Subject to change · 40719700 · 1217 · EN
Page 26
www.argo-hytos.com
Table 8: Technical data
16.1 Technical data
Nominal fl ow rate
l/m (50 Hz)
2.5
Pressure limiting valve
bar
3.5 ± 0.5
Max. operating pressure
bar
4
Filter element
CFP 03-13
V3.0510-53
ß
5(c)
=
200
CFP 03-16
V3.0510-56
ß
10(c)
=
200
CFP 03-18
V3.0510-58
ß
16(c)
=
200
Clogging indicator
Pressure gauge DG 200-17
green: 0 - 2.5 bar
red:
2.5 bar and up
Suction strainer - mesh size
µm
700
Suction side
Hose DN 8, length 2.2 m
Pressure side
Hose DN 8, length 2.0 m
Electric drive
1 ~230 V Motor; 50 Hz;
0.06 kW, n=1,450 min
-1
CFP 03-13
,
CFP 03-13, CFP 03-18
Weight
kg
approx. 9
Sound power level
db(A) max.
65 (under operating conditions permitted for continuous
operation)
70 (under operating conditions permitted for short-term
operation)
Dimensions (L x W x H)
mm
300 x 270 x 265
Fig. 16: Device dimensions
16. Technical data
16.2 Device dimensions