HYDROSENSE HS2410
Revision 5.0
P a g e 6 | 27
Specification
Details
Mechanical Specification:
Enclosure Dimensions
12.0"W x 37.5"H x 9.25"D (305mm W x 953mm H x 235mm D)
Sample Inlet
3/8” NPT female
Sample Outlet
2” NPT male (outfall must be unrestricted gravity to drain)
Weight
33Kg (73 lbs)
Enclosure Rating
Type 4X, IP65, 316 Stainless Steel with viewing window
Approval Standards:
CAN/CSA-C22.2 No. 0-M91
CAN/CSA-C22.2 No. 94-M91
C22.2 No. 142-M1987
C22.2 No. 213-M1987 (Hazardous Location : Class I, Division 2, Groups
A, B, C and D)
UL 50 (11th Ed.) 1995
UL 916 (Third Ed) March 2006
UL 1604 (Third Ed) Feb 2004 ( Use in Class I and II, Division 2; Class III
Hazardous (Classified) Locations)
CE
ABS Design Assessment
IMO MEPC.107(49) (conditional to site monitoring requirements) **
(USCG certified)
* UL certified at 120
10% VAC and 230
10% VAC
** The HydroSense 2410 has been third party tested and certified that it is
in compliance with the IMO MEPC.107 (49) guidelines. The MEPC 107(49)
guidelines require that the site must log and retain data for 18 months. A
sample stream by-pass alarm must also be installed and logged. To meet
the IMO MEPC. 107(49), the site must consider these requirements. A kit
is available from Arjay Engineering if these conditions are not met at site.
1.0 USE
HAZARD
INFORMATION
CAUTION
Indicates a potentially hazardous situation that may result in minor or
moderate injury.
WARNING
Indicates a potentially or imminently hazardous situation which, if not
avoided, could result in death or serious injury.
DANGER
Indicates a potentially or imminently hazardous situation which, if not
avoided, will result in death or serious injury.
NOTICE
Indicates a situation which, if not avoided, may cause damage to the
instrument. Information that requires special emphasis.