USA MAV500/MKVI Service Manual
Coin Chute Assembly
28-00486-00
6-13
This document contains confidential information which is proprietary to ATI. It may not be disclosed to any unauthorized parties,
and it may not be copied. All rights reserved.
© Copyright (ATI) Aristocrat Technologies, Inc. 2002.
Diagnostics
At power up, the validator automatically runs a self-diagnostic test on the following
critical areas:
•
Inductive Coils
•
Reflective Sensors
•
Diameter Opto Sensors
•
Credit Opto Sensors
If there is a failure in any one of these areas, the LED will flash red continuously and
the validator will not accept any coins until power is removed and the fault condition
corrected.
Debris Flap
The CP133S Validator incorporates a debris flap that allows direct access to the coin
path for inspection and the clearance of coin jams.
6.3.2 Removal and Replacement
To remove the validator:
1.
Open the cabinet door, and switch OFF the machine.
2.
Carefully unplug the loom from the validator. Do not pull on the wires.
3.
Push the assembly upwards, to the full extent of the top-locating groove. This
action causes the validator to come free of the bottom-locating groove.
4.
Swing the bottom of the unit outwards.
5.
Pull the validator downwards and clear of the coin chute assembly.
To replace the coin validator, reverse the above procedure.