Subject to change · Filter and recirculating pump unit UMPC 045 Light Line · 0119 · EN
Page 36
www.argo-hytos.com
17.2
Technical data
Nominal flow
l/min (50 Hz)
l/min (60 Hz)
45
54
Pressure relief valve
bar
6 ± 0.5
Pressure holding valve
bar
2.5 ± 0.5
Max. operating pressure
bar
7
Filter element
V7.1560-103 ß3(c)
≥ 200
V7.1560-03 ß5(c)
≥ 200
V7.1560-06 ß10(c)
≥ 200
Clogging indicator
Optical clogging indicator DG 042-01
p = 2.0 ± 0.3 bar
Suction side
Connection G 1 ¼" with hose DN 32 and suction lance
(when replacing the suction hose only use a spiral hose)
Pressure side
Connection G1"with hose DN 25 and pressure lance
Suction strainer
Screen element 280 μm
Electric drive
1-Phase alternating current motor
230 V; 50/60 Hz; 1.1 kW; n = 1,500/1,800 min
-
¹; Size 90
3-Phase AC motor
400 / 460 V; 50 / 60 Hz; 1.1 kW; n = 1,500 / 1,800 min
-1
; Size 90
Weight
kg
approx. 88
Sound power level
db(A) max.
max. 73 (Under operating conditions permissible for continuous operation)
max. 78 (Under operating conditions permissible for short-term operation)
Dimensions
l x w x h
786 x 564 x 1,045
Table 9: Technical data