Subject to change · UMPC 045_31168300 · 0717 · EN
Page 25
www.argo-hytos.com
10.3 Pumping of hydraulic fluids (e.g. waste oil, filter is bypassed)
1. Connect the filter unit to a power source.
2. Insert the suction lance / suction pipe into the tank of the machine or system (e.g. hydraulic tank).
3. Place the discharge pipe into the container (e.g. empty oil barrel).
4. Move the lever to the "Pumping" position.
Fig. 16: Lever pumping / filtering
5. Switch on the filter unit at the on/off switch.
6. Check the oil flow (observe sufficient immersion depth of the suction lance in the hydraulic fluid).
NOTE
›
At the beginning of the filtration, filling of the filter unit may take several seconds.
Pumping
Filtering
7. Monitor the process.
8. After the machine or system has been completely emptied, switch off the filter unit at the circuit breaker.
9. Fix the suction lance / suction pipe and the discharge pipe to the corresponding brackets at the filter unit.