Subject to change · UMPC 045_31168300 · 0717 · EN

Page 23

www.argo-hytos.com

4.   Move the lever to the "Filtering" position.

Fig. 14: Lever pumping / filtering

5.   Switch on the filter unit at the on/off switch (circuit breaker).
6.   Check the oil flow for a possible insufficient insertion depth of the suction pipe in the oil tank.

               NOTE

 

At the beginning of the filtration, filling of the filter unit may take several seconds.

7.    Monitor the filling level at the machine or system and switch off the filter unit at the circuit breaker after having reached the     

  desired fill level.

8.   Fix the suction lance / suction pipe and the discharge pipe to the corresponding brackets at the filter unit.

10.1  Filtering of hydraulic fluids when refilling

1.   Connect the filter unit to a power source.
2.   Insert the suction lance / suction pipe into the oil barrel.
3.   Place the discharge pipe in a container (e.g. hydraulic tank).

               NOTE

Incorrect insertion of the discharge pipe

 

 Ensure that the discharge pipe is below the liquid surface.

Pumping

Filtering

Содержание Ecoline UMPC 045

Страница 1: ...n given does not release the user from his her own assessments and inspection Our products are subject to a natural wear and aging process All rights are reserved by ARGO HYTOS GMBH even in the event...

Страница 2: ...product 10 5 1 Component overview 10 5 2 Controls 13 5 3 Identification of the product 14 6 Transport and storage 15 6 1 Transport 15 6 2 Storage 15 7 Assembly 16 8 Commissioning 17 8 1 After switchi...

Страница 3: ...nt 32 11 4 Checking changing the suction filter element pump protection filter 32 11 4 1 Removing the suction filter 32 11 4 2 Installing the suction filter 32 12 Decommissioning 33 13 Disassembly 34...

Страница 4: ...d safety instructions symbols terms and abbreviations For better understanding these are explained in the following sections 1 3 1 Safety instructions In this documentation safety instructions are fac...

Страница 5: ...aning If this information is not observed the product cannot optimally be used or operated Singular independent action step instruction 1 2 3 Numbered instruction The numbers indicate that the action...

Страница 6: ...use described is improper and inadmissible If unsuitable products are installed or used in safety related applications unintended operating states may occur in the application which may cause personal...

Страница 7: ...sonal injury and or material damage Therefore only use the product in safety relevant applications if this use is explicitly specified and permitted in the product documentation You may only put the p...

Страница 8: ...premature wear or malfunction Make sure that connections hydraulic lines and attachment parts e g gauges are free from dirt and chips Prior to commissioning check that all hydraulic and mechanical co...

Страница 9: ...Subject to change UMPC 045_31168300 0717 EN Page 9 www argo hytos com 4 Scope of delivery This package includes 1 Filter and Recirculating Pump Unit UMPC 045 1 Operating manual...

Страница 10: ...0 Hose holder On both sides of the unit there are hose holders on which the pressure hoses suction and pressure side can be wound for better transport in case of non use Filter cover The housing cover...

Страница 11: ...ve humidity in the oil as well as the temperature and shows the degree of saturation with water Particle Monitor Oil The particle monitor OPCom allows a particle measurement according to the latest st...

Страница 12: ...is used to switch the unit from pumping mode to filtering Differential pressure switch This switch monitors the pressure of the medium before and after the filter Thus when the pressure difference is...

Страница 13: ...lights up as long as the unit is switched on Push button Reset This push button is used for reset in the event of a fault or in the case of an automatic switch off It must be actuated in order to rest...

Страница 14: ...7 EN Page 14 www argo hytos com 5 3 Identification of the product Serial number Type Manufacturing date encrypted Filter element type Fineness of the filter Nominal volume flow Maximum operating press...

Страница 15: ...tect it from humidity and condensation Fig 7 Transport rack The unit is mounted on a transport rack with two wheels This hand truck enables the unit to be transported without difficulty weight 97 kg e...

Страница 16: ...pe plate of the motor the power source has appropriately been secured 16 A the cross section is of sufficient size cable and connection to the power source are in perfect condition The following steps...

Страница 17: ...o prevent unintentional starting of the unit always switch off and unplug the unit 8 3 Venting To bleed the unit automatically loosen the black cap 3 on the ventilating valve 1 NOTE Do NOT unscrew the...

Страница 18: ...t red 4 Readiness indicator 5 Within the menu scroll up 6 Within the menu scroll down 7 Connection socket USB Type B 8 Slot for SD card 9 Canceling the current input back 10 Confirmation of a selected...

Страница 19: ...0 Power on screen During a brief initialization phase the display shows the version screen which provides information about the implemented software Fig 11 Start screen Fig 12 Initialization screen Af...

Страница 20: ...E A description of the installation and data transmission can be found in the OPCom user manual 1 Connect a data cable to the USB Type B jack Fig 9 Control panel on page 18 pos 7 2 Connect this cable...

Страница 21: ...ter line 2 Parameter line 4 Parameter line 3 Automatically off Brightness Contrast Time of day Date English Deutsch Fran ais Set flushing time Set pause time Set measuring time Set ISO Set measuring p...

Страница 22: ...uit has to stabilize air bubbles flushing etc The filter unit has a suction protection strainer on the suction side which must be serviced regularly A missing protective strainer can lead to the destr...

Страница 23: ...s 7 Monitor the filling level at the machine or system and switch off the filter unit at the circuit breaker after having reached the desired fill level 8 Fix the suction lance suction pipe and the di...

Страница 24: ...the filter unit at the circuit breaker 10 Fix the suction lance suction pipe and the discharge pipe to the corresponding brackets at the filter unit NOTE Achieving the maximum cleaning performance In...

Страница 25: ...ever to the Pumping position Fig 16 Lever pumping filtering 5 Switch on the filter unit at the on off switch 6 Check the oil flow observe sufficient immersion depth of the suction lance in the hydraul...

Страница 26: ...EFORE filter Fig 18 Three way valve 6 Switch on the filter unit at the on off switch circuit breaker and let it operate for approx 5 min Initialization of the particle counter and ventilation of the s...

Страница 27: ...ginning of the filtration filling of the filter unit may take several seconds 4 Move the lever to the Filtering position Particle Counting Filling AFTER filter Particle Counting Cleaning BEFORE filter...

Страница 28: ...he cleanliness classes must be reached three times for shut down Only then the device switches off automatically Fig 22 Automatic active After the initialization screen page 19 Fig 12 has been display...

Страница 29: ...om By pressing the Hook button the auxiliary screen is deleted and the normal menu with the addition SUCCESSFUL appears Fig 24 Additional display By starting the pump mode 1 is automatically activated...

Страница 30: ...ANGER Danger to life Risk of electric shock During repair work turn off the unit and pull the mains plug NOTE Impaired function by dirt ingress into the pump The function of the filter unit is no long...

Страница 31: ...the cover 1 Push the filter element at the cover in arrow direction 1 and remove it in arrow direction 2 2 Dispose of the filter element according to the national environmental legislation Waste code...

Страница 32: ...suction filter element pump protection filter 11 4 1 Removing the suction filter Fig 29 Removing the suction filter 1 2 3 4 11 4 2 Installing the suction filter 1 Always replace the sealing ring 3 aft...

Страница 33: ...045_31168300 0717 EN Page 33 www argo hytos com 12 Decommissioning The filter unit UMPC 045 is a component which does not have to be taken out of service Therefore the chapter in this manual does not...

Страница 34: ...Subject to change UMPC 045_31168300 0717 EN Page 34 www argo hytos com 13 Disassembly This chapter does not contain any information for your device...

Страница 35: ...s disposal of the filter unit UMPC 045 and the pressurized fluid can lead to environmental pollution Therefore dispose of the filter unit and the pressure fluid according to the national regulations o...

Страница 36: ...arranty of ARGO HYTOS applies to the delivered configuration and extensions which were taken into account during configuration The warranty expires after a conversion or extension that goes beyond the...

Страница 37: ...stem in which the particle monitor OPCom Portable is installed Have the operating conditions or the area of application of the particle monitor OPCom Portable been changed Have modifications e g conve...

Страница 38: ...ning Max dirt capacity of the filter element is reached Leakage at the suction hose falsification of the measurement results by free air in the oil air bubbles Rotary valve on lever position Pumping R...

Страница 39: ...Subject to change UMPC 045_31168300 0717 EN Page 39 www argo hytos com Fig 30 Dimension drawing 17 Technical specifications 17 1 Dimension drawing...

Страница 40: ...Connection G with hose DN 32 and suction lance when replacing the suction hose only use a spiral hose Pressure side Connection G1 with hose DN 25 and pressure lance Suction strainer Screen element 28...

Страница 41: ...ination of the cleanliness class is possible in a viscosity range of 15 mm2 s to 250 mm2 s Electric drive 3 400 V 50 60 Hz mm2 s min continuous operation mm2 s max continuous operation 15 600 An exact...

Страница 42: ...r Unit UMPC 045 Wir best tigen die bereinstimmung mit den wesentlichen Anforderungen der europ ischen Richtlinie n Maschinenrichtlinie 2006 42 EG EMV Richtlinie 2004 108 EG We confirm the conformity a...

Страница 43: ...g 1 Fig 33 Spare parts drawing 2 Housing Cover complete O ring Equipment rack Hose Fixture Flat headed screw ISO 7380 Motor Wheel RAM 250 88 Hubcap Filter element Screwing Screwing Hose Valve complete...

Страница 44: ...er supply complete not shown Fig 35 Spare parts drawing 4 Pressure relief valve Locking ring Valve complete Hose Clamp Pipe Screwings Hose Clamp Pipe LubMon Visu Ball valve Hose complete Block complet...

Страница 45: ...3532100 M8x70 not shown 16 Valve complete 1 17711200 17 Hose 2 17505401 18 Filter element 1 V7 1560 103 3 m c 19 Screwing 1 17256700 20 Screwing 1 17256800 21 Screw plug DIN 908 1 13526600 22 USIT rin...

Страница 46: ...e ARGO HYTOS SARL info fr argo hytos com Germany ARGO HYTOS GMBH info de argo hytos com Great Britain ARGO HYTOS Ltd info uk argo hytos com Hong Kong ARGO HYTOS Hong Kong Ltd info hk argo hytos com In...

Отзывы: