background image

Subject to change · Filter and recirculating pump unit UMPC 045 Light Line · 0119 · EN

Page 11

www.argo-hytos.com

Housing cover

The housing cover closes the filter housing and serves, inter alia, for venting.

Filter housing with filter element

The filter housing contains the replaceable filter elements.
Changing the filter elements is described in "11.2 Changing the filter element" on page 25.

Pump / electric motor

The pump unit driven by an electric motor is responsible for media conveyance.

OPCom screen protective filters 

The filter unit is provided with screen filters. These elements protect the OPCom partilce sensor from dirt which can block the oil 
flow. Screen filters should be cleaned regularly. 

Suction strainer

The filter unit is provided with a protective strainer at the suction side, which has to be serviced regularly.
A missing protective strainer may lead to destruction of the pump. Checking / changing the suction filter is described in "11.4 
Checking / changing the suction filter element (pump protection filter)" on page 27.

Fig.2: Component overview 2

Filter housing 
with filter element

Housing cover

Suction strainer

Pump drive /
electric motor

Pump

OPCom screen 
protective filters 

Содержание UMPC 045 Light Series

Страница 1: ...tures The information given does not release the user from his her own assessments and inspection Our products are subject to a natural wear and aging process All rights are reserved by ARGO HYTOS eve...

Страница 2: ...2 7 Product and technology related safety instructions 7 3 General instructions 8 4 Scope of delivery 9 5 About this product 10 5 1 Component overview 10 5 2 Controls 13 5 3 Identification of the prod...

Страница 3: ...1 4 Checking changing the suction filter element pump protection filter 27 11 4 1 Removing the suction filter 27 11 4 2 Installing the suction filter 27 11 5 Checking cleaning OPCom protective filters...

Страница 4: ...quickly and safely with your product we use standardized safety instructions symbols terms and abbreviations For better understanding these are explained in the following sections 1 3 1 Safety instru...

Страница 5: ...symbols Symbols Meaning If this information is not observed the product cannot optimally be used or operated Singular independent action step instruction 1 2 3 Numbered instruction The numbers indica...

Страница 6: ...than the intended use described is improper and inadmissible If unsuitable products are installed or used in safety related applications unintended operating states may occur in the application which...

Страница 7: ...hich can cause personal injury and or material damage Therefore only use the product in safety relevant applications if this use is explicitly specified and permitted in the product documentation You...

Страница 8: ...c lines leading to premature wear or malfunction Make sure that connections hydraulic lines and attachment parts e g gauges are free from dirt and chips Prior to commissioning check that all hydraulic...

Страница 9: ...hange Filter and recirculating pump unit UMPC 045 Light Line 0119 EN Page 9 www argo hytos com 4 Scope of delivery This package includes 1 Filter and Recirculating Pump Unit UMPC 045 Light Line 1 Oper...

Страница 10: ...he particle monitor OPCom allows a particle measurement according to the latest standard Thus the level of contamination as well as the trend of the cleanliness of fluids can be observed Hose holder O...

Страница 11: ...creen protective filters The filter unit is provided with screen filters These elements protect the OPCom partilce sensor from dirt which can block the oil flow Screen filters should be cleaned regula...

Страница 12: ...ential pressure indicator This switch monitors the pressure of the medium before and after the filter When the preset differential pressure is reached the optical indicator changes from green to red I...

Страница 13: ...ally stores up to 3 000 results When the memory capacity has been reached the last measured value is stored and the oldest measured value is overwritten For more detailed information read the suppleme...

Страница 14: ...C 045 Light Line 0119 EN Page 14 www argo hytos com 5 3 Identification of the product Serial number Type Manufacturing date encrypted Filter element type Fineness of the filter Nominal volume flow Max...

Страница 15: ...a confined space to protect it from humidity and condensation Fig 7 Transport rack The unit is mounted on a transport rack with two wheels This hand truck enables the unit to be transported without d...

Страница 16: ...pecified on the type plate of the motor the power source has appropriately been secured 16 A the cross section is of sufficient size cable and connection to the power source are in perfect condition T...

Страница 17: ...failure In order to prevent unintentional starting of the unit always switch off and unplug the unit 8 3 Venting To bleed the unit automatically loosen the black cap 3 on the ventilating valve 1 NOTE...

Страница 18: ...r manual In the front panel of the UMPC 045 Light Line unit there is a serial interface fig 5 page 13 via which the OPCom Particle Monitor can be read out and configured For this purpose a PC and an a...

Страница 19: ...tion strainer on the suction side which must be serviced regularly A missing protective strainer can lead to the destruction of the pump Order No see spare part list The manufacturer does not accept l...

Страница 20: ...ving reached the desired fill level 8 After completion of the operation pull the suction lance suction tube out of the container barrel and suck air for max 30 seconds Thus the residual oil from the f...

Страница 21: ...tion 9 Switch off the filter unit at the circuit breaker 10 Fix the suction lance suction pipe and the discharge pipe to the corresponding brackets at the filter unit NOTE Achieving the maximum cleani...

Страница 22: ...barrel 4 Move the lever to the Pumping position Fig 11 Lever pumping filtering 5 Switch on the filter unit at the on off switch 6 Check the oil flow observe sufficient immersion depth of the suction l...

Страница 23: ...d ventilation of the system 7 Check the oil flow for a possible insufficient insertion depth of the suction pipe in the oil tank 8 Monitor the filling level at the machine or system and switch off the...

Страница 24: ...FTER filter Particle Counting Cleaning BEFORE filter Fig 15 Three way valve 6 Switch on the filter unit at the on off switch circuit breaker and let it operate for approx 5 min Initialization of the p...

Страница 25: ...er to life Risk of electric shock During repair work turn off the unit and pull the mains plug NOTE Impaired function by dirt ingress into the pump The function of the filter unit is no longer guarant...

Страница 26: ...ilter element from the cover 1 Push the filter element at the cover in arrow direction 1 and remove it in arrow direction 2 2 Dispose of the filter element according to the national environmental legi...

Страница 27: ...ing the suction filter element pump protection filter 11 4 1 Removing the suction filter Fig 20 Removing the suction filter 1 2 3 4 11 4 2 Installing the suction filter 1 Always replace the sealing ri...

Страница 28: ...ecking cleaning OPCom protective filters 1 Provide a drip tray for residual oil and the contaminated filter element 2 Unscrew both filters 1 2 3 Clean filters using cleaning agent and compressed air I...

Страница 29: ...pump unit UMPC 045 Light Line 0119 EN Page 29 www argo hytos com 12 Decommissioning The filter unit UMPC 045 is a component which does not have to be taken out of service Therefore the chapter in thi...

Страница 30: ...Subject to change Filter and recirculating pump unit UMPC 045 Light Line 0119 EN Page 30 www argo hytos com 13 Disassembly This chapter does not contain any information for your device...

Страница 31: ...protection Careless disposal of the filter unit UMPC 045 and the pressurized fluid can lead to environmental pollution Therefore dispose of the filter unit and the pressure fluid according to the nati...

Страница 32: ...er unit NOTE The warranty of ARGO HYTOS applies to the delivered configuration and extensions which were taken into account during configuration The warranty expires after a conversion or extension th...

Страница 33: ...to the overall system in which the particle monitor OPCom Portable is installed Have the operating conditions or the area of application of the particle monitor OPCom Portable been changed Have modif...

Страница 34: ...rt capacity of the filter element is reached Leakage at the suction hose falsification of the measurement results by free air in the oil air bubbles Rotary valve on lever position Pumping Replace filt...

Страница 35: ...Subject to change Filter and recirculating pump unit UMPC 045 Light Line 0119 EN Page 35 www argo hytos com Fig 22 Dimension drawing 17 Technical specifications 17 1 Dimension drawing...

Страница 36: ...Connection G 1 with hose DN 32 and suction lance when replacing the suction hose only use a spiral hose Pressure side Connection G1 with hose DN 25 and pressure lance Suction strainer Screen element 2...

Страница 37: ...termination of the cleanliness class is possible in a viscosity range of 15 mm2 s to 250 mm2 s Electric drive 3 400 V 50 60 Hz mm2 s min continuous operation mm2 s max continuous operation 15 600 An e...

Страница 38: ...eries Mobile filter unit UMPC 045 Ligh line to which this declaration pertains are in conformity with the following directives Directive 2006 42 EC Machinery Directive Directive 2014 30 UE EMC Directi...

Страница 39: ...awing 2 4 Housing 5 Filter element 2 Cover complete 3 O ring 1 Equipment rack 6 Hose 7 Fixture 8 Flat head screw 9 Motor 10 Pump not shown 11 Wheel 12 Cap 23 Hose clamp 17 Screen filter 16 Valve compl...

Страница 40: ...Filter and recirculating pump unit UMPC 045 Light Line 0119 EN Page 40 www argo hytos com Fig 26 Spare parts drawing 3 27 Ball valve 26 OPCom particle monitor 28 Power supply complete not shown 29 Pre...

Страница 41: ...l cap 2 UM 045 0711 13 Pressure hose 1 UM 045 0750 o Z DN 25 2 5 meters 14 Pipe 1 UM 045 0756 0 4 meter 15 Hose clamp 2 13797700 GBS 32 35mm W1 16 Valve complete 1 41247400 17 Screen filter 2 15077600...

Страница 42: ...public ARGO HYTOS s r o info cz argo hytos com ARGO HYTOS Protech s r o info protech argo hytos com France ARGO HYTOS SARL info fr argo hytos com Germany ARGO HYTOS GMBH info de argo hytos com Great B...