MENU STRUCTURE

 

Accessories menu

 

Heat regulation

The standard equipment of the Ariterm B pellet boiler includes a heat regulator that 

can be used to control at most two heating circuits. A temperature graph for supply water tem-

perature adjustments can be created for each circuit. Heating circuit 1 can be fine-adjusted by 

means of the indoor temperature sensor. In addition, the automatic equipment contains a cir-

culation pump control outlet that depends on outdoor temperature. Standard delivery includes 

the control kit for heating circuit 1, the shunt motor/valve and the temperature sensors (supply 

water, outdoor and indoor temperature).

 

Electrical installations

The terminal blocks for shunt motors and temperature sensors are under the front panel. The 

same applies to the circulation pump control. The connection must be carried out according to 

the connection diagram. NOTE! It is recommended to keep the wires of the temperature sen-

sors separate from the feeding cables. Use the lead-ins on the right-hand side of the boiler roof 

for the temperature sensors.  The wires of the temperature sensors should be kept as short as 

possible. NOTE! If the outdoor temperature sensor is detached or broken, the outdoor tem-

perature is 0 ºC by default. 

In connection with floor heating, it is important to determine the supply water min and max 

values for the temperature graph. With parquet floor, the supply water temperature should not 

rise above 45ºC. In these cases, it is recommended to install a thermostat for the circulation 

pump control. The thermostat switches the pump control off if the supply water temperature 

rises above 45ºC. If the supply water temperature is too high, this may damage parquet floor.

 

General information

The temperature graph determines the supply water temperature according to the outdoor 

temperature. The colder it is outside, the warmer the supply water. However, in connection 

with radiator heating, the supply water temperature increases exponentially when the outdoor 

temperature decreases. With a correct temperature graph, the room temperature is pleasant re-

gardless of the temperature outside. 

Stone floors may feel cold in summer. In this case, the supply water temperature can be set to 

at least 22-25 ºC to keep the floor pleasantly warm. In this situation, take into account the Cir-

culation Pump Stop setting. Heating circuit 1 may also be equipped with an indoor tempera-

ture sensor. The indoor temperature can be set to a certain value. The temperature graph can 

be fine-adjusted in order to reach this value. The room coefficient can be used to determine the 

supply water correction coefficient in order for the indoor temperature to reach the set value. 

The factory setting is 2 ºC. In other words, if the indoor temperature is 19 (20)ºC, the supply 

water temperature increases by 2 ºC in order for the set indoor temperature to be achieved. 

The room coefficient depends on insulation level and heating system.

 

Residual oxygen (accessory)

The value of the residual oxygen measurement can be seen in the main menu and in the 

graphic. The measurement is not available in Maintain mode. This saves energy and the sen-

sor. Adjust first the power of the fan so that the oxygen value is between 7% and 8%. The cycle 

in Power mode should be as long as possible in order for the combustion session to normalise. 

Then, set the Residual Oxygen setting to On mode from the Accessories menu.  After this, if 

the residual oxygen level becomes too low, the burner will automatically increase the fan power 

in order for combustion to remain good. The residual oxygen measurement gives an alarm 

when the value becomes too low. The power source for the oxygen sensor must always be con-

nected if the burner is in use, otherwise the sensor can become dirty and function will be im-

paired.

 

Tachometer

The tachometer measures/checks the blower rotation speed, which can also be seen in a graph-

ic on the screen. If the fan is blocked or broken, the tachometer detects the fault and stops the 

burner. 

 

Flue gas fan

The boiler is equipped with a flue gas fan. The fan power can be set to Power mode or Main-

tain mode. The setting can be made in the Accessories menu (Smokegasfan Max and Min). 

The flue gas fan power must be controlled so that there is a vacuum of 8-15 Pa in the fire box. 

Metering can be carried out via the hole blocked by a screw under the flame sensor.

 

Automatic convection cleaning system

The automatic convection cleaning system reduces the amount of cleaning needed by the boiler 

and maintains the burner’s high efficiency. (NOTE! See page 20).  The operating time and 

pause time for cleaning are determined as needed.

Menu

Setting

Description

Residual oxygen

On/Off

Fan power adjustment according to residual oxygen. The oxygen va-

lue can be seen in the main menu and in the graphic.

Heating circuit

On/Off

Heat regulation of two heating circuits possible. Menu Shunt control 

2 is visible, when the sensor is connected.

Tachometer

On/Off

Not in use

Load pump 

• 

Start

• 

Stop

• 

Load pump diff

On/Off
0 - 95 °C
0 - 95 °C
0 - 50 °C

Load pump function (tank sensor)
Tank temperature, when burner start ignition
Tank temperature, when burner stops
Load pump goes on, when boiler temp > set temp - Load pump diff

Conv. cleaning

  Time On
  Time Off

On/Off
3 min (0-10 min)
4 h (0-250 h)

Commissioning of the automatic convection cleaning system and de-

termination of operating times. See page 20.

Smokegasfan Max

30 % (0-100 %)

Flue gas fan power in Power mode.

Smokegasfan Min

0 % (0-30 %)

Flue gas fan power in Maintain mode.

Содержание Biomatic+ 20

Страница 1: ... Ariterm Biomatic 20 ARITERM VTT S 07229 11 1 INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...oden frame The base is a platform from which the boiler can be safely lifted The package should be unwrapped as close to the installation site as possible The factory has insured the boiler against damage during transport from the factory to the first intermediate storage site It is important for the person who receives the boiler to verify the state of the boiler before its acceptance In case of ...

Страница 3: ...m Electrical values burner side Power supply Supply cable Fuse size Power in operation Power in connection 400 V 3 phase 50 Hz 9 kW resistance MMJ 5x2 5s 9 kW resistance 3x16 A Burner ignition 500 W Burner normal 40 W 9 kW resistance about 10 kW depending on equipment TECHNICAL DATA ARITERM BIOMATIC Standard delivery Four way mixing valve ESBE TM 20 Sweeping gear Dirt trap Brick support Flue duct ...

Страница 4: ...ed from the ash box located in the lower part of the boiler Ash can also be removed into a special ash pan by means of an ash trap or a common vacuum cleaner However the ash may still be hot Therefore the ash trap must be heat resistant Standard equipment includes an automatic heat regulation system that adjusts the sup ply water temperature according to the tem perature outside For safety reasons...

Страница 5: ...tance BURNER OPERATING PRINCIPLE Green The burner is on Red Alarm the burner is off Blinking light Warning light do not turn the burner off Arrow keys browsing menus changing setting C button exiting menus acknowledging warnings ac knowledgement of setting Enter button selecting settings go to sub menu 1 Inner circulation pump switch 2 Inner circulation pump fuse 3 Display 4 Over heating sensor 5 ...

Страница 6: ...nal circulation pump through the venting screw located in the pump head the flue damper if any is open the circulation damper located in the convection part of the boiler is in place the circulation pump is running the network valves are open the ventilation air intake is open the safety valve is in working order and there are no obstacles between it and the boiler BOILER INSTALLATIONS Flue pipe c...

Страница 7: ...4 WAY VALVE FLOOR HEATING RADIATOR HEATING 3 CONNECTION SET OF THE ADDITIONAL HEATING CIRCUIT RADIATOR HEATING 4 HEAT PIPE PUMP FLOOR HEATING 5 HEAT PIPE PUMP RADIATOR HEATING 6 FLOOR HEATING NETWORK MANIFOLDS 7 RADIATOR HEATING NETWORK 8 EXPANSION VESSEL 9 SERVICE SHUT OFF VALVE 10 SAFETY VALVE 11 FILLING VALVE 12 FEED MIXING VALVE 13 DOMESTIC WATER CIRCULATION PUMP PIPE INSTALLATIONS VW CW DW ...

Страница 8: ...ARITERM SWEDEN AB ARITERM OY Asennus ja käyttöohje Installation och driftanvisning Installation and operating instruction UK 25 05 2012 8 32 ARITERM VTT S 07229 11 1 WIRING DIAGRAM ...

Страница 9: ...urner head The success of the cold start can be ensured by sufficiently increasing the set boiler water temperature and by changing it back to the desired value after ignition Hot start The burner performs a hot start when the boiler water temperature is within 8 C of the set temperature for example after a short power failure During a hot start the burner uses the embers in the burner head for ig...

Страница 10: ...rner and control the external storage auger When the pellet surface drops below the level switches the external auger activates factory setting 30 s The operating time of the external auger should be long enough for the pellet surface to rise to the level of the burner up per connection Time can be adjusted from Auger External in the Power menu If the time is too long the pellets rise to the drop ...

Страница 11: ...High auger Low auger High fan Low fan Min auger Power settings Cleaning fan Min fan Holding time Coldstart amount Warmstart amount Coldstart settings Auger external Manual Start backup El El step Level monitor Test outputs Optical monitor English Default settings Adjustment Diff temperature Accessories Flow water min Heating Curve Flow water max Curve comp 0 Curve comp 5 Curve comp 5 Circ pump sto...

Страница 12: ...enu Adjust 0 20 C Fine adjustment of heating circuit 1 visible if activated from the Accessories menu and if the internal sensor is not connected Menues Accessing submenus Burner Adjustments Ope rating Time Pellet Store Power Heat Regulati on Service Main menu Menu Setting Description El step 0 3 Activation of electrical resistances 0 not in use 1 3 kW 2 6 kW 3 9 kW Start backup El 10 40 C Activat...

Страница 13: ...wer mode the blower goes to 100 power and keeps the air vents clean Holding time 60 min No 0 120 min Time between ember maintenance cycles The auger burner carries out a 1 minute feeding cycle while the burner is in Maintain mode No The burner does not maintain the embers In this case the burner always performs a cold start when starting up To be used for example with an accumulator Auger external...

Страница 14: ...efficient can be used to determine the supply water correction coefficient in order for the indoor temperature to reach the set value The factory setting is 2 ºC In other words if the indoor temperature is 19 20 ºC the supply water temperature increases by 2 ºC in order for the set indoor temperature to be achieved The room coefficient depends on insulation level and heating system Residual oxygen...

Страница 15: ... heating circuits Heat circuit menu The graph curves more quickly when the outdoor temperature is above 16 ºC The Flow Water Max and Min settings can be used to cut the top and bottom of the graph The angular coefficient of the graph slightly increases when the Curve setting is increased Temperature graph compensation The graph can be compensated when the outdoor temperature is 5 ºC 0 ºC and 5 ºC ...

Страница 16: ...indicative and fine adjustment might be required Floor heating system A thermostat is installed in the circulation pump control of the heating circuit The thermostat switches the pump control off if the supply water temperature rises above 45 ºC If the supply water temperature is too high this may damage parquet floor Control If when the outdoor temperature is below 0 ºC the room temperature is to...

Страница 17: ... connection Control module Power source 230 VAC 12 VDC Heated oxygen sensor The Pellet boiler Ariterm Biomatic can be equipped with a heated oxygen sensor that facilitates control of the burner and which if necessary can regulate the combustion air fan output if the combustion is poor Residual value is displayed on the display The heated oxygen sensor can be easily connected to the boiler at a lat...

Страница 18: ... cleanliness of the fla me detection sensor 2 Ember maintenance time Power menu 1 Check the flame detection system as specified above 2 Check the embers while being in Maintain mode Excessive draught may burn the embers completely In this case reduce the draught and the time of the Ember Maintenance setting If the alarm has been given af ter cleaning the burner head increase the set temperature of...

Страница 19: ...switches must be cleaned all the time they may be defective and the instal ler should have a look at them A possible foreign object in the pellet fuel must be removed if it gets stuck in the blocking feeder or in one of the feeding augers Remove the upper connection and take out the possible fo reign object from the feeding auger or blocking feeder ALARMS AND TROUBLESHOOTING Alarm message Cause Ch...

Страница 20: ...PS 25 40 pump 1544 Boiler temperature sensor 5358 Flue gas temperature sensor 5022 BeQuem 20 inner cage 1692 Display card BM BQ 5820 ESBE ARA661 shunt motor 5062 Sweeping motor SPG TS09 0175 1691 Controller card Biomatic 5291 Outdoor temperature sensor 5292 Indoor temperature sensor 5718 Supply water sensor 5346 Chain wheel Z 12 5023 Hub chain wheel Z 15 5831 Hub chain wheel Z 24 5885 47 link chai...

Страница 21: ...ed with the boiler see the next page Finally empty the ash box The ash from the ash box can be used to deter mine whether combustion has been good The ash should be powdery The interval for ash removal and boiler cleaning can be specified in the Service menu on the basis of experience The boiler should be cleaned when the temperature of flue gases rises by 20ºC with respect to the temperature they...

Страница 22: ...n power before maintenance work Other boiler cleaning operations Ash box emptying Flue duct cleaning Convection channel cleaning 2 times a year Combustion chamber cleaning as needed Convector cleanout hatch Clean the flame detector of impurities NOTE If the protective glass of the flame detector breaks or detaches the flame detector can no longer be used and must be replaced with a new one Remove ...

Страница 23: ... convection channel 3 Lift the rocker switch to the side 6 Lift off the holder and the springs from the convec tion 7 Sweep the convection pipe surface with a brush remove any ash Push the brush up and down again 8 Reinstall all the springs and lifting levers illustrated 9 Install the convection channel hatch and the rocker switch 5 Lift off the second hatch of the convection channel 10 Install th...

Страница 24: ...rities sand These materials cannot be detected before burning NOTE If the ash is sin tered all sintered material must be continuously removed from the burner head Fuel storage Thanks to the feeding system it is possible to build the pellet store for so called bulk deliveries The store can be placed either inside or in a separate building outside the house The shorter the transport distance from th...

Страница 25: ... silo is 300 litres and its filling is facilitated by the intermediate grid in the silo Contrary to the figure the silo is delivered with a lid NOTE More information on the installation of PS300 Feedo can be found in separate manuals Depo Feed chute Depo is a patented pellet transfer system that effectively reliably and quietly feeds pellets from the silo via the feeding system to the burner Feedo...

Страница 26: ...fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that...

Страница 27: ...Flue gas temperature Max CO O2 CO2 Combustion efficiency Draught mm Blower Auger Flue gas temperature Mean CO O2 CO2 Combustion efficiency Draught mm Blower Auger Flue gas temperature Min CO O2 CO2 Combustion efficiency Draught mm Blower Auger Dealer Installer Installer Date After installation the burner must be adjusted using a flue gas analyser INSTALLATION REPORT ...

Страница 28: ...ARITERM SWEDEN AB ARITERM OY Asennus ja käyttöohje Installation och driftanvisning Installation and operating instruction UK 25 05 2012 28 32 ARITERM VTT S 07229 11 1 NOTES ...

Страница 29: ...NOTES ...

Страница 30: ...ARITERM SWEDEN AB ARITERM OY Asennus ja käyttöohje Installation och driftanvisning Installation and operating instruction UK 25 05 2012 30 32 ARITERM VTT S 07229 11 1 NOTES ...

Страница 31: ...ARITERM SWEDEN AB ARITERM OY Asennus ja käyttöohje Installation och driftanvisning Installation and operating instruction UK 25 05 2012 31 32 ARITERM VTT S 07229 11 1 NOTES ...

Страница 32: ...ORGANISATION CERTIFIED BY ARITERM VTT S 07229 11 1 ARITERM SWEDEN AB Flottiljvägen 15 39241 Kalmar www ariterm se 0771 442850 ...

Отзывы: