![Argo-Hytos SD1EX-A2 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/argo-hytos/sd1ex-a2/sd1ex-a2_operating-instructions-manual_2967781012.webp)
Subject to change_SD1EX-A2(A3)_14088_1en_05/2022
Page 12
www.argo-hytos.com
An overview of possible valve modifications is described in the ordering code.
The number of spool positions, the spool connection and the type of emergency control and the electrical parameters of the coil cannot be
subsequently changed by the user.In the case of a valve with a 10 W coil, the coil surface temperature and the application for the temperature class
can be affected by adjusting the ambient temperature (see 4.4Ambient temperature range for each class).
The coils with AC power supply and built-in rectifier are supplied with only the cable attached, with optional lengths of 3 and 8 m as standard.
5. Product modification
Ordering code
Ax
H
SD1EX - / /
-
x
xxx
Ax
xx
B
xxxxx
x
1
2
3
4
5
6
7
8
9
10
1
Screw-in spool type, solenoid operated directional control valve, designed for potentially explosive atmospheres
Threaded screw-in chamber type 3/4-16 UNF
A2
cavity A2 (C-8-2)
A3
cavity A3 (C-8-3)
High performance-
Valve connection ( see connection table)
Spool connection (according to connection table)
DC voltage
01200
12 V DC / 0,75 A
02400
24 V DC / 0,39 A
04800
48 V DC / 0,19 A
11000
110 V DC / 0,094 A
AC voltage 50/60 Hz
11050
110 V AC / 0,112 A
23050
230 V AC / 0,052 A
Temperature class - coil nominal input power
A4
coil supply power 10 W, temperature class T4
A6
coil supply power 10 W, temperature class T5, T6
Cable length
without designation
(only DC version)
without cable
3
(versions AC and DC)
3 m
8
(versions AC and DC)
8 m
Manual override
without designation
standard
M7
detent assembly
Seals
without designation
NBR
Surface treatment - zinc coated (ZnNi)
B
520 h in NSS according to ISO 9227
Valve certification
without designation
ATEX, IECEx
A
IECEx for Australia and New Zealand
E
EAC for EAEU states*
*EAEU= Eurasian Economic Union, certificate
according to TR TS 012/2011 valid for the Russian
Federation, Belarus, Armenia, Kazakhstan and
Kyrgyzstan.
11
2
3
7
4
6
8
10
5
11
9
Valve connection table
SD1E-A2
SD1E-A3
S55
2S6
2S7
1
2
2
3 1
1
2
Содержание SD1EX-A2
Страница 2: ...Subject to change_SD1EX A2 A3 _14088_1en_05 2022 Page 2 www argo hytos com Declaration of conformity...
Страница 3: ...Subject to change_SD1EX A2 A3 _14088_1en_05 2022 Page 3 www argo hytos com...
Страница 4: ...Subject to change_SD1EX A2 A3 _14088_1en_05 2022 Page 4 www argo hytos com...
Страница 23: ...N vod k pou it _SD1EX A2 A3 _14088_1cz_05 2022 Strana 2 www argo hytos com Prohl en o shod...
Страница 24: ...N vod k pou it _SD1EX A2 A3 _14088_1cz_05 2022 Strana 3 www argo hytos com...
Страница 25: ...N vod k pou it _SD1EX A2 A3 _14088_1cz_05 2022 Strana 4 www argo hytos com...