38
The boiler is delivered with pre-set values described
in menus 3 and 4.
All settings must only be changed by the installer or
a qualified person. To gain access to the setting
buttons please, open the front control panel cover
P) and follow the instructions below.
17. Adjustments and settings
DISPLAY
2nd digit
P
1st digit
3rd digit
4th digit
On/Off push button
Reset push button
Menu button
- button
+ button
Setting button
11
22
33
44
55
66
77
88
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
1818
1919
2020
2121
2222
23
23
24
24
99
66
12
12
I
Pressing the, comfort, reset, menu, +, -, or setting buttons will make the display light. The light will go out 30 seconds after the
last button has been pressed.
To gain access to the setting menus press
and
buttons together for 5 seconds.. Menu 1 is displayed on the 1st digit.
Changing the menu :
Press the Menu button
. The menu number is displayed for 3 seconds. Press the menu button to change to the next
menu
Setting a parameter in a section :
Press the
or
button to change from between sections.
Note : When you arrive at the last section of a menu, pressing the
button will change to the the 1st section. When
you are at the first section, pressing the
button will change to the last section of the menu.
Changing section in a menu (available only for menu 3,4,5 and 6)
:
Press the setting button
to enter the modification mode, The 3rd and 4th digits will be flashing, press the
or
button to select the correct value then press the setting button to select this modification and to exit the setting mode. The
3rd and 4th digit stop flashing.
Recalling the basic configuration :
Select menu 3,4,5 or 6 then press the
and
buttons together for more than 5 seconds. The digits will flash CM for
a while to indicate that the operation is completed.
Clearing Menu 1 (default register) :
Select menu 1 then press the
and
buttons together for more than 5 seconds. The digits will flash CM for a while
to indicate that the operation is completed.
Note : To exit install mode, press the Menu button
for at least 3s. If no button is pressed for about 1 minute, the display
returns to user mode.
Содержание Benchmark System A 24 RFF
Страница 18: ...18 1 2 A A Fig 13 Fig 15 Fig 12 11 Installing the Boiler continued Fig 14 P P ...
Страница 21: ...21 Fig 20 Fig 21 Fig 22 162 ...
Страница 30: ...30 WIRING DIAGRAM FOR CONNECTION TO AN OPEN VENTED CYLINDER DIAGRAM B ...
Страница 31: ...31 WIRING DIAGRAM FOR CONNECTION TO AN MTS UNVENTED CYLINDER DIAGRAM A ...
Страница 60: ...60 ...