Argo ASIAS8DC Скачать руководство пользователя страница 5

EG

5

REMOTE CONTROL UNIT

DISPLAY

Information is displayed when the remote controller is switched on.

If switched off, only the operating mode, the room temperature and

the clock are shown

Operation mode

Fan speed

High speed

Automatic

Medium speed

Low speed

Displayed when

transmitting data 

Set point

temperature

I FEEL mode is active 

(remote controller

sensor active)

Timer modes

Automatic

Cooling
Heating

Dehumidification 
Fan

C

Clock

Room

temperature

Night

mode

Oscillation

Flap

Functions menu

HIGH POWER

mode

TRANSMITTER

When you press the

buttons of the remote

control  unit, the

mark         appears

on  the display to

transmit the setting

changes  to the

receiver  in the air

conditioner.

HOURS AND MINUTES SETTING
BUTTONS

With these buttons is possible to set the

clock and the timer. For details refer to

paragraphs “ SETTING THE HOUR” and

“SETTING THE TIMER”.

TIMER SELECTION BUTTON

Press this button to select the type of timer

to activate. For details refer to paragraph

“SETTING THE TIMER”.

C

TEMPERATURE SETTING BUTTONS

-  (cooler)

Press  this button to decrease the set

temperature.

+ (warmer)

Press  this button to increase the set

temperature.

SENSOR

A

temperature

sensor  inside the

remote control unit

detects  the room

temperature.

CLOK AND TIMER SETTING BUTTON

Press this button in order to:

• set the clock

• set the ON/OFF timer

For details refer to paragraphs “SETTING

THE HOUR” and “SETTING THE TIMER”.

IFEEL/IFEEL C SENSOR SELECTOR

Press this button to modify the active setting

for room temperature detection (from remote

controller to air conditioner and viceversa).

“FAN “ BUTTON (fan speed)

Fan  speed is automatically

selected by the microcomputer.
High speed.
Medium speed.
Low speed.

ON/OFF BUTTON

This button turns the air conditioner ON

and OFF.

FLAP BUTTON

Press this button in order to select the

desired function.

Fixed: six position

Continous oscillations

Automatically oscillations

NIGHT/ECO BUTTON

Press this button in order to select the

NIGHT/ECO mode.

MENU BUTTON

Use this button in order to enter the functions
menu.

“HIGH POWER” BUTTON

Press this button in order to select the HIGH

POWER mode.

MODE SELECTOR BUTTON

Press  this button to modify the air

conditioner mode.

(cooling)

The air conditioner makes the room cooler.

(dry) 

The air conditioner reduces the humidity in

the room.

(automatic)

When this setting is selected, the air

conditioner calculates the difference

between the thermostat setting and the

perceived  room temperature and

automatically switches to the "cool" or

"heat" mode.

(fan)

The  air conditioner works only as a

circulation fan.

Inverter model

MODE SELECTOR BUTTON

Press  this button to modify the air

conditioner mode.

(heating)

The air conditioner makes the room warmer.

Fixed symbol

: the fan stops when the set

temperature is exceeded.

Blinking symbol (HEATING
RECIRCULATION FUNCTION)

: the fan

keeps  running even after the set

temperature is exceeded.

(automatic)

When  this setting is selected, the air

conditioner  calculates the dif ference

between the thermostat setting and the

perceived  room temperature and

automatically switches to the "cool" or "heat"

mode.

Содержание ASIAS8DC

Страница 1: ...RUCCIONES DE USO MANUAL DE INSTRU ES 37 4254 066 00 04 2015 Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partid...

Страница 2: ...NERGY SAVING 11 TROUBLESHOOTING 11 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 15 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will...

Страница 3: ...s in STANDBY it doesn t operate or it is waiting to start The OFF position does not disconnect the power Use the main power switch to turn off power completely OFF LAMPS FUNTION It is possible to set...

Страница 4: ...n NOTE SWITCHES SAFETY INSTRUCTIONS l Read this booklet carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help l This air conditioner i...

Страница 5: ...button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan speed is automatically selected by the microcomputer...

Страница 6: ...h this air conditioner use another heating appliance in conjunction with it Example of operation diagram in the Auto mode with the set room temperature at 23 C NOTE The air conditioner changes the ope...

Страница 7: ...operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating mode an...

Страница 8: ...ton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit t...

Страница 9: ...st the air flow direction using the 4 flaps of the grille frame Chose the best position according to the operation mode and the recommended flap position Press the FLAP button to select the flap funct...

Страница 10: ...ild liquid detergent When cleaning the grille be careful not to force the vanes out of place HOW TO REMOVE THE FILTER EG The air intake grille can be removed in order to wash it with water HOW TO REMO...

Страница 11: ...Shut them to keep the heat or cold out 4 Remove it to ensure good airflow 5 Set the right temperature on the remote control unit 6 Try to use a back up heater 7 Consult your dealer Trouble Clicking so...

Страница 12: ...and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the in...

Страница 13: ...sed Check that the dip switch SW2 for com munication address setting is in the correct position Check that all earth cables are proper ly connected to every terminal Check that the shield of the commu...

Страница 14: ...ical wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Che...

Страница 15: ...ler providing this service Disposing of a battery separately avoids possible negative ef fects on the environment and human health deriving from an inappropriate disposal and enables its components to...

Страница 16: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima com...

Отзывы: