10
0/1
Jog Right
operation
0: if the web guide is not jogging right
1: if the web guide is jogging right
11
0/1
Servo Centering
operation
0: if the web guide is not servo centering
1 if the web guide is servo centering
12
0/1
Good guiding
performance
0: if the guiding performance is not good
1: if the guiding performance is good
13-15
NA
Reserved for future use
Guide point percentage
The guide point for the web guide is provided in this register. 16-bit signed integer guidepoint offset is
provided in this register. When the guide point is changed on the screen or through the remote industrial
ethernet interface, this register can be used to verify the change.
Actuator speed percentage
The positioning speed of the actuator as a percentage of maximum speed is provided in most significant bits
of register 7. The value ranges between 0 and 100.
Actuator acceleration percentage
The acceleration of the actuator as a percentage of maximum acceleration is provided in the least significant
bits of register 7. The value ranges between 0 and 100.
Sensor 1 Thread Count
When multiple webs or strings or threads are viewed by the sensor, the number or the count of threads is
provided in the register.
Sensor 2 Thread Count
When multiple webs or strings or threads are viewed by the sensor, the number or the count of threads is
provided in the register.
Sensor 1 /Sensor 2 Web Width
When the SCU5 controller is set to provide the width, these registers provide the width output from the
controller. Registers 14 and 15 are combined to provide a 32-bit value. The most significant 16-bits are
provided in register 14 and the least significant 16-bits are provided in register 15.
Content subject to change without notice
SCU5: Sensor and Web Guide Controller User Manual v 3.6| Page 52
Copyright © 2021 Roll-2-Roll Technologies LLC
+1-888-290-3215