background image

Page | 2 

 

Commercial in confidence. Information for Use Manual Revision COU-E-REV12-080920 

1.  WARNINGS & CAUTIONS 

 
 
 
 
 
 
 
 
 
 
 

Important

 that this manual is read in its entirety prior to the operation of the couch. The 

manual is designed to ensure that users are equipped with the information required to 
competently and responsibly operate the couch and its accessories. 

 

It is recommended that the instructions for use be kept in an easily accessible place for 
quick reference. If required, Arjo product specialists can provide additional training. 

 

All warnings and cautions within this manual should be strictly adhered to. Failure to do so 
could result in harm to the patient, or operator. 

 

Warnings

 highlighted throughout this manual identify possible hazards in procedures or 

conditions, which if not followed correctly could result in serious injury or fatality. 
  

Cautions

 highlighted throughout this manual identify possible hazards in procedures or 

conditions, which if not followed correctly could result in equipment damage or failure. 

 

 GENERAL WARNINGS 

  Electrical equipment can be hazardous if used incorrectly. 

  Do not use electrically operated couches in the presence of flammable gases. 

  Do not use electrically operated couches in operating theatres. 

  Use the couch to support one patient only. The Prioma couch is intended for 

one person use and may become unstable if used incorrectly. 

  It is recommended that the couch be positioned at its lowest height when 

unattended by caregivers to minimise the risk of patient injury from falls when 
getting on and off the couch. 

  Residual current devices (RCD) are not supplied with the Prioma couch. 

Please consult with your Biomedical Engineer/advisor concerning RCD 
requirements. 

  The full safe working load (SWL) of the Prioma couch is 200Kg. This includes 

the mass of the patient, and any accessories fitted to the couch. 

  Do not place the power cord across the upholstered surface of the couch. 

When the couch is not connected to mains power, always store the mains 
power cord safely. 

  Do not use accessories that are not designed or approved for use with the 

Prioma couch.

 

 

 

WARNING  

Indicates possible hazard in procedures or conditions which, if not correctly 
followed, could result in death, injury or other serious adverse reactions. 

 

CAUTION  

Indicates possible hazard in procedures or conditions which, if not correctly 
followed, could result in equipment damage or failure. 

 

Explains or amplifies a procedure or condition 

 

Indicates an optional item or feature 

 

Содержание Prioma Couch Electric

Страница 1: ...INSTRUCTIONS FOR USE COU E REV12 080920 Electric Prioma Couch Range...

Страница 2: ...t 8 4 3 Backrest Adjustment 8 4 4 Knee Positioning Adjustment 8 4 5 Battery Backup if fitted 8 4 6 Central Locking Castor System 9 4 7 Fold down Arms if fitted 10 4 8 Paper Roll Holder if fitted 11 5...

Страница 3: ...in the presence of flammable gases Do not use electrically operated couches in operating theatres Use the couch to support one patient only The Prioma couch is intended for one person use and may beco...

Страница 4: ...hospital lines and power cables are free from possible entanglement with mechanical parts of the couch Always ensure that attendant and patient limbs are free from potential entrapment areas before op...

Страница 5: ...tended Area of Use Prioma couches are appropriate for use in private practices nursing homes physio centres hospitals and clinics for the purpose of a wide range of examination and treatment procedure...

Страница 6: ...ks not shown in image D 125mm Central Locking Castors x 4 E ABS Plastic Crank Arm Covers F Handset Storage Bar both sides of couch G Central Lock Pedal Neutral Brake Tracking H Upholstered Foot Sectio...

Страница 7: ...e couch Disconnect the power supply cord from the electricity supply and store safely before moving the couch 3 1 Electricity Supply Connect the mains cable plug to a suitable socket outlet Make sure...

Страница 8: ...tween the outer extremities of the couch and other building fixtures and equipment when operating couch functions Adjustment of the couch occurs only while the button is pressed Adjustment will stop w...

Страница 9: ...t use Bed operation will be slower when the power cord is unplugged and couch is powered by the batteries CAUTION If battery backup is fitted and to ensure that the battery is kept fully charged and p...

Страница 10: ...d in any direction With the pedals in the Red Down Brake position the brakes are applied to all four castors of the couch simultaneously and the couch is immobilised With the pedals in the Green Down...

Страница 11: ...rioma 1 Section Arm Length 1000mm O A Fig 4 To Lower Grip and hold the Arm in the middle of the top rail A and pull up as indicated by the directional arrow fig 1 to unlock Controlling the Arm allow i...

Страница 12: ...processes on the Prioma Couch The following procedure also applies to the accessories 5 1 Cleaning Clean all surfaces with a disposable cloth soaked in a neutral detergent and hand hot water Start by...

Страница 13: ...the power supply plug is not damaged If either the power cable or plug is damaged then both the cable and plug must be replaced as a complete assembly by an approved service agent CASTORS 1 Apply the...

Страница 14: ...s should take no more than one 1 minute to complete Visual Inspection of Control Panel Handset Casing 1 1 Inspect the outer plastic casing for any obvious cracks or damage 1 2 Inspect for damage to th...

Страница 15: ...otswitch plugs disconnected Check the plugs are fully inserted in the control box Blown fuse Contact your local Arjo Service Department Damaged footswitch cable Replace footswitch Control box overheat...

Страница 16: ...0 Kg 8 0 Kg With Fold down Arms Paper Roll Holder fitted excluding paper roll 13 5 Kg 9 5 Kg 9 5 Kg Safe Working Load SWL 200 Kg 200 Kg 200 Kg Maximum Patient Weight 165 Kg 165 Kg 165 Kg Electrical D...

Страница 17: ...ation Label Safe Working Load Refer to Instructions for Use Date of Manufacture Product Reference Number 11 Digit Code Representing Various Options Build Types Product Serial Number Manufacturer Indic...

Страница 18: ...ularly gas springs actuators batteries and other electrical devices may produce substances that are hazardous to the environment To minimise these hazards contact Arjo for information on correct dispo...

Страница 19: ...regarding this product please contact your local Arjo office or approved distributor Arjo offices can be found at www arjo com int region select Have the model number and serial number of the equipme...

Страница 20: ...ensure ergonomic patient handling personal hygiene disinfection diagnostics and the effective prevention of pressure ulcers and venous thromboembolism we help professionals across care environments to...

Отзывы: