![Argo ADG ECO PLUS 100PH Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/argo/adg-eco-plus-100ph/adg-eco-plus-100ph_installation-manual_2967431045.webp)
Duct Type Unit
41
WARNING!
(1) Before working, please check whether the indoor and outdoor units are
powered on.
(2) Match the terminal numbers and wire colors with the colors indicated in the
indoor unit.
(3) Wrong wire connection may burn the electrical components.
(4) Connect the wires firmly to the wiring box. Incomplete installation may lead to
fire hazard.
(5) Please use wire clamps to secure the external covers of connecting wires.
(Insulators must be clamped securely; otherwise, electric leakage may occur.)
(6) Ground wire should be connected.
(4) Wire between indoor and outdoor units.
Single-phase unit:
AEG ECO PLUS 35PIH, AEG ECO PLUS 50PIH
.
ADG ECO PLUS 35PH+AEG ECO PLUS 35PIH
ADG ECO PLUS 50PH+AEG ECO PLUS 50PIH
①
.
Power cords 3×1.5mm
2
②
.
Power cords 4×1.0mm
2
③
.
Communication cords 2×0.75mm
2