The valves are available

 in three surface temperature classes:

T4

 with a maximum surface temperature of 135 °C

T5

 with a maximum surface temperature of 100 °C

T6

 with a maximum surface temperature of 85 °C

The use of the valve in the temperature class is subject to the maximum supply voltage of the coil not being exceeded, the working 
fluid temperature not being exceeded and the ambient temperature not being exceeded 

(see Table 4.4 Basic technical parameters)

2. Valve protection against initiation of explosion of explosive atmosphere 

2.1 Protection of electrical parts

The electrical part of the valve is an ATEX and IECEx certified solenoid coil. 
The basic type of protection is to pot the coil with potting compound „m“ (EN 60079-18, IEC 60079-18). For a DC-powered coil, protection is 
combined by potting the coil with „m“ using a terminal block with „e“ certification (EN 60079-7, IEC 60079-7).  
In addition, a fixed „t“ closure is used for dust (EN 60079-31, IEC 60079-31).

EPS14ATEX1744 X

IECEx EPS14.0064 X

AC

      l M2 Ex mb I Mb

Ex mb I Mb

      lI 2G Ex mb IIC T4, T5, T6 Gb

Ex mb IIC T4, T5, T6 Gb

      lI 2D Ex mb IIIC T135°C, T100°C, T85°C Db

Ex mb IIIC T135°C, T100°C, T85°C Db

DC

      l M2 Ex eb mb I Mb

Ex eb mb I Mb

      lI 2G Ex eb mb IIC T4, T5, T6 Gb

Ex eb mb IIC T4, T5, T6 Gb

      lI 2D Ex tb IIIC T135°C, T100°C, T85°C Db

Ex tb IIIC T135°C, T100°C, T85°C Db

2.2 Cable grommet

The cable grommet is a separately certified component with ATEX and IECEx certification:

 

I M2 Ex eb I Mb

 

II 2G Ex eb IIC Gb

 

II 2D Ex tb IIIC Db

2.3 Protection of non-electrical parts

The non-electrical part of the valve consists of the hydraulic part and the solenoid control system.
The safety of the non-electrical parts has been ensured and assessed according to ISO 80079-36 and ISO 80079-37 and 

EN ISO/IEC 80079-38.

 › The moving parts, the spool/cone, armature and pin of the control system, perform a sliding motion in a space separated by a seal from the  

 

  surround ing environment and flooded with working fluid.

 › Not exceeding the maximum surface temperature of the given temperature class is conditioned by not exceeding the maximum temperature 

  of the working fluid (70 °C), the maximum ambient temperature (see table 4.4 Basic technical parameters) and the nominal voltage of the coil.

 › The valve body and spool body are of robust construction, sufficiently resistant to destruction by mechanical shock. 

 

 

 

  (Valve body impact resistance test performed according to EN IEC 60079-0 paragraph 26.4.2: two impacts with a weight with a hardened head of  

  diameter D25 mm, weighing m = 1 kg, falling from a height of 0.7 m, with a total potential energy of 7 J)

 › The hydraulic section has sufficient compressive strength, tested at 1.5 times the maximum operating pressure of the fluid.
 › The construction materials used meet the requirements for limited content of certain elements to prevent the formation of electrical cells and  

 

  excessive corrosion.

 › The surface materials used do not produce sparks during mechanical impacts.
 › The sliding rod of the manual emergency control N7 of the pilot valve is protected by a sealing sleeve against the ingress of contaminating  

 

  particles, especially hard particles, which could create an initiating spark.

2.4 Applicable legislation and standards

The valve complies with the relevant requirements of legislation and standards:

Directive 2014/34/EU (harmonized NV 116/2016) Equipment for potentially explosive atmospheres (ATEX)

IECEx OD 009 

Operational Document

Standards used to assess the conformity of the electrical parts:
CENELEC EN IEC 60079-0

 

Explosive atmospheres – Part 0: Equipment – General requirements

EN 60079-7, IEC 60079-7

Explosive atmospheres – Part 7: Equipment protection by increased safety „e“

EN 60079-18, IEC 60079-18 

Explosive atmospheres – Part 18: Equipment protection by encapsulation „m“

FTZÚ 22 ATEX 0032X, IECEx FTZÚ 22.0004X

Non-electrical parts 
of valve

      I M2 Ex h I Mb
      II 2G Ex h IIC T4, T5, T6 Gb
      II 2D Ex h IIIC T135°C, T100°C, T85°C Db

Содержание RPEX3-06

Страница 1: ...erating instruction RPEX3 06 no 14054_1cz_03 2022 issued by the manufacturer 4 3 AND 4 2 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE DESIGNED FOR USE IN EXPLOSIVE ATMOSPHERES RPEX3 06 Operating instru...

Страница 2: ...Subject to change_RPEX3 06_14054_1en_03 2022 Page 2 www argo hytos com...

Страница 3: ...Subject to change_RPEX3 06_14054_1en_03 2022 Page 3 www argo hytos com...

Страница 4: ...Subject to change_RPEX3 06_14054_1en_03 2022 Page 4 www argo hytos com...

Страница 5: ...necting the valve to the hydraulic circuit 14 7 3 Commissioning 16 7 4 Normal operation 16 7 5 Extraordinary and emergency situations 16 7 6 Repairs carried out by specialist 17 7 6 1 Replacing a defe...

Страница 6: ...ppliance can be stopped Valves with ATEX certification according to Directive 2014 34 EU and IECEx certification according to IECEx OD 009 and related harmonized standards may be used in explosive atm...

Страница 7: ...control system perform a sliding motion in a space separated by a seal from the surround ing environment and flooded with working fluid Not exceeding the maximum surface temperature of the given temp...

Страница 8: ...it curves for each type of spool valve The hydraulic performance is provided as the product of the working pressure and the flow rate If the instant power exceeds the curve limit the valve may lose fu...

Страница 9: ...he maximum T channel pressure of 25 bar Without designation standard N7 with detent assembly N9 without emergency manual control 4 1 Emergency manual control Rozm ry v mm in 4 2 Materials used Valve b...

Страница 10: ...C 10 W 30 70 T4 135 C 18 W 30 60 T5 100 C 10 W 30 55 T6 85 C 10 W 30 45 IP68 test conditions product submerged 1m under water for 1 hour The coil with a nominal input of 18 W is intended only for dire...

Страница 11: ...perature and the application for the temperature class can be affected by adjusting the ambient temperature see 4 4Ambient temperature range for each class The coils with AC power supply and built in...

Страница 12: ...under the influence of drugs that have a demonstrable effect on attention and timeliness allergic to hydraulic working fluids WARNING Slippery valve surface The valve contains a small amount of resid...

Страница 13: ...depends on the cable diameter After mounting the valve it is necessary to ground the coil surface by connecting the ground wire to the terminal on the surface of the terminal cover using an M5x10 scr...

Страница 14: ...A UZ V PN W EX18 046 10W 12V DC 12 16 1 0 750 0 65 36 8 9 EX18 046 10W 24V DC 24 61 8 0 390 0 34 36 9 3 EX18 046 10W 48V DC 48 252 4 0 190 0 16 75 9 1 EX18 046 10W 110V DC 110 1171 5 0 094 0 08 180 1...

Страница 15: ...screw by 8 9 1 Nm 7 lbf ft M5x45 DIN 912 10 9 3 Grounding screw M5x10 5 1 Nm 3 7 0 7 lbf ft WARNING Correct installation of the valve The four sealing rings on the base of the body must be undamaged a...

Страница 16: ...PROTECTIVE EQUIPMENT When working with hydraulic fluid it is recommended to wear safety goggles protective rubber gloves and sturdy shoes with non slip soles 7 5 Exceptional and emergency situations I...

Страница 17: ...circuit see also 7 5 Lighten the hydraulic circuit including the accumulators by connecting it to the tank see also 7 5 Ensure that the hydraulic circuit is depressurised see also 7 5 Switch off the e...

Страница 18: ...supplied by the manufacturer We recommend using a new cable to connect the new coil Replace the sealing rings with new ones They are supplied in a set with the coil and a new fastening nut Put a new...

Страница 19: ...139600 EX18 046 10W 110V AC 8M 10 110 EX22 46 11050 10W8M B 42139800 EX18 046 10W 230V AC 3M 10 230 EX22 46 23050 10W3M B 42140700 EX18 046 10W 230V AC 8M 10 230 EX22 46 23050 10W8M B 42140800 EX18 04...

Страница 20: ...d k pou it RPEX3 06 slo 14054_1cz_03 2022 vydan v robcem D le it P ed pou it m v robku si pozorn p e t te n vod N vod k pou it uchovejte pro budouc pot ebu P i ztr t n vodu k pou it z sk te nov na web...

Страница 21: ...N vod k pou it _RPEX3 06_14054_1cz_03 2022 Strana 2 www argo hytos com...

Страница 22: ...N vod k pou it _RPEX3 06_14054_1cz_03 2022 Strana 3 www argo hytos com...

Страница 23: ...N vod k pou it _RPEX3 06_14054_1cz_03 2022 Strana 4 www argo hytos com...

Страница 24: ...veden do provozu 16 7 4 Norm ln provoz 16 7 5 Mimo dn a nouzov situace 16 7 6 Opravy prov d n osobami znal mi 17 7 6 1 V m na vadn ho ventilu 17 7 6 2 V m na t snic ch krou k na z kladn t lesa ventilu...

Страница 25: ...014 34 EU a IECEx podle IECEx OD 009 a n vazn ch harmonizovan ch norem sm b t pou ity ve v bu n ch atmosf r ch tvo en ch d ln m plynem plynem nebo prachem Ventily jsou ozna eny zna kou shody CE Ex a j...

Страница 26: ...ka kotva a kol k ovl dac ho syst mu konaj posuvn pohyb v prostoru odd len m t sn n m od okoln ho prost ed a zaplaven m pracovn kapalinou Nep ekro en maxim ln povrchov teploty dan teplotn t dy je podm...

Страница 27: ...od funk n ani po vypnut a do ochlazen na bezpe nou teplotu Hroz pop len poko ky VAROV N Pou it pracovn kapaliny Ventily sm b t pou ity pouze pro obvykl pracovn kapaliny zejm na hydraulick oleje viz ka...

Страница 28: ...n elektromagnety Je li rozv d ovl d n pomoc elektromagnet nepou vejte ru n nouzov ovl d n oup tka M e doj t k po kozen ventilu a ztr t jeho funkce 74 2 91 74 2 91 134 5 28 76 2 99 30 1 18 Nouzov ru n...

Страница 29: ...ol T4 135 C 10 W 30 70 T4 135 C 18 W 30 60 T5 100 C 10 W 30 55 T6 85 C 10 W 30 45 IP68 podm nky testu v robek pono en 1 m pod vodou po dobu 1 hodiny C vka se jmenovit m p konem 18 W je ur ena pouze pr...

Страница 30: ...ou it pro teplotn t du pravou teploty okol viz 4 4 Rozsah teploty okol pro jednotliv t dy C vky s AC nap jen m a zabudovan m usm r ova em jsou dod v ny pouze s p ipojen m kabelem standardn o voliteln...

Страница 31: ...nost a schopnost v asn reakce nadm rn nava pod vlivem l k maj c ch prokazateln vliv na pozornost a schopnost v asn reakce maj c m alergii na hydraulick pracovn kapaliny VAROV N Kluzk povrch ventilu Ve...

Страница 32: ...912 v ka svorkovnice a opatrn v ko sejm te Nepo ko te t sn n v ka O krou ek 45x2 4x roub M4x35 DIN 912 v ko svorkovnice Odstra te izolaci koncov sti kabelu tak aby po upevn n kabelu v pr chodce izolov...

Страница 33: ...46 10W 12V DC 12 16 1 0 750 0 65 36 8 9 EX18 046 10W 24V DC 24 61 8 0 390 0 34 36 9 3 EX18 046 10W 48V DC 48 252 4 0 190 0 16 75 9 1 EX18 046 10W 110V DC 110 1171 5 0 094 0 08 180 10 3 EX18 046 18W 12...

Страница 34: ...f ft Pr m r kabelu Upev ovac rouby 8 9 1 Nm 7 lbf ft M5x45 DIN 912 10 9 3 Zemnic roub M5x10 5 1 Nm 3 7 0 7 lbf ft VAROV N Spr vn mont ventilu ty i t snic krou ky na z kladn t lesa mus b t nepo kozen a...

Страница 35: ...EJTE OCHRANN POM CKY P i pr ci s hydraulickou kapalinou doporu ujeme pou vat ochrann br le ochrann pry ov rukavice a pevnou obuv s protiskluzovou podr kou 7 5 Mimo dn a nouzov situace P i v padku elek...

Страница 36: ...alinu porty kan l uzav ete p epravn deskou a zabalte jej tak aby b hem p epravy nedo lo k mechanick mu po kozen a kontaminaci prostoru mimo obal Zabalen ventil za lete s popisem projevu vady na adresu...

Страница 37: ...a novou up nac matic Nasa te na trubku nov t snic krou ek 22x1 5 novou c vku s p ipojen m kabelem nov t snic krou ek 21 89 x 2 62 a na roubujte novou up nac matici Matici dot hn te pomoc kl e momente...

Страница 38: ...46 11050 10W8M B 42139800 EX18 046 10W 230V AC 3M 10 230 EX22 46 23050 10W3M B 42140700 EX18 046 10W 230V AC 8M 10 230 EX22 46 23050 10W8M B 42140800 EX18 046 18W 110V AC 3M 18 110 EX22 46 11050 18W3M...

Отзывы: