background image

lp-772 Rev. 000 Rel. 000 Date 3.17.21

4

Approximate Time / Temperature Relationships in Scalds

120

o

F

More than 5 minutes

125

o

F

1 1/2 to 2 minutes

130

o

F

About 30 seconds

135

o

F

About 10 seconds

140

o

F

Less than 5 seconds

145

o

F

Less than 3 seconds

150

o

F

About 1 1/2 seconds

155

o

F

About 1 second

Table 1 - Approximate Time / Temperature Relationships in Scalds

Part 2 - Prepare the Water Heater

COLD WEATHER HANDLING

 - If the water heater has been stored 

in a very cold location (BELOW 0

o

F) before installation, handle with 

care until the components come to room temperature. Failure to do 

so could result in damage to the water heater.

Remove all sides of the shipping crate to allow the heater to be moved 

into its installation location.

A. What’s in the Box

Components included with the water heater:

•  Drain Valve

•  Temperature and Pressure Relief Valve

•  Use and Care Manual and Warranty

NOTE:

 Some components may ship factory installed.  

B. Locating the Water Heater

All water heaters eventually leak. Locate the water heater where any 

leakage from the relief valve, related piping, tank, or connections 

will not result in damage to surrounding areas or lower floors of the 

building. Any water heater should be installed in such a manner that 

if it should leak the resulting flow of water will not cause damage 

to the area in which it is installed. National Plumbing codes require 

a drain pan for any water heater installation. This drain pan should 

be sized with a maximum depth of 2”, and a minimum diameter 

2” greater than the diameter of the water heater. The drain pan 

should empty into an open drain line. This drain line should be 

3/4” ID minimum, piped to an open drain. Leakage damages ARE 

NOT covered by warranty. Failure to install a drain pan is the sole 

responsibility of the owner and/or installer. Reference UPC 2000 

(Uniform Plumbing Code) Section 510 - Protection from Damage or 

IPC 200 (International Plumbing code) Section 504 - Safety Devices. 

Leakage damages ARE NOT covered by warranty.

In addition, water leak detection devices and automatic water shutoff 

valves are readily available at plumbing supply houses. IT IS HIGHLY 

RECOMMENDED BY THE MANUFACTURER TO INSTALL WATER LEAK 

DETECTION DEVICES AND AUTOMATIC SHUTOFF VALVES IN ANY 

WATER HEATER INSTALLATION WHERE A LEAKAGE OF WATER COULD 

RESULT IN PROPERTY DAMAGES. 

This water heater is certified for indoor use only. DO NOT INSTALL 

OUTDOORS. Outdoor installations ARE NOT covered by warranty. 

Failure to install the water heater indoors could result in property 

damage, severe personal injury, or death.

2. Choose a location for the water heater as centralized to the piping 

and electrical system as possible. Also, locate the water heater and 

domestic water piping where it will not be exposed to freezing 

temperatures. All piping should be insulated. Additionally, place the 

water heater so that the drain, controls, and inlets/outlets are easily 

accessible.

NOTE: 

To save on heating costs and improve energy efficiency keep 

the distance between the water heater and fixtures to a minimum 

to reduce heat loss from excess piping and keep friction loss at a 

minimum. Ensure all water heater piping is properly insulated to 

minimize heat loss.

NOTE: 

If you do not provide the minimum clearances shown in 

Figure 1, it might not be possible to service the water heater without 

removing it from the space. 

NOTE: 

A combustible door or removable panel is acceptable front 

clearance.

NOTE:

 In the State of California, the water heater must be braced, 

anchored, or strapped to avoid moving during an earthquake. 

Contact local utilities for code requirements in your area. Visit 

http://www.dsa.dgs.ca.gov or call 1-916-445-8100 and request 

instructions.
However, applicable local codes shall govern installation. For 

residential water heaters of a capacity of greater than 52 gallons, 

consult the local building jurisdiction for acceptable bracing 

procedures.
3. Check area around water heater. Remove any combustible 

materials, gasoline, and other flammable liquids.

1. Installation Area (Mechanical Room) Operating Conditions

•  Ensure ambient temperatures are higher than 32

o

F / 0

o

C and 

lower than 104

o

F / 40

o

C

•  Avoid continuously high levels of humidity
•  Never close existing ventilation openings

NOTE:

 When installing in a zero clearance location, it may not be 

possible to read or view some product labeling. It is recommended 

to make note of the water heater model and serial number.

The service life of the water heater’s exposed metallic surfaces, such 

as the junction box, is directly influenced by proximity to damp 

and salty marine environments. In such areas higher concentration 

levels of chlorides from sea spray coupled with relative humidity 

can lead to degradation of water heater components.

Incorrect operating conditions can lead to damage to the heating 

system and put safe operation at risk. Ensure that the installation 

location adheres to the information included in this manual. 

Failure to do so could result in property damage, serious personal 

injury, or death. Failure of the water heater or components due 

to incorrect operating conditions IS NOT covered by product 

warranty.

This water heater must be installed upright in the vertical position 

as described in this manual. DO NOT attempt to install this water 

heater in any other orientation. Doing so will result in improper 

water heater operation and property damage, and could result in 

serious personal injury or death.

Households with small children, disabled, or elderly persons may 

require a 120

o

F or lower temperature setting to prevent severe 

personal injury or death due to scalding.

Содержание ARI POU-06

Страница 1: ...hical errors in literature NOTE TO CONSUMER PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE 272 Duchaine Blvd New Bedford MA 02745 ariston com lp 772 Rev 000 Rel 000 Date 3 17 21 The surfaces of these products contacted by potable consumable water contain less than 0 25 lead by weight as required by the Safe Drinking Water Act Section 1417 Use and Care Manual California Proposition 65 Warning Th...

Страница 2: ...ding details 3 Install or locate this water heater only in accordance with the provided installation instructions 4 Use this water heater only for its intended use as described in this manual 5 Do not operate this water heater if it has been damaged or dropped 6 This water heater should be serviced only by qualified service personnel Contact the water heater installer or a qualified service agency...

Страница 3: ...Heating Element Replacement Procedure 12 D Anode Rod 13 Part 7 Maintenance 13 Part 8 Troubleshooting 15 Part 9 Replacement Parts 16 Six 6 Year Limited Warranty 17 Customer Installation Record Form 19 Do not use this water heater for anything other than its intended purpose as described in this manual Doing so could result in property damage and WILL VOID product warranty A When Servicing the Water...

Страница 4: ...nd domestic water piping where it will not be exposed to freezing temperatures All piping should be insulated Additionally place the water heater so that the drain controls and inlets outlets are easily accessible NOTE To save on heating costs and improve energy efficiency keep the distance between the water heater and fixtures to a minimum to reduce heat loss from excess piping and keep friction ...

Страница 5: ...r treatment is recommended and additional more frequent maintenance may be required If you suspect that your water is contaminated in any way discontinue use of the appliance and contact an authorized technician or licensed professional Water pH between 6 5 and 8 5 pH levels below 6 5 can cause an increase in the rate of corrosion pH of 8 5 or higher can potentially cause lime scale build up Maint...

Страница 6: ...3500 35 8 28 7 23 9 20 5 17 9 16 2 14 5 4000 41 0 32 8 27 3 23 4 20 5 18 5 16 4 4500 46 1 36 8 30 7 26 4 23 0 20 7 18 4 5000 51 2 41 0 34 1 29 3 25 6 23 1 20 5 5500 56 4 45 1 37 5 32 2 28 2 25 4 22 5 6000 61 4 49 2 41 0 35 1 30 7 27 3 24 6 Table 2 Electrical Characteristics Table 3 GPH Recovery Figure 2 Dimensional Drawing Table 4 Specifications and Dimensions Model ARI POU 06 120V 1500W ARI POU 1...

Страница 7: ...he water heater Do not cover the operating or warning labels attached to the water heater or attempt to locate them on the exterior of the insulation blanket Do not apply insulation to the top of the water heater This could interfere with the safe operation of the electrical junction box Do not cover the jacket access panel to the thermostat and heating element or T P valve Inspect the insulation ...

Страница 8: ...rate correctly immediately replace with a new properly rated relief valve Test T P valve at least once annually to ensure the waterway is clear If valve does not operate turn the heater off and call a plumber immediately Take care whenever operating relief valve to avoid scalding injury or property damage FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD RESULT IN FAILURE OF RELIEF VALVE OPERATION...

Страница 9: ...afest water temperature for your applications I Applications TOP OPTION INSTALLATION Figure 4 Piping Details NOTE Drawings are meant to demonstrate system piping concept Heat traps are optional but recommended PIPING NOTES The following notes are applicable to all of the piping applications demonstrated on this page 1 Minimum pipe size should match connection size Upsize pipe accordingly if greate...

Страница 10: ... in size may be required D This water heater must be properly grounded A ground lug is provided within the electrical control box for connection of a properly sized ground E Close the cover door of the wiring connection box Part 4 Wiring All wiring must conform to local codes and or the latest edition of National Electrical Code ANSI NFPA 70 Refer to wiring diagrams in this manual for proper wirin...

Страница 11: ...Sufficient room to service heater Relief Valve Yes No Temperature and Pressure Relief Valve properly installed and discharge line run to open drain Discharge line protected from freezing Wiring Yes No Power supply voltage agrees with water heater rat ing plate Branch circuit wire and fusing or circuit breaker of proper size Electrical connections tight and unit properly grounded Water Supply Yes N...

Страница 12: ... of water before the power is turned on The heating element will be damaged if energized for even a short time while tank is dry Failures due to dry firing ARE NOT covered by warranty A Combination Thermostat and High Limit Control ECO After water and electrical connections have been made and tank is filled with water turn on power to the heater The heater is now in operation Each water heater is ...

Страница 13: ...intenance NOTE In addition to the routine maintenance detailed in this manual this water heater should be inspected annually by a qualified service technician to assure that all the equipment is operating safely and efficiently The owner should make necessary arrangements with a qualified heating contractor for periodic maintenance of the heater Installer must also inform the owner that lack of pr...

Страница 14: ...O NOT replace the water heater until full inspections of all possible water sources are determined and necessary corrective steps have been taken NOTE To check the fitting threads insert a cotton swab between the jacket opening and fitting If the cotton is wet follow the drain ing instructions in the Maintenance section of this manual Then re move the fitting Put pipe dope or Teflon tape on the th...

Страница 15: ...ough Hot Water Heater undersized Reduce rate of heater use Defective element Check amperage replace element if low Miswired or defective thermostat causing only one element to work Check wiring or replace thermostat Water Too Hot or Not Hot Enough Thermostat setting too high or low Change setting as required Thermostat out of calibration Replace thermostat Thermostat access panel not in place Insp...

Страница 16: ...tomer service please have ready 1 The water heater model serial number and electrical specifications voltage and wattage as marked on the rating plate 2 The part description as noted above and number of parts desired DO NOT attempt to repair electrical wiring thermostats heating elements or other operating controls Refer such repairs to qualified ser vice personnel Failure to do so could result in...

Страница 17: ...in accordance with federal state and local codes and in installations prone to vacuum related damages 3 Maintain the water heater in accordance with the maintenance procedure listed in the manufacturer s provided instructions Preventive maintenance can help avoid any unnecessary breakdown of the water heater and keep it running at optimum efficiency 4 Maintain all related system components in good...

Страница 18: ...facturer shall be liable for and shall pay for all charges for labor or other expenses incurred in the removal repair or replacement of the appliance or any component part s claimed to be defective or any expense incurred to remedy any defect in the product Such charges include but are not necessarily limited to 1 All freight shipping handling and delivery costs of forwarding a new appliance or re...

Страница 19: ...tallation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer Installation Notes IMPORTANT Customer Please only sign after the Qualified Installer Service Technician has fully reviewed the installation safety proper operation and maintenance of the system If the system has any problems please call the Quali...

Отзывы: