55
maintenance guide
3.14 TEMPERATURE SENSORS & OVERHEAT THERMOSTAT
TEMPERATURE SENSORS & OVERHEAT THERMOSTAT
Tools
Time
5 min
1
Unplug the electrical connectors
Remove the clips and the
temperature sensor or
overheat thermostat together
IMPORTANT!!!!
Do not use conducting paste for the contact sensors because it will alter the resistance value.
TEMPERATURE (°C)
RESISTANCE (kOmh)
0
27
10
17
20
12
25
10
30
8
40
5
50
4
60
3
70
2
80
1,5
Temperature sensors & overheat thermostat
Содержание Clas 24 FF
Страница 23: ...23 installation WIRING DIAGRAM FOR CONNECTION TO AN OPEN VENTED CYLINDER ...
Страница 24: ...24 installation WIRING DIAGRAM FOR CONNECTION TO AN MTS UNVENTED CYLINDER ...
Страница 57: ...57 maintenance guide 4 BURNER UNIT Burner unit ...
Страница 64: ......