4

HOW TO INSTALL BATTERIES

l

Remove trhe lid in the rear part of the remote control unit

and check the settings of the four microswitches as

shown below:

TEMPERATURE SENSOR SELECTOR 

l

Under normal conditions the room temperature is detected

and checked by the temperature sensor placed in the

remote controller (I FEEL icon displayed ).This function

is designed to provide a comfortable room temperature

by transmitting the temperature control command from the

location next to you. When using this function, the remote,

control should always be pointed at the air conditioner ,

therefore it should be placed in a position in which it is

visible by the indoor unit (for example, do not put it in a

drawer).

l

It is possible to disable the remote controller room sensor

pressing the I FEEL button. In this case the I FEEL icon

on the remote controller display lights of f and only the

sensor placed in the air conditioner becomes active.

USING THE REMOTE CONTROL UNIT

l

Insert two AAA alkaline batteries of 1,5 V -DC making

sure that point in the direction marked in the battery

compartment.The displayed time flashes.

Press the SEL TYPE button.

Remote controller is now ready for operation. 

l

The batteries last average more than six months, anyway

it depends on how much you use the remote control

unit.

Remove the batteries if you do not use the remote control

unit for more than one month.

Replace the batteries when  the remote control unit lamp

fails to light, or when the air conditioner does not receive

the remote control unit signals.

l

The batteries of the remote control contain polluted

substances. Exhausted batteries must be disposed

according to the laws in force.

OPERATION WITH THE REMOTE CONTROL UNIT

When using the remote control unit, always point the unit

transmitter head directly at the air conditioner receiver.

HOW TO TURN ON THE AIR CONDITIONER

Press the ON/OFF button to turn the air conditioner on.

The OPERATION lamp will light up, indicating the unit is in

operation.

The remote control unit transmits signals to the indoor
unit each time you press a key and at any temperature
change detected by the IFEEL sensor. In case of
troubles (low batteries, remote control placed in a
position not visible by the indoor unit,...) room
temperature control  is automatically switched to the
sensor of the indoor unit. In this case, the temperature
around the remote control unit may differ from the
temperature detected in the air conditioner position.

NOTE

SWITCHES

SAFETY INSTRUCTIONS

l

Read this booklet carefully before using this air
conditioner. If you still have any difficulties or
problems, consult your dealer for help.

l

This air conditioner is designed to give you
comfortable room conditions. Use this only for its
intended purpose as described in this Instruction
Manual.

l

Never use or store gasoline or other flammable vapor or

liquid near the air conditioner. It is very dangerous.

l

Never install electrical equipment, which is not
protected with IPX1 protection (protection against
vertical water drop), under the unit.

l

The manufacturer assumes no responsabilities if the

safety regulations or local codes are not observed.

l

Never use the power main switch to start or stop the
air conditioner: always use the ON/OFF button on the
remote control unit or the selector switch on the unit.

l

Do not let children play with the air conditioner.

l

Do not cool the room too much if babies or invalids
are present.

l

This air conditioner is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the air conditioner
by a person responsible for their safety.

WARNING

CAUTION

INSTALLATION LOCATION

l

We recommend this air conditioner to be installed

properly by qualified installation technicians in

accordance with the installation instructions provided

with the unit.

l

Do not install this air conditioner where there are

fumes or flammable gases, or in an extremely humid

space such as a green house.

l

Do not install the air conditioner where excessively

high heat-generating objects are placed.

l

Do not install the air conditioner where the

atmosphere is extremely damp or humid (e.g.

greenhouse or laundry) it could be wetted by drops

of water (i.e. in laundries).

WARNING

ELETRICAL REQUIREMENTS

l

Before installation, check that the voltage of the electric

supply in your home or office is the same as the voltage

shown on the nameplate.

l

All wiring must conform to the local electrical codes.

Consult your dealer or a qualified electrician for details.

l

Each unit must be properly grounded with a ground (or

earth) wire or through the supply wiring.

l

Wiring must be done by a qualified electrician.

NOTE

IF YOU INSTALL MORE THAN ONE INDOOR
UNIT IN THE SAME ROOM:

It is possible to utilise only one remote control for all
the units.
On the contrary, if you want to address each remote
control to its unit, follow the procedure”Remote control
unit/indoor unit address” (see Installation Instructions).

PLEASE, SEE THE END
OF THIS MANUAL FOR
DETAILS

Содержание ASIAS8DC

Страница 1: ...RUCCIONES DE USO MANUAL DE INSTRU ES 37 4254 066 00 04 2015 Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partid...

Страница 2: ...NERGY SAVING 11 TROUBLESHOOTING 11 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 15 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will...

Страница 3: ...s in STANDBY it doesn t operate or it is waiting to start The OFF position does not disconnect the power Use the main power switch to turn off power completely OFF LAMPS FUNTION It is possible to set...

Страница 4: ...n NOTE SWITCHES SAFETY INSTRUCTIONS l Read this booklet carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help l This air conditioner i...

Страница 5: ...button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan speed is automatically selected by the microcomputer...

Страница 6: ...h this air conditioner use another heating appliance in conjunction with it Example of operation diagram in the Auto mode with the set room temperature at 23 C NOTE The air conditioner changes the ope...

Страница 7: ...operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating mode an...

Страница 8: ...ton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit t...

Страница 9: ...st the air flow direction using the 4 flaps of the grille frame Chose the best position according to the operation mode and the recommended flap position Press the FLAP button to select the flap funct...

Страница 10: ...ild liquid detergent When cleaning the grille be careful not to force the vanes out of place HOW TO REMOVE THE FILTER EG The air intake grille can be removed in order to wash it with water HOW TO REMO...

Страница 11: ...Shut them to keep the heat or cold out 4 Remove it to ensure good airflow 5 Set the right temperature on the remote control unit 6 Try to use a back up heater 7 Consult your dealer Trouble Clicking so...

Страница 12: ...and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the in...

Страница 13: ...sed Check that the dip switch SW2 for com munication address setting is in the correct position Check that all earth cables are proper ly connected to every terminal Check that the shield of the commu...

Страница 14: ...ical wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Che...

Страница 15: ...ler providing this service Disposing of a battery separately avoids possible negative ef fects on the environment and human health deriving from an inappropriate disposal and enables its components to...

Страница 16: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima com...

Отзывы: