6
7000 300 en 00
2.4 Instruction for emergency opening of door
The mains isolator should always be switched off before opening of any door during a
power failure to avoid injury to personnel.
N.B.
The lift shall only be evacuated if the it is close to a landing. If not the lift must be
lowered, See “Instruction for emergency lowering of the platform” on page 4.
WARNING
Note the risk of falling when the door is open. Always keep the doors closed and
check the function of the lock so nobody can fall into the shaft.
With triangle key:
•
Open the cabinet with the triangle key and switch off the main power in the
electrical cabinet. The switch is marked ‘Lift machinery’.
•
Put the triangle-key in the hole in the door panel, see
. Turn the key.
Figure 2-3. Triangle key with hole
•
When the triangle-key is turned, the door can be opened.
•
Close the door when the platform is empty.
•
Reset any alarm when the platform is empty. The switch is located in the electrical
cabinet and marked ’Alarm Reset’.
•
Close and lock the electrical cabinet.
N.B.
Make sure that the function of the lift is normal.
•
Switch on the mains power supply.
Содержание 7000 Series
Страница 3: ......
Страница 4: ...Simply platform lifts 20110609 ARITCO Control System 7000 series Document number 7000 400 en 01 ...
Страница 12: ...Simply platform lifts 20110609 ARITCO 9 6 Front panel ...
Страница 17: ...Simply platform lifts 20110609 ARITCO 14 10 Error diagram ...
Страница 20: ...Simply platform lifts 20110609 ARITCO 17 Attachment 2 Cabin Attachment 3 Mast ...
Страница 21: ...Simply platform lifts 20110609 ARITCO 18 Attachment 4 Cabinet 400 230V Attachment 5 Cabinet frequency ...
Страница 25: ...20110609 ARITCO 22 Attachment 9 ...
Страница 26: ...20110609 ARITCO 23 Attachment 10 ...
Страница 27: ...20110609 ARITCO 24 Attachment 11 ...
Страница 28: ...Simply platform lifts 20110609 ARITCO 25 ...
Страница 30: ...Maintenance Manual for platform lifts within the 7000 series Document number 7000 300 en 00 ...
Страница 33: ...ii 7000 300 en 00 This page is intentionally left blank ...
Страница 35: ...iv 7000 300 en 00 This page is intentionally left blank ...
Страница 64: ......
Страница 66: ...Users Manual for platform lifts within the 7000 series Document number 7000 200 en 01 ...
Страница 69: ...ii 7000 200 en 01 This page is intentionally left blank ...
Страница 83: ...14 7000 200 en 01 This page is intentionally left blank ...
Страница 84: ......
Страница 85: ...Aritco Lift AB Box 18 S 196 21 Kungsängen SWEDEN Telephone 46 0 8 120 401 00 Telefax 46 0 8 120 401 99 ...