MOUNTING INSTRUCTIONS (Fig.1)
1.

Lift off the cover plate 

À

À

À

À

À

 as shown.

2.

Open the detector 

Á

Á

Á

Á

Á

 and remove electronic module 

Â

Â

Â

Â

Â

, taking care not to

touch pyro-electric sensor 

Ã

Ã

Ã

Ã

Ã

.

3.

Break out one or both cable entry hole(s) 

Ä

Ä

Ä

Ä

Ä

 as required.

4.

Mount the detector between 1.8 to 3.0 m high.

5.

Select mounting holes for corner 

Å

Å

Å

Å

Å

 or flat wall 

Æ

Æ

Æ

Æ

Æ

 mounting.

6.

Use the base as a template for marking screw hole locations on the wall.

7.

Fasten the base to the wall.

8.

Strip cable for 5 cm and pull it through the cable entry hole(s) 

Ä

Ä

Ä

Ä

Ä

 and strain

relief 

È

È

È

È

È

.

9.

Replace the electronic module 

Â

Â

Â

Â

Â

 and wire detector as shown (Fig. 4-5).

10. Replace cover 

Á

Á

Á

Á

Á

, insert screw 

Ç

Ç

Ç

Ç

Ç

 and replace cover plate 

À

À

À

À

À

.

The DD490 series detector is a microwave verified PIR and should be installed
to maximize PIR detection. The best detection is therefore obtained with the
expected movement of an intruder perpendicular and/or diagonal to the
mounting location.

SITING THE DETECTOR
The dual technology processing of this detector resistants false alarm hazards.
Nevertheless avoid potential causes of instability such as:

PIR risks:
-

Direct sunlight on the detector.

-

Heat sources within a field of view.

-

Strong draughts onto the detector.

-

Large animals in a field of view.

Microwave risks:
-

Mounting on a surface susceptible to vibrations.

-

Metal surfaces that reflect microwave energy.

-

Water movement through plastic pipes.

-

Heating or air-conditioning fans pointed directly at the detector.

WALK TEST LED FUNCTIONS
To walk test the DD495/DD496  make sure jumper J3 is in the ON position or
the LED is enabled remotely.
In the DD497/DD498 the LED must be enabled by applying a "CV" signal to
terminal 10.

Select the required function of the LED at jumper J1.
DUAL

= Detector Alarm.

The LED lights when the detector is in
alarm.
Relay follows LED.

MICROWAVE =  Microwave  Alarm. The LED lights when the microwave chan-

nel is in alarm.
Relay is always in alarm.

PIR

= PIR alarm.

The LED lights when the signal in the PIR
channel exceeds the alarm level.
Relay is always in alarm.

Use "MICROWAVE " and "PIR" when required to locate the coverage patterns
of the individual technologies.

RANGE ADJUSTMENT
Programme the range at jumper J4.
20 m = maximum range up to 20 m.
12 m = medium

range up to 12 m.

  7 m = minimum range up to   7 m.

Always select the lowest range setting possible for the dimensions of the
protected area.
1) Select PIR channel on jumper J1.

Verify PIR coverage and adjust if required.

2) Select MICROWAVE channel on jumper J1.

Verify MICROWAVE coverage and adjust if required.

3) Select DUAL processing on jumper J1 and verify unit detection.

LED JUMPER AND REMOTE CONTROL OF LED (Fig. 3).
(DD495/DD496).
Move jumper J3 to position OFF/REMOTE. The LED is now disabled. It may be
enabled by moving the jumper J3 to the ON position or remotely by applying a
0 V potential to terminal 8.

ALARM MEMORY (Fig. 3b & 4)
(DD497/DD498)
Note: First set the Control Voltage ("CV")  by jumper J2.

Connect "CV" to terminal 9 when the system is armed. When system is
disarmed, disconnect the "CV". If an alarm has occured during the armed
period, the detector or detectors which gave the alarm are indicated by a
flashing LED. Re-applying the "CV" (re-arming the system) will reset LED
indication and memory.

REMOTE ENABLE/DISABLE OF WALK TEST LED
To walk test the detector, the "CV" to terminal 9 (latch) must be disconnected.
Connect "CV" to terminal 10. The detector’s LED will now light and go out again
as the alarm relay opens and closes, making possible walk testing.

Note 1: Enabling the walk test will not clear alarm memory. After disarming the
system after an alarm, you may switch to walk test. When you switch back out
of walk test, the indication of memorized alarms will re-appear. Only when "CV"
is re-applied to terminal 9 (ie. system is re-armed) will LEDs and memory be
cleared.

Note 2: To enable the walk test LED without a remote "CV" input, connect a link
between terminal 2 and 10, J2 = "+".

MICROWAVE DISABLE
The DD497/DD498
 have the additional feature that whenever the

system is disarmed with the walk test off, the microwave transmitter will be
switched off. The detector will then operate as a PIR only. In all other con-
figurations the unit operates in dual technology mode.

SELECTING THE COVERAGE PATTERNS (Fig. 5-10)
Mask the appropriate mirror curtains with the adhesive labels provided and
reassemble the sensor module.

For example:
See Fig. 5 for mirror curtain coverage pattern corresponding to curtain 3A & 3B,
6A and 7B masked.

Removing label(s) can damage the mirrorsurface!

The coverage pattern can be changed to fit specific requirements using the
mirror masks as shown (Fig. 6-10). Mask off unused curtains which might
otherwise be looking at walls or windows very close to the detector.

WINDOW MASK (Fig. 11)
In the presence of objects close to (within 1.5 m) and directly under the detector,
fit the mask to the inside of the window.
This disables the part of the curtains looking at the object, whose closeness
might otherwise destabilize the detector.

Содержание DD490 Series

Страница 1: ... 1 NL D F I E GB DD495 UK DD496 UK DD497 UK DD498 UK Fig 2 Fig 3 a b c DD490 UK Series Dual Technology Detector Installation Manual Fig 1 Fig 1b ...

Страница 2: ... DD498 J2 then CV 12 Volt HIGH J2 then CV 0 Volt LOW Latch 12 V to terminal 9 Latch 0 V to terminal 9 Walk test 12 V to terminal 10 Walk test 0 V to terminal 10 Fig 4 Fig 5 Fig 8 Fig 9 Fig 10 Fig 11 Fig 6 Fig 7 ...

Страница 3: ...s of the protected area 1 Select PIR channel on jumper J1 Verify PIR coverage and adjust if required 2 Select MICROWAVE channel on jumper J1 Verify MICROWAVE coverage and adjust if required 3 Select DUAL processing on jumper J1 and verify unit detection LED JUMPER AND REMOTE CONTROL OF LED Fig 3 DD495 DD496 Move jumper J3 to position OFF REMOTE The LED is now disabled It may be enabled by moving t...

Страница 4: ...le canal IRP par le cavalier J1 Vérifier la détection IRP et ajuster au besoin 2 Selectionner le canal MICRO ONDES par le cavalier J1 Verifier la détection MICRO ONDES et ajuster au besoin 3 Selectionner le mode double technologie par le cavalier J1 et vérifier la bonne détection de l appareil CAVALIER DE LED ET CONTRÔLE DE LA LED À DISTANCE Fig 3 DD495 DD496 Mettre le cavalier J3 sur la position ...

Страница 5: ... detectieveld en wijzig indien nodig 2 Selecteer de RADAR optie op jumper J1 Verifieer RADAR detectieveld en wijzig indien nodig 3 Selecteer de DUAL techniek optie op jumper J1 Verifieer het detectieveld en wijzig indien nodig LED JUMPER EN SCHAKELEN VAN DE LED OP AFSTAND Fig 3 DD495 DD496 Zet jumperJ3 naar de positie OFF REMOTE De LED is nu uitgeschakeld Deze kan weer worden ingeschakeld door de ...

Страница 6: ...el und Sockel angebracht werden Die VOID Plombier siegel können unter Bestellnummer Aritech VS200 50 Siegel bestellt werden Es darf nur ein DD455 DD456 DD475 DD476 DD495 und DD496 ohne Alarmspeicher an eine Meldegruppe angeschaltet werden Deutsch MONTAGEANLEITUNG Abb 1 1 Nehmen Sie die Abdeckplatte À À À À À wie dargestellt ab 2 Öffnen Sie den Melder Á Á Á Á Á und nehmen Sie das Elektronik Modul Â...

Страница 7: ... m 12 m portata media fino a 12 m 7 m portata minima fino a 7 m Selezionate sempre la portata minima in funzione delle dimensioni dell area da proteggere 1 Selezionare il canale INFRAROSSO con il cavallotto J1 Verificare la portata e regolate se necessario 2 Selezionare il canale MICROONDA con il cavallotto J1 Verificare la portata e regolate se necessario 3 Selezionare la funzione DOPPA tecnologi...

Страница 8: ...los agujeros de montaje para una esquina Å Å Å Å Å o para una pared Æ Æ Æ Æ Æ 6 Utilice la base como placa para marcar los agujeros a realizar en la pared 7 Fije la base a la pared 8 Pelar 5 cm el cable e introducirlo a través de la s entradas Ä Ä Ä Ä Ä previstas para ello È È È È È 9 Vuelva a colocar en su lugar el módulo electrónico      y conecte el cable al sensor como se indica en la fig...

Страница 9: ...ntimanomis Walk test abilitare il LED Potenza max microonda a 50 cm Emissione continua Limiti di temperatura Umidità relativa Dimensioni Peso Numero di zone Visione angolare Portata del sensore Scatola conforme a con ingresso di cavo sigillato NESSUNA restrizione d uso NON consentito l uso in Francia Irlanda e Regno Unito OmologatoIMQII Livello per la conformità alle norme CEI 79 2 è necesssario l...

Страница 10: ... 10 3690 2A Aritech is an Interlogix company 2002 All rights reserved C version Non C version ...

Отзывы: