Argus E25 MOD II - Operating Instructions
36
Tighten the socket set screw (4.16)
with a suitable level of torque.
Check whether the electrical signals
from the end-position limit switches
are present and correct. If necessary
repeat the above setting steps until
the signals are correct.
Make sure that all leads are connect-
ed according to the wiring diagram,
and check the connections for possi-
ble short circuits.
Re-install the unit or unit with valve in
the plant.
The torque to tighten the screw or screws
depends on their size.
See the table on Page 20 for the cor-
rect tightening torques.
Changing the timing belt
For work on the unit you need the follow-
ing tools:
Torque wrench to DIN EN ISO 6789
Hexagon keys to
EN ISO 4762/ISO 272
Open-ended spanners to
EN ISO 4762/ISO 272
To change the timing belt, carry out
the work steps as described in the
section “Changing the limit switch
plate” and remove the limit switch
plate.
Place a screwdriver as shown in the
illustration:
Press the screwdriver in the direction
of the arrow to release the tension in
the timing belt.
Содержание 671020
Страница 1: ...Electric Valve Actuator E25 MOD II EN English Translation from German original ...
Страница 9: ...9 Description of the unit ...
Страница 42: ...42 Appendix ATEX Type Approval Examination Certificate ...
Страница 43: ...43 Appendix Certificate of Conformity IECEx ...
Страница 44: ...44 Appendix ISO 9001 Certificate ...
Страница 45: ...Argus E25 MOD II Operating Instructions 45 Notes ...
Страница 46: ...Argus E25 MOD II Operating Instructions 46 ...