Argo ASIAS8DC Скачать руководство пользователя страница 11

11

TIPS FOR ENERGY SAVING

DO NOT:

l

Block the air intake and outlet of the unit. 

If they are obstructed, the unit will not work well, and

may be damaged.

l

Let direct sunlight into the room. Use sunshades, 

blind or curtain.

DO:

l

Always try to keep the air filter clean.  A clogged filter 

will impair the performance of the unit.

l

To prevent conditioned air from escaping, keep windows,

doors and any other openings closed.

TROUBLESHOOTING

WARNING

l

The use of portable telephones near the air conditioner

may cause disturbance to its normal operation and must 

be avoided. In case abnormal operation is noticed,

(OPERATION lamp lights, but the air conditioner will not

run) to restore normal operation turn-off electric supply

for about 3 minutes, by disconnecting the main switch or

the wall plug, then start again the air conditioner.

If your air conditioner does not work properly , first check

the following points before requesting service.

If it still does not work properly, contact your dealer or service

centre.

Trouble:

the air conditioner does not run at all.

Possible cause:

1. Power failure.

2. Leakage breaker tripped.

3. Operation button is OFF.

4. Batteries in remote control unit have run down.

Remedy:

1. Restore power.

2. Contact service centre.

3. Press the button again.

4. Replace batteries.

Trouble:

Poor cooling or heating performance.

Possible cause:

1. Dirty or clogged air filters.

2. Heat source or many people in room.

3. Doors and/or windows are open.

4. Obstacle near air intake or air discharge port.

5. The set temperature on the remote control unit is too

high.

6. Outdoor temperature is too low (heat pump version).

7. Defrosting system does not work (heat pump version).

Remedy:

1. Clean air filters to improve airflow.

2. Eliminate heat source if possible.

3. Shut them to keep the heat or cold out.

4. Remove it to ensure good airflow.

5. Set the right temperature on the remote control unit.

6. Try to use a back-up heater.

7. Consult your dealer.

Trouble:

Clicking sound is heard from the air conditioner.

Possible cause:

1. During operation, any plastic parts may expand or shrink

due to a sudden temperature change. In this event, a

clicking sound may occur.

Remedy:

1. This is normal, and the sound will disappear when an

even temperature is settled.

EG

CONDENSATE

DRAIN PAN

The inspection or replacement of internal components

involve the removal of the condensate drain pan.

Some metal edges and the vanes of heat exchanger are

sharp and may cause injury if handled improperly; be

especially careful when you clean these parts.

CAUTION

HOW TO REMOVE THE CONDENSATE DRAIN PAN

RUBBER CORK

CONNECTORS

CLIPS (2)

S U P P O R T

PLATE (2)

SCREW (4)

SPECIAL SCREW (4)

1.

Open the air intake grille.

2.

Drain the condensate water into a bucket  trough the

rubber cork that should be soon closed.

3.

Remove the frame-grille assembly by loosening the four

special screws with washer; you can utilise the two clips

that fix the frame to the unit.

4.

Disconnect the electrical connectors between the frame-

grille assembly and the unit.

5.

Remove the four screws of the two support plates.

6.

Grasp the two support plates, remove with care the

condensate drain pan and clean it inside, if necessary .

7.

Once finished the maintenance, reassemble the pan,

aligning the side with the hole for condensate drain and

the side with the pump; insert the connectors of the unit

into the proper hole in the pan.

8.

Fix again the four screws of the support plates and the

frame group aligning the corner from which the wires exit

and the corner with the connectors of the unit.

9.

Mount the air intake grille along with the filter; be sure

that the safety string has been attached and that the latch

screw has been fixed on both sides.

ADDITIONAL MAINTENANCE

Содержание ASIAS8DC

Страница 1: ...RUCCIONES DE USO MANUAL DE INSTRU ES 37 4254 066 00 04 2015 Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partid...

Страница 2: ...NERGY SAVING 11 TROUBLESHOOTING 11 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 15 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will...

Страница 3: ...s in STANDBY it doesn t operate or it is waiting to start The OFF position does not disconnect the power Use the main power switch to turn off power completely OFF LAMPS FUNTION It is possible to set...

Страница 4: ...n NOTE SWITCHES SAFETY INSTRUCTIONS l Read this booklet carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help l This air conditioner i...

Страница 5: ...button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan speed is automatically selected by the microcomputer...

Страница 6: ...h this air conditioner use another heating appliance in conjunction with it Example of operation diagram in the Auto mode with the set room temperature at 23 C NOTE The air conditioner changes the ope...

Страница 7: ...operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating mode an...

Страница 8: ...ton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit t...

Страница 9: ...st the air flow direction using the 4 flaps of the grille frame Chose the best position according to the operation mode and the recommended flap position Press the FLAP button to select the flap funct...

Страница 10: ...ild liquid detergent When cleaning the grille be careful not to force the vanes out of place HOW TO REMOVE THE FILTER EG The air intake grille can be removed in order to wash it with water HOW TO REMO...

Страница 11: ...Shut them to keep the heat or cold out 4 Remove it to ensure good airflow 5 Set the right temperature on the remote control unit 6 Try to use a back up heater 7 Consult your dealer Trouble Clicking so...

Страница 12: ...and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the in...

Страница 13: ...sed Check that the dip switch SW2 for com munication address setting is in the correct position Check that all earth cables are proper ly connected to every terminal Check that the shield of the commu...

Страница 14: ...ical wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Che...

Страница 15: ...ler providing this service Disposing of a battery separately avoids possible negative ef fects on the environment and human health deriving from an inappropriate disposal and enables its components to...

Страница 16: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima com...