3

EG

NAME OF PARTS AND OPERATION SELECTOR SWITCH

The blinking of TIMER and STANDBY lamps and
OPERATION lamp ON, indicates that: 

1. 

Indoor unit has not been addressed.

2.  Heating mode has been selected, when the system

was in cooling mode, or vice versa. 
Select the correct mode, compatible with the system.

SEE AUTO-DIAGNOSIS TABLE

MULTI SPLIT SYSTEM

only

1. Remote control unit.
2. Remote control sensor:

Detects the room temperature

around the remote control unit, the air conditioner is

controlled accordingly.

3. Air outlet:

Conditioned air is blown out of the air

conditioner through the air outlet.

4. Air intake:

Air from the room is drawn into this section

and passes through air filter which removes dust.

5. Remote control receiver:

This section picks up infrared

signals from the remote control unit (Transmitter).

6. Operation selector (without remote control): 

Push

the button to walk through the operation modes (OFF,

COOL and HEAT)

7. OPERATION lamp:

This lamp lights up during operation.

8. Spia TIMER:

This lamp lights up when the system is

being controlled by the timer.

9. Spia attesa (STANDBY): 

This lamp lights up when the

air conditioner is connected to the power , but it is in

STANDBY (it doesn’t operate or it is waiting to start).

The OFF position does not disconnect the power. Use
the main power switch to turn off power completely.

OFF LAMPS FUNTION

It is possible to set the air conditioner in order to let the

OPERATION, TIMER and STANDBY lamps always OFF,

even during operation.

Be sure that the remote controller is ON (using the ON/OFF

button) and that the symbol           on the display of remote

controller is OFF, then Press contemporary the IFEELand

FAN buttons on the remote control unit for more then 5

seconds.

Repeat the same procedure to set again the normal

operation conditions.

In case of troubleshooting the air conditioner diagnostic

system activates the lamps accordingly, even if they are

set to OFF. See paragraph TROUBLESHOOTING for further

details.

If the air conditioner is powered, but the lamps are off, try

to activate them using this procedure.

10.Air intake latch, on two sides.
11.Air filter.
12.Suspension brackets.
13.Refrigerant couplings.
14.Condensate drain connection.
15.Sensor:

Detects the room temperature around the unit.

NOTA

When the unit receives a signal from the remote
controller, all the three lamps (OPERATION, TIMER and
STANDBY) light up for a moment to indicate the correct
signal reception.

2

1

3

12

14

5

13

5

7

8 9

OPER TIMER STBY

5

6

7

8

9

15

6

10

11

4

MODELS

ASIAS8 - ASIBS9

MODELS

ASICS10 - ASIDS13

WARNING

Содержание ASIAS8DC

Страница 1: ...RUCCIONES DE USO MANUAL DE INSTRU ES 37 4254 066 00 04 2015 Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partid...

Страница 2: ...NERGY SAVING 11 TROUBLESHOOTING 11 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 15 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will...

Страница 3: ...s in STANDBY it doesn t operate or it is waiting to start The OFF position does not disconnect the power Use the main power switch to turn off power completely OFF LAMPS FUNTION It is possible to set...

Страница 4: ...n NOTE SWITCHES SAFETY INSTRUCTIONS l Read this booklet carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help l This air conditioner i...

Страница 5: ...button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan speed is automatically selected by the microcomputer...

Страница 6: ...h this air conditioner use another heating appliance in conjunction with it Example of operation diagram in the Auto mode with the set room temperature at 23 C NOTE The air conditioner changes the ope...

Страница 7: ...operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating mode an...

Страница 8: ...ton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit t...

Страница 9: ...st the air flow direction using the 4 flaps of the grille frame Chose the best position according to the operation mode and the recommended flap position Press the FLAP button to select the flap funct...

Страница 10: ...ild liquid detergent When cleaning the grille be careful not to force the vanes out of place HOW TO REMOVE THE FILTER EG The air intake grille can be removed in order to wash it with water HOW TO REMO...

Страница 11: ...Shut them to keep the heat or cold out 4 Remove it to ensure good airflow 5 Set the right temperature on the remote control unit 6 Try to use a back up heater 7 Consult your dealer Trouble Clicking so...

Страница 12: ...and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the in...

Страница 13: ...sed Check that the dip switch SW2 for com munication address setting is in the correct position Check that all earth cables are proper ly connected to every terminal Check that the shield of the commu...

Страница 14: ...ical wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Che...

Страница 15: ...ler providing this service Disposing of a battery separately avoids possible negative ef fects on the environment and human health deriving from an inappropriate disposal and enables its components to...

Страница 16: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima com...

Отзывы: