Installation Instructions
Prepare Location
• It is recommended that the vent system be installed before
the range hood is installed.
• Before making cutouts, make sure there is proper clearance
within the ceiling or wall for vent fittings.
• Making the cutout to the bottom of the cabinet may be easier
to do prior to mounting the cabinet to the wall.
1.
Disconnect power.
2.
Determine which venting method to use: roof, wall, or non
vented.
3.
Select a flat surface for assembling the range hood. Place
covering over that surface.
WARNING:
Excessive Weight Hazard.
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
4.
Using 2 or more people, lift range hood onto covered surface
Range Hood Cabinet Cutout
1.
Use a saber saw or keyhole saw to cut out the cabinet bottom
inside the cabinet frame.
NOTE: Frameless type cabinets require ¾” (1.9 cm) front lip
in the cabinet bottom.
2.
Cut out dimensions
28
3
⁄
8
”
(72 cm)
10
7
⁄
8
”
(27.6 cm)
or
11
11
⁄
16
”
(29.7 cm)
3
⁄
4
”
1
⁄
2
”
A. Bottom of cabinet cutout
** The spacers need to be installed for this cabinet depth
1.
Complete cabinet preparation following the instructions for
your type of venting. Determine venting cutout locations and
cut out vent openings in the cabinets, walls and/or soffit.
Venting Outside Through the Roof
1.
Measure and mark the lines as the cutout chart shown. Use a
saber saw or keyhole saw to cut an opening through the top
of the cabinet and the roof for the vent.
Cutout chart
Cabinet Height
Hole Shape and Size
12” (30.5 cm)
A 8
17
⁄
64
” wide x 6¼” deep (21 cm x 15.9
cm) rectangular opening in the cabinet top
is required for damper transition clearance.
A
C
D
B*
A. Cutout
B. 8
17
⁄
64
" (21cm) x 6¼” (15.9 cm)
C. 7¾” (19.7 cm) centerline to cabinet front
D. Centerline
Cabinet Height
Hole Shape and Size
15" (38.1 cm)
A 6¼" (15.9 cm) diameter round opening is
required.
A
B*
C
D
A. Cutout
B. Ø 6¼” (15.9 cm)
C. 7
1
⁄
2
” (19 cm) centerline to cabinet front
D. Centerline
2.
Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw