 

Содержание Prioma Couch Electric

Страница 1: ...INSTRUCTIONS FOR USE COU E REV12 080920 Electric Prioma Couch Range...

Страница 2: ...t 8 4 3 Backrest Adjustment 8 4 4 Knee Positioning Adjustment 8 4 5 Battery Backup if fitted 8 4 6 Central Locking Castor System 9 4 7 Fold down Arms if fitted 10 4 8 Paper Roll Holder if fitted 11 5...

Страница 3: ...in the presence of flammable gases Do not use electrically operated couches in operating theatres Use the couch to support one patient only The Prioma couch is intended for one person use and may beco...

Страница 4: ...hospital lines and power cables are free from possible entanglement with mechanical parts of the couch Always ensure that attendant and patient limbs are free from potential entrapment areas before op...

Страница 5: ...tended Area of Use Prioma couches are appropriate for use in private practices nursing homes physio centres hospitals and clinics for the purpose of a wide range of examination and treatment procedure...

Страница 6: ...ks not shown in image D 125mm Central Locking Castors x 4 E ABS Plastic Crank Arm Covers F Handset Storage Bar both sides of couch G Central Lock Pedal Neutral Brake Tracking H Upholstered Foot Sectio...

Страница 7: ...e couch Disconnect the power supply cord from the electricity supply and store safely before moving the couch 3 1 Electricity Supply Connect the mains cable plug to a suitable socket outlet Make sure...

Страница 8: ...tween the outer extremities of the couch and other building fixtures and equipment when operating couch functions Adjustment of the couch occurs only while the button is pressed Adjustment will stop w...

Страница 9: ...t use Bed operation will be slower when the power cord is unplugged and couch is powered by the batteries CAUTION If battery backup is fitted and to ensure that the battery is kept fully charged and p...

Страница 10: ...d in any direction With the pedals in the Red Down Brake position the brakes are applied to all four castors of the couch simultaneously and the couch is immobilised With the pedals in the Green Down...

Страница 11: ...rioma 1 Section Arm Length 1000mm O A Fig 4 To Lower Grip and hold the Arm in the middle of the top rail A and pull up as indicated by the directional arrow fig 1 to unlock Controlling the Arm allow i...

Страница 12: ...processes on the Prioma Couch The following procedure also applies to the accessories 5 1 Cleaning Clean all surfaces with a disposable cloth soaked in a neutral detergent and hand hot water Start by...

Страница 13: ...the power supply plug is not damaged If either the power cable or plug is damaged then both the cable and plug must be replaced as a complete assembly by an approved service agent CASTORS 1 Apply the...

Страница 14: ...s should take no more than one 1 minute to complete Visual Inspection of Control Panel Handset Casing 1 1 Inspect the outer plastic casing for any obvious cracks or damage 1 2 Inspect for damage to th...

Страница 15: ...otswitch plugs disconnected Check the plugs are fully inserted in the control box Blown fuse Contact your local Arjo Service Department Damaged footswitch cable Replace footswitch Control box overheat...

Страница 16: ...0 Kg 8 0 Kg With Fold down Arms Paper Roll Holder fitted excluding paper roll 13 5 Kg 9 5 Kg 9 5 Kg Safe Working Load SWL 200 Kg 200 Kg 200 Kg Maximum Patient Weight 165 Kg 165 Kg 165 Kg Electrical D...

Страница 17: ...ation Label Safe Working Load Refer to Instructions for Use Date of Manufacture Product Reference Number 11 Digit Code Representing Various Options Build Types Product Serial Number Manufacturer Indic...

Страница 18: ...ularly gas springs actuators batteries and other electrical devices may produce substances that are hazardous to the environment To minimise these hazards contact Arjo for information on correct dispo...

Страница 19: ...regarding this product please contact your local Arjo office or approved distributor Arjo offices can be found at www arjo com int region select Have the model number and serial number of the equipme...

Страница 20: ...ensure ergonomic patient handling personal hygiene disinfection diagnostics and the effective prevention of pressure ulcers and venous thromboembolism we help professionals across care environments to...

Отзывы: