A defective control solenoid coil may only be replaced with the manufacturer‘s original replacement coil with identical parameters.
› Switch off the pressure source (pump) of the hydraulic circuit (see also 7.5).
› Switch off the pressure source (pump) of the hydraulic circuit (see also 7.5).
› Relieve the hydraulic circuit including the accumulators by connecting it to the tank (see also 7.5).
› Make sure that the hydraulic circuit is de-pressurized (see also 7.5).
› Switch off the electrical supply to the valve solenoids (see also 7.5)..
› Ensure that the surface of the valve and solenoid coils is cooled to a low enough temperature to prevent skin burns (see also 7.5).
› Clean the surface and surroundings of the valve.
› Disconnect the coil surface ground wire.
› Disconnect the coil cable from the power supply.
› Loosen the coil fastening nut by turning it anti-clockwise using the wrench a = 36. Remove the nut.
› Remove the sealing ring (1) 21.89x2.62, the coil and the second sealing ring 22x1.5 from the control system tube.
› Check the surface condition of the control system for damage, e.g. corrosion.
› Connect the power supply cable to the new coil according to point 7.2.1, unless a coil with an already connected cable has been supplied by the
manufacturer. We recommend using a new cable to connect the new coil. Replace the sealing rings with new ones. They are supplied in a set with
the coil and a new fastening nut.
› Replace the coil sealing rings with new ones. They are supplied in a set with the coil and a new clamping nut.
› Fit a new 22x1.5 sealing ring, a new coil with attached cable, a new 21.89 x 2.62 sealing ring and screw on a new clamping nut on the control
system tube. Tighten the nut with a wrench to a torque of 5 + 1 Nm.
› Connect the ground wire to the new coil.
› After completing the coil replacement, check the valve for proper operation.
Hydraulic block
Control system
Coil
Mounting nut
Sealing ring (1)
21.89x2.62
Sealing ring (2)
22x1.5
During normal operation, keep the valve clean and free of dust deposits on the surface. Deposits both impair cooling of the valve and coils and can
form flammable layers prone to ignition. Depending on the conditions of use, check the hydraulic circuit for leaks, the electrical parts including cables
for damage and the valve for correct function at appropriate intervals. The check should be performed every time the device is started, but at least
once a week during long-term operation.
7.7 Product maintenance
7.6.3 Replacing the coil
Ordered as spare sparts, see catalog SP 8010.
Item
Description of spare part
Designation
Order number
1
Valve coil
See coil overview
See coil overview*
2
Sealing ring OS - coil
O-ring 22x1.5 VMQ 50 (silicon)
in set with coil
3
Seal under the nut
O-ring 21.89x2.62 VMQ 70 (silicon)
in set with coil
4
Coil mounting nut
in set with coil
5
Terminal lid seal
O-ring 46x2 VMQ (silicon)
34950700
6
Fastening nut with emergency control M7
33050700
*All coils are supplied complete with mounting nut (4) and sealing rings (2 and 3).
7.8 Spare parts supplied
1
2
5
4
3
1
6
Содержание SD1EX-A2
Страница 2: ...Subject to change_SD1EX A2 A3 _14088_1en_05 2022 Page 2 www argo hytos com Declaration of conformity...
Страница 3: ...Subject to change_SD1EX A2 A3 _14088_1en_05 2022 Page 3 www argo hytos com...
Страница 4: ...Subject to change_SD1EX A2 A3 _14088_1en_05 2022 Page 4 www argo hytos com...
Страница 23: ...N vod k pou it _SD1EX A2 A3 _14088_1cz_05 2022 Strana 2 www argo hytos com Prohl en o shod...
Страница 24: ...N vod k pou it _SD1EX A2 A3 _14088_1cz_05 2022 Strana 3 www argo hytos com...
Страница 25: ...N vod k pou it _SD1EX A2 A3 _14088_1cz_05 2022 Strana 4 www argo hytos com...