background image

lp-772 Rev. 000 Rel. 000 Date 3.17.21

13

Step #7

 - Open the main cold water inlet. If the water heater has 

been isolated from the system, open the valves. Refill the tank with 

cold water. Open a hot water faucet high in the system to bleed 

any air pressure from the system. Water will flow freely when air is 

completely bled.

When filling the water heater, open a hot water tap to release air 

in the tank and piping. The tank must be full of water before the 

heater is turned on. Failure to ensure the water heater is full before 

turning it on will result in damage to the water heater, and could 

result in property damage, serious personal injury, or death. Such 

damages ARE NOT covered by water heater warranty.

Step #8

 - Pressure check the tank for leaks around element. If no 

leaks are found, use a Phillips Head screwdriver to connect the wires 

to the element.

Step #9

 - Turn power back on to the water heater.

Failure to refill the tank before restoring power to the water 

heater will result in damage to the heating element and property 

damage. Such damages ARE NOT covered by  warranty.

Completely drain the water heater before removing and replacing 

a heating element. Failure to do so will result in a leakage of water 

and property damage, and could possibly result in moderate to 

severe personal injury or death.
Water drained from the water heater may be scalding hot. Take 

care to avoid scalding. Wear gloves and safety glasses, and direct 

water to a safe drainage location. Failure to comply with this 

warning could result in property damage, severe personal injury, 

or death.

Step #3

 - Remove the element with a 1 1/2” socket wrench or 

element tool.

Step #4

 - Ensure thread and opening are completely free of debris. 

Use a nylon brush to clear away any debris.

Step #5

 - Put a small amount of NSF approved lubricant and sealant 

on the appropriate gasket and/or washer for the installation. Put the 

gasket and/or washer on the element.

Step #6

 - Screw the element clockwise into the tank, and tighten 

with the 1 1/2” socket wrench or element tool. Be sure O-ring seats 

properly.

D. Anode Rod

This water heater is equipped with a magnesium anode rod. Anode 

rods are sacrificial components that counteract water chemistry to 

minimize or eliminate tank corrosion.

The anode rod should be inspected annually and replaced as 

necessary to prolong tank life. Have the supply water quality 

professionally analyzed, as local water conditions will influence the 

duration for inspection and replacement of the anode rod.

The use of a water softener may increase the speed of anode 

consumption. More frequent inspection of the anode is needed 

when using softened or treated water.

Water with high sulfate and/or mineral content can produce a 

rotten egg odor in heated water. Chlorinating the water supply may 

minimize this problem.

NOTE: 

Do not remove the anode rod from an operating water 

heater. Operating the water heater without the anode rod will 

shorten the life of the tank and VOID the warranty.

Part 7 - Maintenance

Considerations

• 

To avoid electric shock, disconnect electrical supply before 

performing maintenance.

• 

To avoid severe burns, allow heater to cool before performing 

maintenance.

NOTE:

 In addition to the routine maintenance detailed in this manual, 

this water heater should be inspected annually by a qualified service 

technician to assure that all the equipment is operating safely and 

efficiently. The owner should make necessary arrangements with a 

qualified heating contractor for periodic maintenance of the heater. 

Installer must also inform the owner that lack of proper care and 

maintenance may result in a hazardous condition, premature heater 

failure, and void the warranty.

Routine preventative maintenance ensure the water heater operates 

safely and efficiently over its service life. The 

Owner / User

 may 

perform the maintenance activities described below.

Monthly (Every two weeks in hard water locations)

It is recommended that a few quarts of water be drained from the 

heater. This will flush sediment deposits from the bottom of the heater 

and lengthen the heater’s service life. Turn off power to the heater 

during flushing operation, so the elements will not be damaged.

Failure to shut off the heater when draining may damage the heating 

element. Operating a partially filled / empty water heater could lead 

to damage from “dry-firing”. Failures due to such damage ARE NOT 

covered by warranty.

To flush the tank, attach a hose to the field installed drain valve. Close 

the cold water supply line shut-off valve. Open the drain valve and hot 

water faucet(s) to vent heater while draining. Direct the flow of water 

to a drain or bucket where it will not cause damage.

Flush until water runs clear to complete this operation. Close drain 

valve and reopen the supply line shut-off valve. Close the hot water 

faucet(s) once all air has been bled from the system (when water runs 

freely). Make certain that the heater is completely full of water before 

restoring power.

Periodically (At least twice a year)

Check around the water heater and related plumbing for leaks. If 

the combination temperature and pressure relief valve discharges 

periodically, or water is leaking from around the heating elements, 

there may be a problem with your water system. DO NOT ATTEMPT 

TO REPAIR LEAKS YOURSELF! Contact a qualified service contractor for 

assistance.

Check the area around the water heater for flammable liquids or 

combustible materials. If any are found, remove from the area.

Vacation (Extended shut-off periods)

During extended mild or warm weather periods when hot water will 

not be in use, shut off the electric power to the tank. When hot water is 

needed again, restore power to the water heater.

During extended cold weather periods when hot water will not be 

in use and prone to freezing conditions, shut off electric power to 

the tank, close the supply line shut-off valve, open the drain valve 

and drain the water heater to a safe drainage location (as detailed 

previously). Once drained, close the drain valve. When hot water is 

needed again, restore the water supply to the tank. Once the tank is 

full, restore power.

Water drained from the water heater may be scalding hot. Take care 

to avoid scalding. Wear gloves and safety glasses, and direct water to 

a safe drainage location. It is recommended to turn power off to the 

water heater and run water at a hot water faucet until it cools BEFORE 

draining water from the heater. Failure to comply with this warning 

could result in property damage, severe personal injury, or death.

Содержание ARI POU-06

Страница 1: ...hical errors in literature NOTE TO CONSUMER PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE 272 Duchaine Blvd New Bedford MA 02745 ariston com lp 772 Rev 000 Rel 000 Date 3 17 21 The surfaces of these products contacted by potable consumable water contain less than 0 25 lead by weight as required by the Safe Drinking Water Act Section 1417 Use and Care Manual California Proposition 65 Warning Th...

Страница 2: ...ding details 3 Install or locate this water heater only in accordance with the provided installation instructions 4 Use this water heater only for its intended use as described in this manual 5 Do not operate this water heater if it has been damaged or dropped 6 This water heater should be serviced only by qualified service personnel Contact the water heater installer or a qualified service agency...

Страница 3: ...Heating Element Replacement Procedure 12 D Anode Rod 13 Part 7 Maintenance 13 Part 8 Troubleshooting 15 Part 9 Replacement Parts 16 Six 6 Year Limited Warranty 17 Customer Installation Record Form 19 Do not use this water heater for anything other than its intended purpose as described in this manual Doing so could result in property damage and WILL VOID product warranty A When Servicing the Water...

Страница 4: ...nd domestic water piping where it will not be exposed to freezing temperatures All piping should be insulated Additionally place the water heater so that the drain controls and inlets outlets are easily accessible NOTE To save on heating costs and improve energy efficiency keep the distance between the water heater and fixtures to a minimum to reduce heat loss from excess piping and keep friction ...

Страница 5: ...r treatment is recommended and additional more frequent maintenance may be required If you suspect that your water is contaminated in any way discontinue use of the appliance and contact an authorized technician or licensed professional Water pH between 6 5 and 8 5 pH levels below 6 5 can cause an increase in the rate of corrosion pH of 8 5 or higher can potentially cause lime scale build up Maint...

Страница 6: ...3500 35 8 28 7 23 9 20 5 17 9 16 2 14 5 4000 41 0 32 8 27 3 23 4 20 5 18 5 16 4 4500 46 1 36 8 30 7 26 4 23 0 20 7 18 4 5000 51 2 41 0 34 1 29 3 25 6 23 1 20 5 5500 56 4 45 1 37 5 32 2 28 2 25 4 22 5 6000 61 4 49 2 41 0 35 1 30 7 27 3 24 6 Table 2 Electrical Characteristics Table 3 GPH Recovery Figure 2 Dimensional Drawing Table 4 Specifications and Dimensions Model ARI POU 06 120V 1500W ARI POU 1...

Страница 7: ...he water heater Do not cover the operating or warning labels attached to the water heater or attempt to locate them on the exterior of the insulation blanket Do not apply insulation to the top of the water heater This could interfere with the safe operation of the electrical junction box Do not cover the jacket access panel to the thermostat and heating element or T P valve Inspect the insulation ...

Страница 8: ...rate correctly immediately replace with a new properly rated relief valve Test T P valve at least once annually to ensure the waterway is clear If valve does not operate turn the heater off and call a plumber immediately Take care whenever operating relief valve to avoid scalding injury or property damage FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD RESULT IN FAILURE OF RELIEF VALVE OPERATION...

Страница 9: ...afest water temperature for your applications I Applications TOP OPTION INSTALLATION Figure 4 Piping Details NOTE Drawings are meant to demonstrate system piping concept Heat traps are optional but recommended PIPING NOTES The following notes are applicable to all of the piping applications demonstrated on this page 1 Minimum pipe size should match connection size Upsize pipe accordingly if greate...

Страница 10: ... in size may be required D This water heater must be properly grounded A ground lug is provided within the electrical control box for connection of a properly sized ground E Close the cover door of the wiring connection box Part 4 Wiring All wiring must conform to local codes and or the latest edition of National Electrical Code ANSI NFPA 70 Refer to wiring diagrams in this manual for proper wirin...

Страница 11: ...Sufficient room to service heater Relief Valve Yes No Temperature and Pressure Relief Valve properly installed and discharge line run to open drain Discharge line protected from freezing Wiring Yes No Power supply voltage agrees with water heater rat ing plate Branch circuit wire and fusing or circuit breaker of proper size Electrical connections tight and unit properly grounded Water Supply Yes N...

Страница 12: ... of water before the power is turned on The heating element will be damaged if energized for even a short time while tank is dry Failures due to dry firing ARE NOT covered by warranty A Combination Thermostat and High Limit Control ECO After water and electrical connections have been made and tank is filled with water turn on power to the heater The heater is now in operation Each water heater is ...

Страница 13: ...intenance NOTE In addition to the routine maintenance detailed in this manual this water heater should be inspected annually by a qualified service technician to assure that all the equipment is operating safely and efficiently The owner should make necessary arrangements with a qualified heating contractor for periodic maintenance of the heater Installer must also inform the owner that lack of pr...

Страница 14: ...O NOT replace the water heater until full inspections of all possible water sources are determined and necessary corrective steps have been taken NOTE To check the fitting threads insert a cotton swab between the jacket opening and fitting If the cotton is wet follow the drain ing instructions in the Maintenance section of this manual Then re move the fitting Put pipe dope or Teflon tape on the th...

Страница 15: ...ough Hot Water Heater undersized Reduce rate of heater use Defective element Check amperage replace element if low Miswired or defective thermostat causing only one element to work Check wiring or replace thermostat Water Too Hot or Not Hot Enough Thermostat setting too high or low Change setting as required Thermostat out of calibration Replace thermostat Thermostat access panel not in place Insp...

Страница 16: ...tomer service please have ready 1 The water heater model serial number and electrical specifications voltage and wattage as marked on the rating plate 2 The part description as noted above and number of parts desired DO NOT attempt to repair electrical wiring thermostats heating elements or other operating controls Refer such repairs to qualified ser vice personnel Failure to do so could result in...

Страница 17: ...in accordance with federal state and local codes and in installations prone to vacuum related damages 3 Maintain the water heater in accordance with the maintenance procedure listed in the manufacturer s provided instructions Preventive maintenance can help avoid any unnecessary breakdown of the water heater and keep it running at optimum efficiency 4 Maintain all related system components in good...

Страница 18: ...facturer shall be liable for and shall pay for all charges for labor or other expenses incurred in the removal repair or replacement of the appliance or any component part s claimed to be defective or any expense incurred to remedy any defect in the product Such charges include but are not necessarily limited to 1 All freight shipping handling and delivery costs of forwarding a new appliance or re...

Страница 19: ...tallation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer Installation Notes IMPORTANT Customer Please only sign after the Qualified Installer Service Technician has fully reviewed the installation safety proper operation and maintenance of the system If the system has any problems please call the Quali...

Отзывы: