Subject to change · 40719700 · 1217 · EN
Page 14
www.argo-hytos.com
8. Commissioning
8.1
Before commissioning
›
Ensure cleanliness during installation in order to prevent debris such as welding beads or metal shavings from entering the
hydraulic lines and causing wear and malfunctions in the product.
›
Make sure the connections, hydraulic lines and fittings are free of dirt and chips
›
Prior to commissioning, verify that all hydraulic and mechanical connections are connected and tight, and that all of the
connectors' gaskets and screw connections are correctly installed and undamaged.
›
Use residue-free industrial wipes in order to remove lubricants and other contamination.
›
Make sure that the connections, hydraulic lines and fittings are clean.
›
Make sure that no contaminants penetrate while closing the connections.
›
Make sure that no cleaning agents enter the hydraulic system.
›
Do not use steel wool or fraying cloths for cleaning.
8.2 Commissioning
1. Remove the plugs from the free ends of suction and pressure hose.
2. Place the suction and discharge hose in the oil container. Make sure that they are immersed far enough below the liquid level.
3. Connect the voltage plug with the 1-phase socket.
4. Turn the filter unit on using the ON/OFF switch (circuit breaker).
8.3
After switching on
1. Check the filter unit for leaks.
8.4
Working with the additional return-suction set
1. Install the return-suction adapter in the oil tank.
2. Remove the plugs from the free ends of the suction and pressure hose.
3. Connect the suction and pressure hose to the appropriate quick couplings of the adapter.
4. Connect the voltage plug of the 1-phase socket.
5. Turn the filter unit on using the ON/OFF switch (circuit breaker).
8.5
End of operation
1. Turn the filter unit off at the ON/OFF switch (circuit breaker).
2. Unplug the power cord.
3. Remove the suction and pressure hose from the oil container.
4. In case of working with a return-suction adapter remove the adapter from the tank.
5. Clean the hoses and attach the hose plugs to free ends of the hoses.
6. When the device ends working, drain off the residual oil into a separate container.
8.6
Change of oil type
Prior to pumping another kind of oil:
1. Remove the filter element.
2. Clean the unit from the residual oil.
3. Install the new filter element in the housing.
4. Pump the oil into the target container.
8.7
In case of power failure
In order to prevent unintentional starting of the unit, always switch off and unplug the unit.