Subject to change · FNA1HV 005_008_016_43622600 · 0421 · EN
Page 17
www.argo-hytos.com
10
Technical data
›
For device-specific technical data, please see table 8, page 19.
NOTE
FNA1HV 005
FNA1HV 008
FNA1HV 016
Nominal flow rate
5 l/min (50 Hz) or 6 l/min (60 Hz)
8 l/min (50 Hz) or 9.5 l/min (60 Hz)
16 l/min (50 Hz) or 19 l/min (60 Hz)
Pressure relief valve
5 ± 0.5 bar
Filter element
see page 18
Clogging indicator
on request, see page 18
Connections
see page 15 - table 6
Suction strainer
(optional)
fineness 600 µm
Electric drives
see page 18
FNA1HV 005 / 40050
3~ three-phase motor, 400/460 V, 50/60 Hz, 0.37/0.44 kW; n = 860/1030 min
–1
FNA1HV 008 / 23050
1~ AC motor with operating capacitor, 220-240 V, 50/60 Hz, 0.37 kW; n = 1500/1800 min
–1
FNA1HV 008 / 40050
3~ three-phase motor, 400/460 V, 50/60 Hz, 0.37/ 0.44 kW; n = 1500/1800 min
–1
FNA1HV 016 / 23050
1~ AC motor with operating capacitor, 220-240 V, 50/60 Hz, 0.55 kW/0.66 kW; n = 3000/3600 min
–1
FNA1HV 016 / 40050
3~ three-phase motor, 400/ 460 V, 50/ 60 Hz, 0.55/ 0.66 kW; n = 3000/ 3600 min
–1
Weight when empty
approx. 11 kg
Noise intensity level
max. 73 dB(A) under operating conditions allowed for continuous operation
max. 79 dB(A) under operating conditions allowed for short-term operation
Table 7 : Technical data