Subject to change · Filter and recirculating pump unit UMPC 045 Light Line· 0119 · EN
Page 37
www.argo-hytos.com
NOTE
Variable viscose behavior
›
Viscosities of a medium are always temperature-dependent.
17.3
Operating conditions
CAUTION
Risk of burns
Contact temperatures according to DIN EN563 (3) and DIN EN13202 (4) may be exceeded during
operation.
›
Allow the filter unit to cool down before touching it.
Electric drive 1 ~ 230 V 50/60 Hz
mm
2
/s (min. continuous operation)
mm
2
/s (max. continuous operation)
15
600
(An exact determination of the cleanliness class is
possible in a viscosity range of 15 mm
2
/s to 250 mm
2
/s.)
Electric drive 3 ~ 400 V 50/60 Hz
mm
2
/s (min. continuous operation)
mm
2
/s (max. continuous operation)
15
600
(An exact determination of the cleanliness class is
possible in a viscosity range of 15 mm
2
/s to 250 mm
2
/s.)
Permissible temperature range
Hydraulic fluid °C
Surroundings °C
10 ... 65
0 ... 50
Permissible suction heights
m (max.) first use
m (max.) operating condition
2
6
Media resistance
Hydraulic fluids based on mineral oil, rapeseed oils and
synthetic esters.
Mains fuses
230 V, 50/60 Hz, 16 A
400/460 V, 50/60 Hz, 16 A
Working position
standing
17.4
Hydraulic circuit diagram
Fig. 23: Hydraulic diagram
Table10: Operating conditions