001-05415-EN rev

. 4

General Information

3

Symbols Used

General Symbols

Symbols

Key to Symbols

Name and address of the 

manufacturer

Manufacturing date.

REF

Manufacturer’s catalogue number.

CE marking indicating conformity 

with European Community 

harmonised legislation.

 

Read the Instructions for use before 

use.

SWL

Safe Working Load is the 

maximum load the device 

is rated for safe usage.

Correct way to proceed.

Wrong way to proceed.

Universal Dual Loop label

Strap Maintenance Related Symbols

Symbols

Key to Symbols

80°C

Washing temperature 80°C 

(176°F) permanent cycle.

Do not bleach.

Do not dry clean.

Do not iron.

Do not tumble dry.

General Information

General Information

Содержание Dual-Loop Attachment Straps

Страница 1: ...001 05415 EN rev 4 10 2020 INSTRUCTIONS FOR USE Dual Loop Attachment Straps...

Страница 2: ...ing to the Arjo group of companies Arjo 2020 As our policy is one of continuous improvement we reserve the right to modify designs without prior notice The content of this publication may not be copie...

Страница 3: ...4 Safe Working Load 4 Safety Directions 4 Parts Designation 5 DUAL LOOP ATTACHMENT STRAPS Compatibility 5 Using the DUAL LOOP ATTACHMENT STRAPS 6 Using the Ferno Scoop EXL Stretcher with the Maxi Move...

Страница 4: ...coop EXL Stretcher is intended to be exclusively operated by a trained caregiver as per the product Users Manual for transferring patients who have been assessed as requiring lifting in a supine posit...

Страница 5: ...ormity with European Community harmonised legislation Read the Instructions for use before use SWL Safe Working Load is the maximum load the device is rated for safe usage Correct way to proceed Wrong...

Страница 6: ...lifting capacity of 227 kg 500 lb WARNING The DUAL LOOP ATTACHMENT STRAPS are intended to be used for patients whose weight is within a specified safe working load Do not attempt to lift more than the...

Страница 7: ...come unstable which could lead to patients falling causing injuries Only use with a Maxi Move floor lift for transferring only Head section Dual Loop Attachment Straps Dual Loop Attachment Straps Foot...

Страница 8: ...p EXL Stretcher proceed to attach them according to the precise locations and in the correct way as shown in Fig 3 Fig 3 4 Bring the stretcher frame over to the patient and align the stretcher frame s...

Страница 9: ...7 Proceed with the transfer NOTE When transferring the patient through a door rotate the stretcher frame until the patient s head is close to the mast see Fig 7 In this position the complete unit may...

Страница 10: ...rage conditions Straps should be store away from direct sunlight stress pressure excessive heat or humidity The straps should be kept away from contact with sharp objects corrosives or other possible...

Страница 11: ...lyester webbing ENVIRONMENTAL CONDITIONS Ambient temperature range Operation and Storage 40 C to 70 C 40 F to 158 F Relative humidity range Operation and Storage 10 to 100 Atmospheric pressure range O...

Страница 12: ...001 05415 EN rev 4 Specifications 10 Labels Fig 13...

Страница 13: ...Intentionally left blank...

Страница 14: ...Intentionally left blank...

Страница 15: ...08 9th Floor HQ Building North Tower Dubai Science Park Al Barsha South P O Box 11488 Dubai United Arab Emirates Direct 971 487 48053 Fax 971 487 48072 Email Info ME arjo com NEDERLAND Arjo Nederland...

Страница 16: ...ergonomic patient handling personal hygiene disinfection diagnostics and the effective prevention of pressure ulcers and venous thromboembolism we help professionals across care environments to conti...

Отзывы: