![Ariston Clas 24 FF Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/ariston/clas-24-ff/clas-24-ff_installation-and-servicing-instructions_2970940010.webp)
10
installation
Mounting the Appliance
After removing the boiler from its packaging, remove the template
from the box. Note: Pay particular attention to any test water that
may spill from the appliance.
Place the template in the position the appliance is to be mounted
and after ensuring it is hanging squarely, use it to drill the holes for
the hanging bracket and fl ue pipe(s) NB: For further information
relating to the fl ue installation please refer to
Flue Installation -
page 13
. (If the appliance is to be fi tted on a wall of combustible
material, the wall must be protected by a sheet of fi reproof
material).
If the appliance is to be fi tted into a timber framed building,
guidance should be sought from the Institute of Gas Engineers
document Ref: IGE/UP/7.
Drill the wall and plug using those supplied with the connections
kit, position the hanging bracket and secure with the wall bolts
supplied, assembl the connection kit and secure to the wall.
Position the appliance on the hanging bracket and connect the
valves to the boiler connections. (see also
Gas Connections
,
Water
Connections - page 11
).
Electrical Connection
For safety purposes, have a competent person carefully check the
electrical system in the property, as the manufacturer will not be
held liable for damage caused by the failure to earth the appliance
properly or by anomalies in the supply of power. Make sure that
the residential electrical system is adequate for the maximum
power absorbed by the unit, which is indicated on the rating
plate. In addition, check that the section of cabling is appropriate
for the power absorbed by the boiler.
The boiler operates with alternating current, as indicated in
the Technical Information tables on pages 6 and 7, where the
maximum absorbed power is also indicated. Make sure that the
connections for the neutral and live wires correspond to the
indications in the diagram. The appliance electrical connections
are situated on the reverse of the control panel.
Important!
In the event that the power supply cord must be changed, replace
it with one with the same specifi cations.
Note: The diagrams for the electrical system and external wiring
confi gurations can be found on pages ?? and ??.
Should external controls be required, the design of the external
electrical circuits should be undertaken by a competent person.
Warning, this appliance must be earthed.
External wiring to the appliance must be carried out by a
competent person and be in accordance with the current I.E.E.
Regulations and applicable local regulations.
The appliance is supplied with a fl y-lead already connected,
this must be connected to a 240v supply fused at 3A and must
facilitate complete electrical isolation of the appliance, by the use
of a fused double pole isolator having a contact separation of at
least 3 mm in all poles or alternatively, by means of a 3 A fused
three pin plug and unswitched shuttered socket outlet both
complying with BS 1363.
The point of connection to the Electricity supply must be readily
accessible and adjacent to the appliance unless the appliance
is installed in a bathroom when this must be sited outside the
bathroom.
400
65
67
67
65
120
120
ø80
ø80
ø80
ø100
770
250
580
830
105
195
90
725
1/2"
1/2"
3/4"
3/4"
3/4"
195
105
120
180
105
315
150
180
315
150
ø 80 + ø 80
ø 60/100 - ø 80/125
300
50
20
330
Fig. 7